Sökresultat:
1226 Uppsatser om Heat loss - Sida 5 av 82
Miljöbetong
The study aims to reduce energy consumption in apartment buildings where individual metering and charging of heat is applied. The aim is to develop planning and design for individual metering and charging in apartment buildings.The study is based on literature review, interviews and case study that include analysis of existing documents. Interviews were carried out with the property developer and the involved consultants who planned the apartment building Yasuragi. To investigate the differences the condominium association has noted in heat consumption between flats, the debit values of the heat were used to discern which houses that were furthest from the average consumption. On these flats there were temperature measurements and thermal photo shoots made for discriminating behavior and possible construction techniques which could be the explanation for the heat spread.Boverket shows that the consumption of heat can be reduced by 10-20% after insertion of individual metering and charging in an apartment block.
Ljudreducering av värmepump
This degree project handles acoustic measurements of the heat pump EcoAir 107, made by Enertech CTC AB. The sound from the three sound sources of the heat pump, fan, compressor and four way valve, have been measured to find out how they affect the total sound level of the product.Measures to attenuate the sound level have been developed and tested. By comparing these with the sound of the heat pump, in its original state, we have found out the measures which have best effects.The best attenuating measures came to be: taped openings and holes around the compressor space, isolating the top and the bottom of the whole construction, support of the fan bottom part and shielding of the sound source with a screen at a distance of 110 mmThese measures have been tested together and an average attenuation of the total sound level with 3,9 dB have been accomplished. In the front of the fan where the continuous sound is the strongest, the attenuation was 4,7 dB.This project is meant to be used as a guide by Enertech CTC AB:s during their future developing process..
Familjen & Döden : föräldrars förhållningssätt till sina kvarvarande barn
The aim of this study was to explore the role of death in the Swedish family. How do parents and families cope with the loss of a child/sibling? How do the remaining children in a family fare after loss of sibling? The study was caused out partially through a selective review of the literature on children loss in families and partially through interviews with families who had experienced death of a child. The results were analysed with help of Family system theory, Emotional theory and with an Esoteric perspective. The findings of the study were that although families do eventually cope with the situation the majority is struggling to adjust.
Identitetsutveckling och delaktighetsprocesser med stöd av internet -En beskrivande litteraturstudie om tonåringar med hörselnedsättning
A hearing loss may affect the identity development and participation among adolescents. To understand adolescents with hearing loss in modern society, it?s of great importance to ascertain how identity- and participation processes occur in new areas, such as the internet.Objective: The aim of this study was to investigate what research shown regarding identity development among adolescents with hearing loss and whether social processes on the internet may influence the participation of this group.Method: A literature review was conducted to obtain a cohesive framework of research about participation processes and identity development among adolescents. Included articles have been published 1995-2015.Results: The results show the importance of the individual?s identification with the surrounding.
GNSS-Styrning : Information för platschefer
An investigation of the heat impact of laser cutting on the material properties when producing tensile and impact test specimens of different steel types of varying thickness has been performed. The purpose of the thesis project was to provide recommendations regarding how much material that needs to be milled from the laser cut edge before tensile and impact tests. The study has been performed partly by investigating the test specimens by heat camera when the specimens were cut in the laser cutting line and partly by performing hardness tests, investigation by microscopy, and tolerance and roughness measurements and tensile tests of the laser cut material and material produced in the traditional multi operation machine. The results show that the heat affected zone in the thicker materials is greater than previously thought of, and that the currently used recommendation has to be adjusted. The study clearly shows that the thicker the material, the greater the heat affected zone, independently of the steel type, since the thicker material takes longer time to cut.
Energianvändning för markkonstruktioner förlagda med ytvärme : En teknisk och ekonomisk utredning av fördelarna med att isolera under värmerören
The need for snow-free surfaces at squares, bus stops, platforms, car parks and sports facilities increases and at the same time energy price rise and the environment is becoming a hotter issue. The construction of the ground heating systems often lack thermal insulation under the heating pipes, which means that the heat from the pipes not only warm up the soil surface but also heats the surrounding soil. The insulation also has more features, by insulating the risk of frost damage is minimized. The goal of this report is to demonstrate the large Heat loss and energy costs in the absence of insulation under the heating system.The report begins with a scientific way to study and treating the soil heating system uses, and the theory involved. Furthermore it also deals with different routing principles of heat pipes depending on the facility.All calculations are made with so called finite element method (FEM), in COMSOL Multiphysics 3,5a, where models are created with different conditions.
Energikartläggning av avfallsförbränningen i Uppsala
Vattenfall Heat Uppsala runs the waste incineration plant in Uppsala, which produces district heating, process steam, district cooling and electricity. Vattenfall Heat Uppsala has decided to introduce an energy management system with the aim to increase the energy efficiency of the plant. The basis in such a system is to make an energy mapping.In this thesis an energy mapping has been performed at the waste incineration plant with the aim to identify and determine the size of energy flows. The investigated energy flows are used fuel, produced and used steam, produced district heating and cooling. Also the use of electricity to run the processes has been investigated.
