311 Uppsatser om Solar cooling - Sida 10 av 21
Energikartläggning av avfallsförbränningen i Uppsala
Vattenfall Heat Uppsala runs the waste incineration plant in Uppsala, which produces district heating, process steam, district cooling and electricity. Vattenfall Heat Uppsala has decided to introduce an energy management system with the aim to increase the energy efficiency of the plant. The basis in such a system is to make an energy mapping.In this thesis an energy mapping has been performed at the waste incineration plant with the aim to identify and determine the size of energy flows. The investigated energy flows are used fuel, produced and used steam, produced district heating and cooling. Also the use of electricity to run the processes has been investigated.
Konceptstudie av solcellsdriven bil
World Solar Challenge är en tävling i Australien vars syfte är att främja utvecklingen av förnyelsebar energi. Här deltar olika universitet runt om i världen och för att bygga en solcellsdriven bil som drivs av solens energi. Den ska sedan köras en sträcka mellan Darwin och Adelaide på dryga 300 mil genom Australien på kortast möjligast tid.Projektet görs för Tekniska Högskolan i Jönköping till en kommande kurs som studenter kan söka sig till för att delta i World Solar Challenge 2013. I kursen ingår att bygga en solcellsbil som man sedan tävlar med.Genom att sätta upp krav som är nödvändiga och önskvärda i en funktionsanalys får projektet en utgångspunkt och ett stöd som bestämmer hur konceptet ska se ut och vilka krav som måste uppfyllas. De restriktioner som tävlingsledningen för World Solar Challenge upprättat kan omvandlas till nödvändiga krav i funktionsanalysen.Researchen, restriktionerna och de teorier som de aerodynamiska aspekterna pekat på bestämmer hur konceptet är utformat.Resultatet i projektet är en solcellsbil som med hjälp av sin sammanhängande form får goda aerodynamiska egenskaper och kan på det sättet konkurrera om en topplacering i World Solar Challenge.
Energismart modulhus med takintegrerade solceller
The purpose of this thesis is to examine how investments are justified in the Swedish data center industry, with a focus on cooling equipment. This is achieved through semi-structured interviews with 20 different interviewees. These interviewees represent different facets of the industry and facilitate an understanding of which factors, such as: investment costs, operating costs, reliability, environmental impact and the influence of external and internal actors, come into play and to which degree they impact the investment decision-making process. The results show that primarily low operating cost in the form of low energy consumption is the driving factor when it comes to the procurement of new equipment. A lower environmental impact is a positive side-effect of lower energy consumption.
Ett flervariabelt feldetekteringssystem för övervakning av bärlagertemperaturen i vattenkraftturbiner
The purpose of this thesis work was to develop an automatic fault detection system for surveillance of bearing temperature in hydropower turbines. The parameters used except the bearing temperature were cooling water temperature and cooling water flow. A simple static model based on data sampled every minute was developed to estimate the bearing temperature. Then a detector for detection of change in bearing temperature based on the CUSUM-algorithm was designed. Since the amount of data was very small the developed model was too uncertain to be used in a working system.The designed fault detection system showed to work well for the available data.
Kvalitetsbristkostnader hos Arctic Solar AB: kartläggning av
icke värdeskapande kostnader i förädlingsprocessen av
solceller
I ett samhälle där nyskapande teknik och goda kommunikationsmöjligheter gör marknader globala blir kvalitetsutveckling ett allt mer utbrett verktyg för företag att skapa sig konkurrensfördelar. Det har visat sig att stora summor pengar spenderas för att åtgärda fel och brister som uppstår på grund av bristande kvalitet. En nyligen genomförd opinionsmätning bland svenska företagsledare visar att dessa i genomsnitt bedömer dessa till närmare 25 procent av sina verksamheters omsättningar. Att kartlägga dessa så kallade kvalitetsbristkostnader kan således vara en guldgruva för verksamheter som kan förbättra sin lönsamhet utan att det sker på bekostnad av kvaliteten. Det här projektet har genomförts på Arctic Solar AB som i dagsläget har liten eller ingen kunskap över vilka kvalitetsbristkostnader som finns eller hur stor omfattning dessa har.
Marknadsundersökning inom datacenterbranschen : Undersökning av tekniska inköp, med fokuspå kyllösningar
The purpose of this thesis is to examine how investments are justified in the Swedish data center industry, with a focus on cooling equipment. This is achieved through semi-structured interviews with 20 different interviewees. These interviewees represent different facets of the industry and facilitate an understanding of which factors, such as: investment costs, operating costs, reliability, environmental impact and the influence of external and internal actors, come into play and to which degree they impact the investment decision-making process. The results show that primarily low operating cost in the form of low energy consumption is the driving factor when it comes to the procurement of new equipment. A lower environmental impact is a positive side-effect of lower energy consumption.
Restvärmeåteranvändning från absorptionsvärmepumpar : en kartläggning av möjligheter och begränsningar vid Vattenfall Värme Uppsala Block 5
Vattenfall district Heating power plant in Uppsala produces district cooling with absorption heat pumps which leads to a large amount of waste heat that has to be cooled with evaporative cooling towers. The Environmental Court has ordered Vattenfall to survey the possibilities to recover the heat, which is the focus of this thesis.The study begins with an overview of the system, and conditions and limitations for waste heat recovery is examined. In the next step alternatives to recycle the heat is evaluated, either by direct recovering or by upgrading.First, the technical possibility of each alternative is discussed, and then the operation time and the amount of recovered heat is calculated. Those alternatives which are possible are brought further to an economic analysis.The cost of investment for each alternative constitutes the basis for a present value analysis. The results are put together in a table where the total amount of recovered heat is compared with the present value for the different alternatives.
