Validering av vattenkraftmodeller i ARISTO

This master thesis was made to validate hydropower models of a turbine governor,Kaplan turbine and a Francis turbine in the power system simulator ARISTO atSvenska Kraftnät. The validation was made in three steps. The first step was to makesure the models was implement correctly in the simulator. The second was tocompare the simulation results from the Kaplan turbine model to data from a realhydropower plant. The comparison was made to see how the models could generatesimulation result that was similar to the reference power station.

Modell och analysverktyg för beräkningav frekvensförlopp

The power system modelled in this thesis work has been developed for simulationwhen e.g. the production in some part of the power system is changed. The powersystem has been modelled according to the swing mass of the system, the frequencydependency of the load and the turbine governor. The model determines the systemfrequency, the period of regulation and the power exchange between the differentsubsystems in the Nordic synchronized system.In this model the system frequency is assumed to be the same in all different parts ofthe power system and the voltage conditions in the power system are neglected. Forthat reason power swings does not occur between different subsystems in the powersystem, which usually occur as a result of the swinging connection between thetransmissions line.

Modellering av reserv- och nödkraftsystem i JAS 39 Gripen

Simulation is a vital tool during development of JAS 39 Gripen, since money and time can be saved.The Auxiliary and Emergency Power System, AEPS, is a subsystem of the secondary power system in Gripen. It has the function of providing the aircraft with electrical and hydraulical power before activation and after deactivation of the main engine. The system also functions as backup in case of a safety critical problem in the main power supply system. The system basically consists of a control unit and an auxiliary gearbox. The gearbox is driven by an air turbine.

Environment simulation of track-based systems

Simulation means running a model of a system with suitable input and observing the corresponding output. Real-time environment simulation is a special kind of simulation used to simulate a control system's environment in real-time. This is done to test the control system before it is used in its real environment. In this project, computer simulation of a certain kind of environments, called track-based systems, is studied and a general model for track-based systems is developed. In this model, track layouts are represented by graphs, which is a flexible and extensible representation and a method for visualizing these layouts is presented.

Jämförande simulering och modellering av framtida järnvägars elenergiförsörjning

In this thesis, the Train Power System Simulator (TPSS) has been compared and verified with the commercial simulator TracFeed® Simulation (TracFeed). The basis for the comparison was a given part of the Swedish railway system, with steel transportation trains. Primarily, emphasis was placed on running time and energy consumption in simulation results. Two transformer systems were analyzed, booster and auto transformers. The high voltage transmission line, parallel to the railroad track, was disconnected in some simulations.

Frekvensreglering i det nordiska kraftsystemet

Svenska Kraftnät is (together with the other transmission system operators of the Nordic power system) responsible for keeping balance between the generated and demanded power in the Nordic power system. Spontaneous load variations and system disturbances, however, lead to power imbalance followed by frequency variations. The frequency deviations can be limited to an acceptable level by the spinning reserve, mainly by hydro power control. But there are also other system properties which have a great influence on the frequency and system stability. The frequency and voltage dependence of the loads have a direct influence on the power balance.

Hur enkel- & dubbelportsturbin i kombination med två olika avgassamlare påverkar gasväxlingsprestanda på en Scania V8

The exhaust arrangement on a Scania V8 consists of one manifold at each bank connected to a twin entry turbine (8-2-2). A study in GT-Power has shown improved performance and reduced cylinder to cylinder variations using two manifolds at each bank in combination with a single entry turbine (8-4-1). This thesis work analyses the difference in performance shown in simulation and verify it by engine test.The initial work was focused on simulation in GT-Power. Investigating how exhaust manifold volume and pulses effects the turbine efficiency and the mean effective pressure during the gas exchange. To verify GT-Power simulations four engine tests with different exhaust arrangement have been made.The results from GT-Power simulation indicate that a larger exhaust volume improve the turbine efficiency.

Åsktransienter och överspänningar : En spänningsfylld simulering av elkraftsystemet vid Forsmark 3

A power system will inevitably be subjected to transient overvoltages, most often produced by switching operations and lightning strikes. These transient overvoltages may harm sensitive equipment without sufficient protection, but it is not an easy task to predict what transients may occur or how they affect the system. A fault occurred in a low voltage system at Forsmark 2012 and overvoltages from lightning were concluded as the probable cause. The three aims with this thesis are to develop and test a model of the power system at Forsmark 3, analyse the transient behaviour of the system when subjected to lightning surges and identify critical parameters, and lastly to provide a tool for investigating the protection of the system. The modelling and simulations were performed in the freely available simulation program LT Spice.