Småskalig biobränsleeldad kraftvärmeproduktion : teknik och investeringsutrymme
To achieve the requirements to decrease emissions of greenhouse gases by 20 % by 2020, Swedenneeds to increase its use of bioenergy. In doing so it seems natural that those who already haveaccess to large amounts of biofuels in the form of by-products such as straw, wood chips anddigestible materials take advantage of these assets locally. By combining production of heat withpower production at the farm it may be possible to not only reduce the direct use of fossil fuel forheating but also reduce energy costs.The purpose was to simulate different cases of using a small scale biofueled combined heat andpower plant for farm-based systems. A MatLab-model was developed and used to draw conclusionsabout the costs for production of heat and electricity with different conversion technologies.The model uses climate data to simulate the variations in heat energy demand on a day-to-day basis.The given heat demand is the base of the simulation and from this the possible electric output iscalculated. This study has focused on the impact of the following properties: electric-, heat- andtotal efficiency, fuel, fuel price and specific fuel requirements.
Vibrationsdämpning av värmepump
Thermia Värme AB is one of the market leading manufactures of heat pumps. In order tomaintain this position, the company wants to improve the vibration characteristics of theirproducts. The aim of this thesis is to develop product design changes that lead to a reductionof vibrations in the heat pump Thermia Diplomat 8.The main cause for vibrations in the system is flow pulsation and mechanical forces inducedby the scroll compressor. Vibration is transmitted through the compressor piping and receivedby the heat exchangers, from where it is further transmitted to the connection points for theradiator and heat source circuits.A number of design changes in order to improve the vibration characteristics have beenevaluated through calculations and practical experiments. The changes have included thecompressor and heat exchanger mountings, the compressor suction and discharge line pipingand also pulsation dampening.The results of the experiments show that the vibration levels in the connections for the heatingand brine circuits can be decreased strikingly through changes in suction and discharge linepiping.
Studie av skyddsavstånd mellan bergvärmeanläggning och skyddsobjekt i ett vattenskyddsområde
During installation and operation of a geothermal heat pump system leakage of an antifreezing agent can appear in a borehole and leak out in surrounding groundwater. To guarantee high quality drinking water for generations to come Sweden has dedicated some areas as water protection areas. The local authority gives permits for the installation of heat pump systems within water protection areas. Before giving a permit the local authority makes an evaluation of the risks involved in installation and operation of the system within the area. By keeping a certain distance between the protected object in the area and the heat pump system the risk of polluting the protected object with an anti-freezing agent can be reduced.This thesis makes a comparison between three different methods of calculating an appropriate distance between the protected object and the heat pump system.
Energy analysis of a fruit drying plant in Adeiso, Ghana
The purpose of the project has been to work out recommendations that reduce the energy-related costs and environmental impact of HPW Fresh & Dry Ltd., a fruit
drying factory in Ghana. The factory produces electricity with diesel and biogas but also purchases electricity from the national electricity company. Heat for the drying
process is produced from biogas, kerosene and solar panels. In the project the energy system was analyzed by measuring production and consumption of heat and electricity.
The project results show that the factory can become self-sufficient on heat if the available energy is used more efficient. The production units for both electricity and heat have low efficiencies.
Sapa Heat Transfers koldioxidspår : En kartläggning av verksamhetens koldioxidutsläpp
Sapa Heat Transfer is a company that produces aluminum heat-exchanger strips for the automotive industry. Sapa Heat Transfer wish to chart their emissions of carbon dioxide in order to meet future demands on carbon dioxide reporting. They also would like to examine the meaning of the term ?green electricity? which is marketed as carbon dioxide free, and the sort of electricity that they purchase. This report includes both direct (liquefied petroleum gas and diesel) and indirect (water, process-water, long distance heating, waste) emissions from their company.
Hörselnedsättning hos barn och ungdomar till följd av platinabaserad kemoterapi - en beskrivande litteraturstudie
Success in treatment with platinum-based chemotherapy against different types of cancer tumors is limited by side-effects such as hearing loss which can have a large impact on the individual`s quality of life. It is of great importance to continue with studies that address this complex of problems.Objective: The aim of this literature review is to investigate the impact of platinum-based chemotherapy on hearing in children and adolescents treated for different types of cancer.Method: A descriptive review of literature was made based on sources from 15 different studies on the impact of platinum-based chemotherapy on hearing in the target group.Results: The survey of the studies shows that platinum-based chemotherapy causes incidence of hearing loss by differing degree in the target group. Dosage of a platinum-based substance appeared to be the most significant factor. Treatment with both cisplatin and carboplatin was more ototoxic than treatment with only one of these. Greater risk for hearing loss was to a higher degree observed in younger children.
Planering och projektering för individuell mätning och debitering i flerbostadshus
The study aims to reduce energy consumption in apartment buildings where individual metering and charging of heat is applied. The aim is to develop planning and design for individual metering and charging in apartment buildings.The study is based on literature review, interviews and case study that include analysis of existing documents. Interviews were carried out with the property developer and the involved consultants who planned the apartment building Yasuragi. To investigate the differences the condominium association has noted in heat consumption between flats, the debit values of the heat were used to discern which houses that were furthest from the average consumption. On these flats there were temperature measurements and thermal photo shoots made for discriminating behavior and possible construction techniques which could be the explanation for the heat spread.Boverket shows that the consumption of heat can be reduced by 10-20% after insertion of individual metering and charging in an apartment block.
Bakomliggande faktorer till presbyacusis; en litteraturstudie av mindre kända faktorer
Audionomprogrammet.