Sök:

Sökresultat:

1271 Uppsatser om Waste of Electrical and Elektronic Equipment - Sida 14 av 85

Utredning av potentiella hälsorisker i samband med slagg- och slaggvattenhantering vid Hedenverket, Karlstad

In this study potential health risks for employees in connection with handling of bottom ash and bottom ash water at a Municipal Waste Incineration (MWI) plant have been investigated. Air surrounding the bottom ash and the bottom ash water has been examined. MWI is one of the primary ways to manage solid household waste, and bottom ash is the main solid residue produced by the incineration process. Bottom ash constitutes about 15-20% of the original waste. The bottom ash is extinguished in a water bath (bottom ash water).The study was carried out in a MWI plant in Karlstad, Sweden.

Design och implementation av konfigurationsverktyg för funktionsblock

Abstract In high voltage substations there is an increasing demand for computerized equipment, and automation of operation and supervision. The future primary equipment will provide the possibility to collect more information and to provide better control for improved effectiveness. Since ABB has got a large customer target, each product must be custom made to fulfil the customers (often from different countries) demands. Later these products will be configured by engineers who may not be familiar with the tools used at ABB. This is a very expensive and time consuming.

Kvalitetsprocesser och mätning av pinnfräsar : ? Empirisk studie av produktionsmätutrustning vid frästillverkning

This master thesis investigates quality procedures and measuring of solid carbide end mills, with the main focus on measuring equipment. The thesis has been written in collaboration with a special production department for solid carbide end mills at Sandvik Coromant in Gimo. The department?s needs and constraints have been the foundation of the project and the main research question is: how to measure end mills in order to ensure good quality of the produced end mills. The project has contained both a theoretical study consisting of a literature review and practical studies in the workshop with the objective to identify an end mill?s main parameters and the relationship between an end mill?s geometry and the manufacturing processes.

Skanskas säkerhet på arbetsplatsen : Personlig skyddsutrustning

This degree projekt deals with Skanska´s safety at the construction site with focus on personal safety equipment. The purpose of this dissertation is to examine how the rules of personal safety equipment are applied and experienced at Skanska´s construction sites.In October 2004 Skanska started a projekt to make the construction sites more safe. With use of a questionnaire we have made a survey at different construction sites. 80 questionaires have been handed out to Skanska´s employees in the southeast region. While they were handed out we conrolled if the employees at Skanska´s construction sites used head protection, easy visible clothing, safety shoes and identification cards.The result of the survey shows how the rules are applied.

Säkerhetsanalys av brandbekämpning i kritiska utrymmen på Forsmark 1

In order to maintain a high safety level at a nuclear power plant it is important not only to measure the reliability of the components and systems of the plant, but also to investigate how the plant responds to human actions. One of the most hazardous situations in managing a power plant is fire occurring in critical areas. This study concerns the prospect of the local fire brigade to suppress a fire that has started in one of the most critical rooms for maintaining high reactor safety. The model created gives an indication on the possibilities of succeeding in suppressing a fire. In order to get a more reliable fire fighting the following advice are given:- Let the fire brigade go rounds in the plant together with the personnel, during which recommended fire suppressing methods are determined to avoid long preparation time in an actual situation.- Prepare rooms with two subsystems to make them partly with no voltage.- Give the fire brigade better feedback from actual events on nuclear power plants.- Education and training in suppressing fires in electrical equipment.The probabilistic safety assessment strives to be as realistic as possible.

Vad påverkar fjärrvärmepriser i Sverige?: En ekonometrisk analys

The purpose with this thesis is to analyse different factors that can explain district heating prices for energy companies in Sweden. We are further interested in examining if the prices is affected by the use of industrial waste heat in their production and the company?s ownership structure. The method applied is a multiple regression analysis using a panel data set of 50 companies over 5 years (2008-2012). The data used is yearly data obtained from the Swedish district heating association.

GIS-program för ruttplanering. En studie av nyttjandet av GIS-program för ruttplanering inom tekniska förvaltningar bland kommunder i västra Sverige

This report is a study in voltagelevel in connection with regeneration of brake energy from the tramtype M31 in Gothenburg.In the act of braking, the tram M31 uses electrical braking where the electrical motors generates energy and if possible send it back to the overheadline, where other trams in the nearby can use this regenerated energy for its own driving force. In cases where no other energyconsumers are located in the same section, there is a resistance witch task is to convert this energy into heat. The regulation of this resistance appears to cause an increase in the voltagelevel into far too high levels.Investigations of the trams regulationequipment and its construction have been done. Further have measurements on the overheadline been performed in order to map the voltagevariations during a longer period of time.The result have been showing that the voltagelevel during regeneration often is as high as 880V-920V, more extreme values have not been observed in a large scale. The values are especially high compared to the nominal voltagelevel.

Peltierelement - spillvärme till el : Peltier element - waste heat into electricity

The purpose of this thesis has been to determine experimentally how good a peltierelement is to convert waste heat from wood burning. Three different peltier elementswere used in a comparison study. The comparison was mainly done to know howmuch power could be obtained from each element. Even, a circuit with a step-upfunction has been created to give a higher output voltage than the peltier elementitself. The result of the experiments was a low output power, the highest valuereached 2.18W.