Implementering av en PSS i Trängslets kraftstation

The purpose of this master thesis is to implement and validate a Power System Stabilizer (PSS) to a generator at Trängslet hydropower station in Dalarna, Sweden. Problems with local rotor oscillations can occur at the hydropower station when power is transferred on a new power line (130 kV) from Northern to Southern part of Dalarna. To ensure good operation properties on this power line Fortum Generation AB and Fortum Distribution AB wants to activate a PSS on a generator.There have been investigations in which situations and what equipment that contributes to rotor oscillations. When this is known the PSS is tuned to damp these oscillations by choosing a good set of parameters. The most important parameters for good performance are to choose amount of gain and phase compensation.

Avbrottsfri Kraft med användning av ultrakondensatorer

The supply of uninterruptible power can be applied to many areas wherecontinuous operation is highly prioritized.The application of uninterruptible power for motor operation is facilitatedusing a frequency converter. Direct current operated frequency converters canbe applied directly to the power reserve which removes the need for additionalpower-converting.Batteries have long constituted the power reserve but advancements inthe development of ultracapacitors have created a viable substitution. Ultra-capacitors have high energy storing capabilities and can be applied to highpower applications.Maxwell is a leading manufacturing company of ultracapacitors and pro-vide different modules with built-in solutions for voltage balancing. Unevenvoltages between series-connected capacitors is a phenomenon caused by vary-ing capacitance. A configuration containing Maxwell?s 56V module is createdand constitutes the power reserve in the simulations.The discharge simulation shows a significant current that could damagethe system.

Design och tillverkning av en stereoanläggning med aktivt delningsfilter

This thesis is the result of the author?s interest in music and electronics, namely the design and manufacturing of a stereo sound system with an active crossover. In short it can be stated that an active crossover has many advantages over its traditional passive counterpart. The active design naturally results in a more complex system comprised of a multiple number of components. This report deals with the theoretical aspects of preamplifiers, crossovers and power amplifiers as well as power supply and control.

Modellering av Panna 5 Mälarenergi AB : utveckling av en beräkningsmodell med simuleringsverktyget IPSEpro

Heat and power stations are often in need of optimizations. A simulation model is a tool for findingways to optimize the plant. The scope of this diploma work is to develop a simulation model ofBoiler 5 at Mälarenergi AB. Boiler 5 is a circulated fluidized bed boiler that was taken into service inyear 2001. Among the included parts in the boiler are cyclone, convection part andINTREX-chambers.

Avancerad scenarioanalys för ambulansplanering

This paper describes the development of a simulation model for the ambulance flow in the Västra Götalands-region of Sweden, and an analysis tool for the output of the simulation model. The aim of the simulation model was to be able to evaluate the outcome from changes in the ambulance operations, such as a reorganization of ambulances or an increase in intensity of the ambulance calls. This evaluation is meant to serve as decision support for the strategic planning of the ambulance operations. The analysis tool was developed to visualize the abundant geographical data produced by the simulation model in a meaningful way. The simulation model was validated against historical data which showed that the dispatch time for the highest prioritized ambulance calls corresponds well with historical data.

Lane Keeping Aid : ett förarstödjande system för bilar

Many traffic incidents are due to the driver?s lack of attention, resulting in dangerous lane departures, either sliding off theroad or into the oppose lane. These kinds of incidents often have serious outcomes, which has led to much effort being concentrated on preventing or lessening the damages when the incident is already a fact, for example by installing safety belts and air bags. These measures may be considered to be acts of so-called passive safety. Active safety on the other hand, means that the safety systems intervene before the incidents have occurred.

Utveckling av en dynamisk Simuleringsmodell av en skotare

The predominant forestry harvesting method is based on the harvester-forwarder method, theharvester folds, branches and cuts trees, and sorts the logs into piles, while a forwarder transportsthe logs to a landing area.This master thesis work is about realization of a dynamic forwarder simulation model, and itspurpose is to provide an integrated forwarder simulation model in MATLAB/SimMechanicswhere the forwarder is based on a concept using pendulum arms to connect wheels and chassis.Active suspension control is developed and implemented into the simulation model, and finallycompared in simulation with passive suspension.In a first step, an integrated forwarder simulation model is developed, containing a simplifiedforwarder model, a tire-to-ground interaction model and a test track model. The simplifiedforwarder model is based a rigid multi-body system with a spring-damper suspension of thependulum arms. The tire-to-ground interaction model calculates the reaction forces, friction fromthe ground and applies the propulsion force. The test track model is a simplified version of thereal test track in Skogforsk. The propulsion wheel torque control is used to regulate theforwarder speed.