Energianvändning i restauranger i Umeå kommun
Efficient energy use in restaurantsUmeå Municipality wishes to combine energy issues with food control, and thus help restaurants to become more energy efficient. During March and April 2010, I visited seven restaurants and interviewed restaurant personnel about current state and application of kitchen appliances, using a checklist to make sure that the same questions were asked at all restaurants. The restaurants were all different sizes and offered different kinds of food. The study mostly focuses on energy efficiency by behaviour and not on location or technology. Almost every restaurant that was visited had the potential to improve in one or more areas, such as kitchen appliances, lamps and lighting fixtures, heating, cooling and ventilation.
Elektromagnetisk och mekanisk design av en 20MW turbogenerator
At the Division of Electricity at UppsalaUniversitythere are ongoing researches, including a research concerning turbo generators.Turbo generators produce a large share of electricity in the world; however they are costly mainly due to the fact that the cooling and ventilation that are needed to eliminate the excess heat from the generators are expensive. Turbo generators work with high efficiency and in this project, the main task is to simulate a generator while taking into account that the generator must be designed against self-oscillation, centrifugal force, exhaustion and heat. The turbo generator must be simulated without being too expensive and complicated.In this project, the dimensions of the turbo generator depend on the efficiency of it, and where the losses are in the generator. Furthermore, the optimum values need to be chosen with the help of the ACE simulation program. The report begins with an introduction describing the project followed by a task description that is dealing with the project.
Undersökning av förskolan Temmelburken certifierad enligt Miljöbyggnad : Termiskt klimat, energianvändning och höjning av certifieringsnivån
WSP building physics in Stockholm has certified the preschool Temmelburken in Bromma with the system of certification Miljöbyggnad. The rating of the building became BRONZE. In this thesis the preschool has been investigated with respect to the three areas: thermal climate, use of energy and improving of the level of certification. The thermal climate at the preschool has been investigated by a questionnaire survey and by measurements in order to do comparisons between the results from the two investigations as well as with the results of the simulations that WSP has done at the certification of the preschool. The differences between the results from the simulations and the questionnaire survey for winter as well as from the measurement performed with a comfort meter the 19th of March are concidered to be reasonably small since they give rise to the same rating according to Miljöbyggnad. Operational data for the use of energy for the preschool have been obtained in order to do comparisons with simulations performed by WSP and Svenska Besiktningar AB. The comparison shows that the simulated values for the specific use of energy are lower than what the real specific use of energy would be for the preschool, since just the operational data for the heat energy is higher than the simulated values. At the investigation of the possibility of improving the level of certification it was found that the rating of the preschool can be raised from BRONZE to SILVER by improving the ratings of the ?thermal climate summer? and the ?daylight?.
Energikartläggning och driftoptimering genom behovsstyrning i befintlig fastighet
Energy supply in Sweden year 2011 amounted to 577 TWh. The final energy consumption for industrial, residential and service was 379 TWh. Sweden has energy policy goals to reduce energy use in buildings. One of these goals is to reduce the energy use by 20 % in 2020 compared to the year 1995. An important step to achieve this goal is to target energy efficiency measures in existing buildings.
Underlag för solcellsproducerad el i Stockholm : Potential och klimatpåverkan
The City of Stockholm has decided to invest in renewable energy and especially in photovoltaics. The objective of this thesis is to investigate the photovoltaic potential on roof areas that the city possesses and to further investigate some buildings of the Property Management Department. The thesis also compares some existing photovoltaic plants with the solar irradiance map which shows available roof area on each building in Stockholm. The report ends with a literature study about the climate impact and greenhouse gas emissions of photovoltaic.The total available roof area suitable for photovoltaic plants is estimated to 700 000 m2, with a potential electricity production of 110 GWh per year. This corresponds to 17 % of the City of Stockholm?s yearly electricity consumption.
Analys av hur byggnadens höjd påverkar energiförbrukningen i flerbostads- och kontorshus
This diploma work has been carried out in collaboration with the building contractor Sh Bygg Fastighetsutveckling AB in Uppsala with the intention to investigate how the height of a building affects various energy aspects such as transmission losses, infiltration, and the specific energy usage. Three different reference objects have been studied. The reference objects have been simulated for four different heights in the calculation program VIP-Energy.The results show that an increase in floor number can lead to both advantages and disadvantages. As the number of floors increases, transmission losses per square meter floor area decreases. However, as the height of the building increases, the reduction rate decreases.
Morgondagens effektiva fjärrvärme : En beskrivande litteraturstudie
This report is made as a literature review, focusing on the work done to increase understanding of efficiency in the categories of substations and secondary heating systems, with respect to the deviation from the theoretically possible cooling off in the distribution network as well as the economic benefit that appear. The main purpose of a considerable part of the literature used in this report addresses the issue of identifying individual causes of reduced cooling in district heating systems. These literature resources have been compiled and summarized as part of the report.The technology of district heating is associated with benefits such as better use of the energy in a fuel. This is the case of cogeneration plants where serial generation of electricity and thermal energy increases efficiency compared with the parallel generation where heat is generated locally and electricity is generated centrally. Serial generation thus allows for lower primary energy demand.
Funktionsupphandling av solelanläggningar
This thesis aims to contribute to improved functional procurement of photovoltaic systems, PV systems. Functional procurement means that criteria concerning a function are set rather than specifying technical details or products. Possible advantages and difficulties in using functional procurement have been analyzed by interviews, simulations and a case study. Electricity production and surplus production for different scenarios have been simulated via MATLAB. The MATLAB script was also used to generate rules of thumb on feasible solar fraction for six different load profiles; a church, a farm, a car mechanic, an office, an industry and an apartment building.