Kaffesump som substrat i biogasanläggningar eller som bränsle i fjärrvärmeverk : en studie av effekter på växthusgasutsläpp och kostnader

Each year, the coffee machines at Ericsson in Kista produce around 100 tons of ground coffee waste.The companies Coor Service Management, Löfbergs Lila and Selecta are all responsible for differentstages in the logistical chain in delivering coffee and, together with Ericsson, they want to increasetheir environmental benefit. The plan is to produce biogas through anaerobic digestion instead ofincinerating the coffee waste in a heating plant. The results are to be presented as different businesscases in which different biogas plants are compared with the reference case (heating plant),comparing costs and environmental impacts.There are two major environmental benefits from producing biogas; reduced carbon dioxideemissions from when fossile fule is replaced by carbon neutral biogas, and reduced emissions fromreturning digestate from the bio reactor to farmland instead of using industrial fertelizer.In order to determine the biogas potential in coffee waste, a couple of properties had to bedetermined in a laboratory. Properties such as the dry substance content, heating value, moisturecontent and ash content. The results show that 100 tons coffee waste could produce around 16 500Nm3 biogas which would contain 163 MWh.The biogas reactor and upgrade plant both need energy gas to function and uses around 14 MWh ofthe produced gas.

Kvalitets och förbättringsarbete för ITtjänsteföretag

Wavecraft AB develops medical equipment for heating of organic synthesises. The heating is done with microwaves, which improves the process in both speed and accuracy compared to the more traditional methods where heating elements are used. This report discusses the developement of an automatic lid mechanism for one of Wavecraft's product prototypes. The company assumes that the final product will be integrated by customers into fully automated systems, and the upgrade from a manually to an automatically controlled lid is therefore an important step in the product's developement process.The first stage och the project was an idea generation process. The ideas generated here were organized into five different concepts of which the best one was selected through the use of a concept matrix.

Identifiering av synkronmaskinsmodell genom SSFR-test

At the Division of Electricity at Uppsala University there is an experimental rig forhydroelectric generators. The experimental rig?s vital part is a 12-pole synchronousmachine, whose electrical characterizing parameters (resistances, inductances andtime constants) are unknown. The aim of this thesis is to characterize the machine inits current state by perform a Standstill Frequency Response (SSFR) test. From theanalysis of the measurement data, which is a part of the test, a set of basic parametershave been received.

Kan perfluorerade ämnen i kläder bidra till förhöjda halter i reningsverk?

Perfluorinated substances (PF) are environmental pollutants that are used to coat fibres of so called ?all weather clothes? to make them water resistant. PF are effectively spread through water. Waste water treatment plants (WWTPs) are a pollutant source of these substances. PF are poisonous to different kinds of organisms, and supposedly also to human beings, if concentrations are sufficiently high.Perfluorinated substances have been investigated at three waste water treatment plants in Stockholm during the 2000?s.

Ombyggnation, från sågverkslokal till restaurang. antonio ziakoulis

Pharmaceuticals that are found in marine ecosystems are a threatening environmental concern, which is known to harm both animal and plant life. One of the reasons for this problem is that the waste water treatment techniques are not optimized to clear waste water from its pharmaceuticals contain. In this master thesis four Swedish treatment wetlands were studied, and their ability to reduce numerous pharmaceuticals in waste water. The four treatment wetlands that were studied were those in Oxelösund, Trosa, Nynäshamn and Eskilstuna. Two ecotoxicological tests and chemical analysis were used.

Restvärmeåteranvändning från absorptionsvärmepumpar : en kartläggning av möjligheter och begränsningar vid Vattenfall Värme Uppsala Block 5

Vattenfall district Heating power plant in Uppsala produces district cooling with absorption heat pumps which leads to a large amount of waste heat that has to be cooled with evaporative cooling towers. The Environmental Court has ordered Vattenfall to survey the possibilities to recover the heat, which is the focus of this thesis.The study begins with an overview of the system, and conditions and limitations for waste heat recovery is examined. In the next step alternatives to recycle the heat is evaluated, either by direct recovering or by upgrading.First, the technical possibility of each alternative is discussed, and then the operation time and the amount of recovered heat is calculated. Those alternatives which are possible are brought further to an economic analysis.The cost of investment for each alternative constitutes the basis for a present value analysis. The results are put together in a table where the total amount of recovered heat is compared with the present value for the different alternatives.

Radomoptimering för luftburna störsändarkapslar

These studies are done in behalf of Saab AB AVITRONICS in Järfälla in the form of a thesis atthe Royal Institute of Technology in Stockholm.The task was to examine the parameters that plays a role in the construction of modern radomesoperating in broadband applications.This was interesting for Saab to get an indication of which way they should go at the newdevelopment of radomes for the next generation of equipment for electronic warfare.After a thorough analysis of the influencing parameters, a optimization application was made toget a automated way to get a radome design by specifying data on the radome size, airloads,materials, etc.This is to minimise the time of the laborious work that radome development.inply.This was solved by letting ANSYS calculate the strength of the radome structure and MATLABcalculate electromagnetic data and cost models of different sizes and materials.All these parameters woven together with the optimization tool modeFrontier picks data from therespective program and perform an optimization algorithm and then iterate a step and sends thisdata to calculation programs for the new input data. In the end, we have received a convergedpoint with our optimal solution.For the presumptions and limitations for which applied for this thesis, the result was prettyintuitive. That is to say that the smaller radome - the less materal is needed and lowermanufacturing costs results in the cheapest solution possible. The reality is not so simple. Whereyou have to take more of the electrical details such as the effect on the transmitter as a majorfactor..

<- Föregående sida 14 Nästa sida ->