Sök:

Sökresultat:

807 Uppsatser om Wind measurement - Sida 14 av 54

Volymmätare för tall- och grankott

This thesis describes the planning and development of a volume meter of pine and spruce cones. The product was designed and developed for Stigsjö Skog och Frö AB in Härnösand. It was developed taking into account a number of requirements set by the supervisor David Zetterlund. The main requirements were that the volume measurement would be fast and give accurate results. These are two requirements that are missing in today's volume measuring method which is very problematic for the company.The plant was visited several times in Härnösand, mainly to discuss the generated concepts with the supervisor and perform tests on the prototype.

Modeller för studier av ursprungsmärkt el

The EU has decided that it should be possible for consumers to get information about the origin of the electricity they buy. Therefore, there is a need to examine different systems for electricity disclosure. In this thesis two ways of disclosure have been studied:? Certificate system. A certificate system involves two parallel markets, one for trading electrical energy and one for trading certificates of origin.? Separated Markets.

Tillväxtreaktion hos skärmträd i högskärm av gran i Medelpad :

Different methods for shelterwood cutting have been used in differ-ent parts of Europe since the middle ages. The use of shelter wood cutting in Norway spruce (Picea abies (L.) Karst.) forests in Sweden met a revival in the early 1990s as an alternative for the dominating clear-cutting system when silvicultural costs increased dramatically for the latter. Shelterwood cutting systems involve some possible problems but also a lot of positive effects. Among the problems are increased risk of wind throw and damage of the remaining shelter trees caused by the cutting operation. Positive effects are for example a valuable growth in the remaining trees and increased biological di-versity. This study is based on a total of 79 trees from 4 different treatments in a spruce shelterwood, cut in 1994, in the middle of Sweden (62,4º N).

Evaluation of four methods for the assessment of joint swelling in dogs

Evaluation of joint swelling is an important part of the orthopedic examination and can be used to follow a patient?s progress during rehabilitation and therapy. Usually a swelling is assessed by palpating the joint but a more objective, but still easy to use, method would be preferable.This study seeks to increase the knowledge in veterinary rehabilitation by validating four different measurement tools (three recognized and one novel) for the assessment of elbow joint swelling: palpation, tape measure (circumference and figure eight measurement), slide caliper (craniocaudal and mediolateral positioning) and tonometer. This was achieved by calculating the inter- and intra-rater reliability and correlating the results from the different measurements with each other.The methods with best inter- and intra-rater reliability as well as good correlation among themselves were shown to be slide caliper with craniocaudal positioning, circumference and figure eight. Additional studies, with a larger and more diverse material, ought to investigate these methods further..

Initial evaluation of the Meritas Troponin I test for measurement of equine cardiac troponin I

Cardiac troponin I (cTnI) is considered a specific and a sensitive biomarker of cardiac disease, and due to a high inter-species sequence homology; human cTnI assays can often be used in veterinary medicine. The main aim of this study was to perform an initial evaluation of a human cTnI test, the Meritas Troponin I test, for measurement of equine plasma cTnI, in order to investigate whether the test could be a possible subject for a more comprehensive validation. The hypothesis was that the test could measure equine cTnI, as there is a good homology between equine cTnI and human cTnI. The evaluation included a dilution parallelism, an intra-assay precision study and measurement of plasma cTnI healthy horses. In the dilution parallelism and the intra-assay precision study, equine plasma with previously established high cTnI concentration, according to another cTnI assay, was used. In addition, cTnI concentration was measured in plasma, collected from 19 horses, without signs of disease at physical and ECG examinations. The obtained curve in the dilution parallelism was linear, indicating that the Meritas Troponin I test can be used to measure different concentrations of equine cTnI in plasma.

Examenskonserten - Är den utvecklande?

Den 31 mars 2006 genomförde jag min examenskonsert ackompanjerad av Spårvägen Malmö. Efteråt började jag fundera på om orkestern fick ut lika mycket av själva konserten och förarbetet som jag. För att ta reda på detta genomförde jag en enkätundersökning med orkestern samt intervjuer med utvalda musikanter. Arbetet tar upp relationen mellan amatörer och professionella och hur man väljer repertoar i en amatörorkester. I resultatkapitlet redovisar jag enkäten och intervjuerna.

Avståndsvarnare till Mobiltelefon

This report describes a study, description and testing of parts to an application adapted to the operating system Android. The application is supposed to measure the distance to a car ahead. Apart from distance measurements the ability of the application to calculate its own speed with the help of GPS is tested. From these two parameters, speed, distance and some constants the theoretical stopping distance of the car will be calculated in order to warn the driver if the car is too close to the car ahead in relation to its own speed and stopping distance.Tests were conducted on the different applications that were programmed and the result showed that the camera technique in the mobile phone itself limits the maximum distance of the distance measurement application. The max distance the tests in this thesis revealed was approximately 5 meters.

Lantbrukaren som energiproducent : en fallstudie i energisatsningar inom lantbruket

The intrest and development of bioenergy and energy from renewable sources in Sweden has increased rapidly over the last few years. There are a whole lot of alternatives for those who would like to venture and invest in renewable energy production. Production of renewable energy opens up many opportunities for forestry and farming to venture a new branch of production, on basis of the primary production. Several of the new energy sources grows on farmland or in the forest. The opportunities exist in the primary products, as well as in refining and reselling, in the value chain of energy. The starting-point is the Farmer as an energyproducer. This master thesis studies the nature of farmer-own firms, who has invested in production of renewable energy.

