Sök:

Sökresultat:

228 Uppsatser om Steam pump - Sida 2 av 16

Solmodul jord- och bergvärmepump

An increasing number of heat pump producers have developed heat pumps that can be connected to solar panels. In this thesis we have examined the possibilities of connecting solar panels to existing ground source- and geothermal heat pumps that has not been adapted to solar panels. During the work process, a prototype plant has been built to compare our theory with the practical results and with our designed sizing tool. The work has rendered in knowledge that will be used to build a sun module that can be easily connect to the existing heat pump system. The existing heat pump, our test plant, has been supplemented by an advanced storage tank used to allow different operating modes.

Ljudreducering av värmepump

This degree project handles acoustic measurements of the heat pump EcoAir 107, made by Enertech CTC AB. The sound from the three sound sources of the heat pump, fan, compressor and four way valve, have been measured to find out how they affect the total sound level of the product.Measures to attenuate the sound level have been developed and tested. By comparing these with the sound of the heat pump, in its original state, we have found out the measures which have best effects.The best attenuating measures came to be: taped openings and holes around the compressor space, isolating the top and the bottom of the whole construction, support of the fan bottom part and shielding of the sound source with a screen at a distance of 110 mmThese measures have been tested together and an average attenuation of the total sound level with 3,9 dB have been accomplished. In the front of the fan where the continuous sound is the strongest, the attenuation was 4,7 dB.This project is meant to be used as a guide by Enertech CTC AB:s during their future developing process..

Energianalys av etanolproduktion : en fallstudie av Lantmännen Agroetanols produktionssystem i Norrköping

In this thesis an energy analysis of ethanol production at the ethanol plant of Lantmännen Agroetanol in Norrköping has been performed. The ethanol plant has been studied in combination with Händelöverket, the combined heat and power plant which provides the ethanol process with steam. The purpose of this study was to determine the energy consumption for the whole production chain from grain to ethanol. The analysis has included the energy consumption for cultivation of grain, production of chemicals, the production chain for wood chips, the steam production and the ethanol plant. The grain and wood chips are both considered raw materials there for the energy content in these are not included as energy input in the system.

Energianalys av etanolproduktion : en fallstudie av Lantmännen Agroetanols produktionssystem i Norrköping

In this thesis an energy analysis of ethanol production at the ethanol plant of Lantmännen Agroetanol in Norrköping has been performed. The ethanol plant has been studied in combination with Händelöverket, the combined heat and power plant which provides the ethanol process with steam. The purpose of this study was to determine the energy consumption for the whole production chain from grain to ethanol. The analysis has included the energy consumption for cultivation of grain, production of chemicals, the production chain for wood chips, the steam production and the ethanol plant. The grain and wood chips are both considered raw materials there for the energy content in these are not included as energy input in the system.

Studie av skyddsavstånd mellan bergvärmeanläggning och skyddsobjekt i ett vattenskyddsområde

During installation and operation of a geothermal heat pump system leakage of an antifreezing agent can appear in a borehole and leak out in surrounding groundwater. To guarantee high quality drinking water for generations to come Sweden has dedicated some areas as water protection areas. The local authority gives permits for the installation of heat pump systems within water protection areas. Before giving a permit the local authority makes an evaluation of the risks involved in installation and operation of the system within the area. By keeping a certain distance between the protected object in the area and the heat pump system the risk of polluting the protected object with an anti-freezing agent can be reduced.This thesis makes a comparison between three different methods of calculating an appropriate distance between the protected object and the heat pump system.

Leder patientinformation om PCA-pump till effektiv sma?rtlindring vid postoperativ va?rd - en kvantitativ studie

Bakgrund/syfte: Sma?rtlindring via PCA-pump a?r en effektiv och sa?ker metod vid postoperativ va?rd. Den syftar till att ge patienten sto?rre mo?jlighet att pa?verka sin sma?rtlindring. Tidigare studier pa?visar att ma?nga patienter upplever sin kunskap om PCA- pumpen som otillra?cklig.

Användning ac PCA-pump ur ett sjuksköterskeperspektiv

ANVÄNDNING AV PCA-PUMP UR ETT SJUKSKÖTERSKE-PERSPEKTIV EN ENKÄTSTUDIE BODIL ANDERSSON-FRANKE ANNA FRIDÉN-HANSSON Andersson-Franke, B & Fridén-Hansson, A. Användning av PCA-pump ur ett sjuksköterskeperspektiv. En enkätstudie. Examensarbete i omvårdnad 15 högsko-lepoäng. Malmö Högskola: Hälsa och Samhälle, Utbildningsområde omvårdnad, 2009. Syftet med denna studie, var att belysa sjuksköterskans erfarenheter och upplevel-ser av PCA-pumpsbehandling som en del i smärtlindringen inom postoperativ omvårdnad.

