Sök:

Studie av skyddsavstånd mellan bergvärmeanläggning och skyddsobjekt i ett vattenskyddsområde


During installation and operation of a geothermal heat pump system leakage of an antifreezing agent can appear in a borehole and leak out in surrounding groundwater. To guarantee high quality drinking water for generations to come Sweden has dedicated some areas as water protection areas. The local authority gives permits for the installation of heat pump systems within water protection areas. Before giving a permit the local authority makes an evaluation of the risks involved in installation and operation of the system within the area. By keeping a certain distance between the protected object in the area and the heat pump system the risk of polluting the protected object with an anti-freezing agent can be reduced.This thesis makes a comparison between three different methods of calculating an appropriate distance between the protected object and the heat pump system. These methods include different numbers of parameters to calculate the appropriate distance.The results are evaluated with regard to the parameters used. The methods used are a simplified version of an empirical point-count system made by LeGrand, an analytical solution from Baetsle and a numerical solution with Visual MODFLOW 4.0.

Författare

Maria Wikström

Lärosäte och institution

Uppsala universitet/Institutionen för geovetenskaper

Nivå:

"Uppsats för yrkesexamina på avancerad nivå". Självständigt arbete (examensarbete) om 30 högskolepoäng utfört för att erhålla yrkesexamen på avancerad nivå.

Läs mer..