Mätning i nätstationer - nyttor och problem

The purpose of this study has been to investigate advantages and problems with distributionsystem metering in substations. This report is a study in cooperation with Göteborg Energi.The analyses in this report are made for GENAB, a subsidiary company of Göteborg Energi.To analyse advantages and problems in advance is interesting information for GENAB. Theresult of the report could be based upon whether installation of metering in distributionsubstations will be implemented and in that case which kind of measurement that is relevant.The most relevant and strategic place to implement measurement is at the distributionsubstations on the secondary side (400V), this is due to the placement of the currenttransformers. The measurements in this study involve current, voltage, power, power factor,temperature, energy and power quality.Measuring instruments that are relevant to implement are intended to measure current,voltage, power, power factor, energy and, possibly, power quality in the same measuring unit.It is desirable to have a measuring instrument that measures both energy and power qualitybut since it is most often a cost question, it can be established that energy meters have a lowercost.Metering in distribution substations gives a better illustration of the power network. Thisresults in many advantages for GENAB.

Vindfällning i naturliga och skapade bryn och kanter :

The aim of this work was to study if the edge of the forest is more resistant to heavy winds than the trees located further in from the edge, and how this edge effect changes between different types of tree species and site types. The data was collected from an electric power line going from the north to the south of Sweden. The mean value of the clearcutted area around the power line was 120 meters. The main direction of the storm in January 2005 was west-southwest and thus the power line was a perfect place for gathering a large data set. The main parameter studied was the damage frequency at the edge of the forest compared to the trees located further in from the edge (up to 100 m from the power line). Tree species mixture, soil moisture class, soil type, topography, stand height, stand height of the stand on the other side of the power line and wind exposition was estimated. The results showed a distinct edge effect. The edge of the forest had clearly lower damage frequency for all tree species. A marked difference was observed between tree species and damage frequency.

Riskerar tatuerare hörselnedsättning i arbetet?

Purpose: To examine the hearing environment for tattoo artists regarding occupational noiseand to see whether tattoo artists are exposed to hazardous noise according to Swedish WorkEnvironment Authority regulations. Method: Using a dosimeter we measured a total ofseven sessions of approximately one hour on seven different subjects, located on five studiosin Gothenburg. As a complement we did also hand out surveys based on twelve questions toexamine habits, experienced sound environment and to see if there were any hearing relatedpatterns. Results:. Sound level measurements showed that the lower exposure action valueLpAeq,8h 80 dB(A) in one case was reached if applied to the average working time of sixhours.

Möjligheter att förutsäga kvävegödslingsbehov i höstvete med Yara N-tester

The Yara N-Tester is a handheld chlorophyll meter which can be used in several different crops as an aid to determine if there is a need of complementary fertilization with nitrogen (N) or not. If the crop requires more N the N-Tester will recommend an amount in kg per ha. The possibility to assess the need of N depends on the strong relation that exists between chlorophyll- and N-concentration in the leaves of plants. In the multiannual trial series ?Nitrogen to winter wheat at different soil conditions? measurements with the N-Tester was carried out at flag leaf emergence (GS 37). In this work the result of measurements, the NTesters ability to estimate the need of N in winter wheat, will be presented for the years 2008-2011.

Akustik och säkerhet i inomhusarenor

The background to the study is that within the next ten years about 50 new multi-purposeindoor arenas will be built. These are used for various events such as sports, concerts, etc. In order to achieve a high level of security in the case of danger alarm signals and alarmmessages must be heard well by the visitors. ÅF-Ingemansson wanted to show builders the importance of good speech perception and that it is not observed in arenas today. They conducted technical tests on two large multi purpose indoor arenas to develop parameters that affect speech perception in the arena.To get a subjective view of how these arenas are experienced a survey was created.

Definition av stötdämpares fyllnadsgrad

Shock absorber units play a key role in establishing the driving dynamics and performance of automobiles. Öhlins Racing has manufactured high-tech automotive shock absorbers for over 30 years. Öhlins Racing?s advanced technology has contributed to over 200 world championships in automobile racing. Öhlin?s manufacturing process has long utilized automated fluid filling equipment during the final shock absorber unit assembly stage. The filling process consists of vacuum pumping the shock absorber unit and subsequent transfer of fluid. Vacuum pumping is necessary to remove residual air from the shock absorber unit prior to initiating the liquid filling stage. The presence of undesirable gases drastically compromises the performance of a shock absorber. The filling degree, defined as the final ratio of air to oil, is determined by the specific filling protocol as well as the specific equipment utilized.The current investigation aims to develop a viable technique to accurately determine residual air content in shock absorber units. If the filling degree can be appropriately quantified for a specific manufacturing process, then the air/oil ratio may be quantitatively related to shock absorber performance. The utilized measurement method must be completely integrated into the manufacturing process to guarantee shock absorber performance specifications according to the manufacturer?s standards. By utilizing the measurement method developed in this work, the manufacturing process, manufacturing equipment and product specifications can all be tailored to provide improved filling conditions.The developed measurement method provides accurate quantification of the filling degree under a wide range of processing conditions. The method establishes the relative quantity of air in the shock absorber unit by performing in-situ compressibility tests. The fill ratio can be controlled and varied by manipulating the vacuum pressure exerted during the filling process. Performance tests, however, indicate no correlation between filling degree and unit performance..

3D modelling of a Laser Welding Cell for movie presentation : making of the movie

This report describes a Bachelor thesis work in which a robotised laser welding cell has been modelled and simulated for the purpose of making a presentation movie. The report shows that the work has been concentrated on making the movie from the modelling phase through the recording of the movie and ending up with the editing of the final presentation movie. A pre-study was made prior the Bachelor thesis work. In the pre-study a literature study was conducted about measurement and calibration of a welding cell. Measurement of almost all equipment in the entire cell was also conducted in the pre-study.