Luft/luftvärmepump : - Med möjlighet till återvinning

Sweden has long had access to low electricity prices due to the wide availability of hydro and nuclear power. This has now changed because of today's rising electricity rates resulting in increasing heating costs for properties, especially in the properties with electric heating systems."Ankaret" is a parish for "Svenska Alliansmissionen", which is located at "Gullbrannagården".The parish has installed electrical radiators and an exhaust ventilation system that makes the energy demand high due to the large ventilation flows. The building was built as the price of electricity was still low and would reduce energy use today by combining its heating system with an air/air heat pump. The heat pump delivers more heat into the room than the electrical energy that it uses. This lowers the electricity needs.

Konstruktionstudie av en ångexpander

This thesis applies to a novel steam expander, one part of a steam engine system, a wobble plateengine. The piston in the expander moves axially with the outgoing rotating shaft and is locatedon a plate, why the engine type is called axial engine. When steam is applied to the plungers theplate wobbles creating a rotation on the shaft going thru the wobble plate. The steam expander issupposed to be used in exhaust gas recovery (bottoming cycle) applications and small scaleenergy production. The commissioner is Ranotor Utveckling AB.

Jämförelse av frånluftsvärmepumpar

In order to reach the environmental targets, set up by the EU, there are many measures taken to make Sweden more energy efficient. In the housing and real estate sector, an installation of an exhaust air heat pump that reuses the heat in the exhaust air in order to lower the amount of acquired energy, is an example of such an action. The recovered energy can then be used for heating of radiators and tap water. This report aims to evaluate and compare three different systems using exhaust air heat pumps regarding COP, degree of coverage and cost savings. This study was delimited to only account for apartment buildings.The theory chapter describes the different conditions and factors that affect a building?s energy balance.

Projektering av ett småhus samt ekonomisk jämförelse av värmesystem

Design of a house requires knowledge of both technology and economics. Heating and ventilation shall be designed, costs are calculated and estimated and requirements must be fulfilled. Which heating system is to be elected is also a difficult choice, especially with rising energy prices as a factor.The choice of energy system is not always given, because it depends on several factors. Below is a comparison between district heating, geothermal heat pump and electric boiler from an economic standpoint. In a previous report appears district heating and geothermal heat pump as the best options.

Skalkonstruktion : Med inriktning mot hållfasthet och dämpning av ljud

The sound part is mainly practical and is dependent on concepts that have been tested through measuring with a sound level meter. The design part is more theoretical and has been verified with CAD models and finite element analysis.With a sound damping hood on the compressor the sound level is reduced with up to four dB. An optimized absorbent for the compressor space gives a reduction with three dB. By using the insulation for the heat water tank as absorbent we can see a sound reduction on the lover octave bands. A reduction like this is elsewhere hard to achieve as at it requires thick absorbents.By changing the today?s insulation to the heat water tank to a form of polystyrene polymer insulation the weight from the heat pump above can be transferred to the stable heat water tank.

Energieffektivisering på Skutskärs Bruk : Varvtalsstyrning till utvalda pumpenheter på Blekeri 4

In modern society in terms of economics and environmental impact, it is important to ensure that a company is as energy efficient as possible to reduce the amount of energy used. About 10 TWh of electricity used annually to pump drives in Swedish industry. Therefore, pumping system has great potential for energy savings.The objective of this report was to determine how much energy and money that can be saved with the insertion of variable speed drive to six pumps on Bleach plant 4 in Skutskär Mill. The work was performed with electrical measurements during one week, analysis of pump curves and the compilation of production data over a year.The results show that four of these six pumps were profitable and yielded an annual saving of 1172 MWh of electricity and 560 000 SEK. With an economic lifetime of 10 years and a discount rate of 6.8% the final result for the entire life-cycle savings became 3 355 000 SEK.

Underhållskoncept : tillståndsbaserat underhåll på smörj- och hydrauloljesystem

AbstractThis report describes our ten week long thesis work which is the last task in our education in mechanical engineering at Linköpings University. The project has been performed at Siemens Industrial Turbomachinery AB?s service department. The company which is located in Finspång produces, sells and provides service for steam and gas turbines around the world.The purpose of this project is to help Siemens develop their maintenance programs for two of the auxiliary systems which are a part of the complete steam turbine system. These are lube and control oil systems.The project is restricted to two of Siemens maintenance products, No Stop Check (NSC) and the annual Safety Inspection (SI).

Elproduktion med ORC-teknik ombord på fartygsserien MK II.

Given that the oil prices have risen and the environmental regulations has become more stringent, the interest in operating efficiency has increased. The project has investigated the possibility of producing electricity from waste heat generated in the diesel process. One technique to utilize and convert energy into electricity is the ORC (Organic Rankine Cycle). This process is based on the Rankine process (the steam process), the difference from the traditional Rankine process is that instead of water as a working medium, an organic substance is used. The main component used in the process is a evaporator, a turbine, a condenser and a pump.

<- Föregående sida 2 Nästa sida ->