Frånluftsvärmepumpens möjligheter i flerbostadshus
If a building is heated by a heat pump, it is of high importance that the heat pump has a high coefficient of performance. An exhaust air heat pump extracts heat from the building?s exhaust air. The air has a relatively high and constant temperature all year around, leading to a high seasonal coefficient of performance. This thesis examines whether it is profitable to complement an exhaust ventilation system with an exhaust air heat pump in an apartment block that already has geothermal heat pump, district heating, oil- or biofuel heated system.
Utfackningsvägg av lättbetongblock i passivhus
AbstractThis report intends through a case study to investigate if lightweight concrete isappropriate as main material in the outer wall of a seven storey residential building.A technical design is carried out in accordance with the definitions and requirementsfor passive houses, given by FEBY?s1 ?Demand specification for passive houses?.A literature review is also carried out for a comparison between regular bolt wall andlight weight concrete wall, with a focus on the safety of moisture.The lightweight concrete block used in the report is as a celblock produced by thecompany H+H Sweden AB.The methods used have resulted in compliance with requirements andrecommendations from authorities. Calculations of energy, noise and moisture riskassessment has been carried out.The work has resulted in the conclusion that the lightweight concrete itself is notable to isolate in the extent necessary to obtain chosen U-value of 0,1 W/m2 ° C,without getting to thick. Therefore additional insulation is needed. There are fewrelevant reference objects built with only light weight concrete.
Studium av stomsystem och övrigt klimatskal m.a.p. produktion och långsiktig förvaltning av passivhus
The passive house concept has been known for many years, but it is not yet verywell known in Sweden. The increased energy requirements places greaterdemands on our buildings and to meet these requirements, passive houses is agood option.Svenska Bostäder have built passive houses with good results and intend tocontinue design some of their new buildings as passive houses. This study ismeant to support Svenska Bostäder in their planning of new buildings byanalyze and compare the different frameworks and building shells of passivehouses.In the first chapters (1,2 and 3) we presents the conditions for passive housesand the differing objects we have examined more generally for the reader tobecome familiar with the concept and the objects.The subsequent chapter presents an analysis of each object partial based on thespecifications from FEBY and finally, in Chapter 5, you will find a table ofvalues where the objects are put into relation to each other and valued there by,together with a brief explanation for the table.This chapter also contains texts on the environment, design and futuredevelopment which all includes our own thoughts and reflections.Finally, the gist of the whole work and our conclusion is presented anddiscussed.On the whole, the work has been very enlightening for us and we hope that theconcept of passive houses have a wider impact in the future..
Upplevd trafiksäkerhet med mittbarriär
AbstractThis report intends through a case study to investigate if lightweight concrete isappropriate as main material in the outer wall of a seven storey residential building.A technical design is carried out in accordance with the definitions and requirementsfor passive houses, given by FEBY?s1 ?Demand specification for passive houses?.A literature review is also carried out for a comparison between regular bolt wall andlight weight concrete wall, with a focus on the safety of moisture.The lightweight concrete block used in the report is as a celblock produced by thecompany H+H Sweden AB.The methods used have resulted in compliance with requirements andrecommendations from authorities. Calculations of energy, noise and moisture riskassessment has been carried out.The work has resulted in the conclusion that the lightweight concrete itself is notable to isolate in the extent necessary to obtain chosen U-value of 0,1 W/m2 ° C,without getting to thick. Therefore additional insulation is needed. There are fewrelevant reference objects built with only light weight concrete.
Restvärmeåteranvändning från absorptionsvärmepumpar : en kartläggning av möjligheter och begränsningar vid Vattenfall Värme Uppsala Block 5
Vattenfall district Heating power plant in Uppsala produces district cooling with absorption heat pumps which leads to a large amount of waste heat that has to be cooled with evaporative cooling towers. The Environmental Court has ordered Vattenfall to survey the possibilities to recover the heat, which is the focus of this thesis.The study begins with an overview of the system, and conditions and limitations for waste heat recovery is examined. In the next step alternatives to recycle the heat is evaluated, either by direct recovering or by upgrading.First, the technical possibility of each alternative is discussed, and then the operation time and the amount of recovered heat is calculated. Those alternatives which are possible are brought further to an economic analysis.The cost of investment for each alternative constitutes the basis for a present value analysis. The results are put together in a table where the total amount of recovered heat is compared with the present value for the different alternatives.
Nollenergihus i Borlänge : Är det möjligt med biomassa, solenergi och vindkraft?
This report is of technical character and treats how to plan a small building in Borlänge, Sweden.The technical components that have been treated in the report are the construction, foundation,installations and thermic abilities of the house. In addition to planning this house the report alsocontains a part that deepens in net zero energy buildings. The purpose of the report is toinvestigate if the house in Borlänge can be constructed to meet net zero energy buildingdemands.Energy efficient houses such as passive- and net zero energy houses are showing more frequenton the market in Sweden. Ongoing climate changes and growing consciousness about theenvironment in society have contributed to that the environment is a well discussed topic. Toconsume small amounts of energy and at the same time produce local energy is thereforesomething that lies in the future and future houses.
Kartläggning av material flödesflaskhals i ICA butik.
In the spring of 2014 Sweco Systems AB were commissioned to design a ventilation system for a newly built preschool in Linköping. Terms from the client was that it cost efficiency would cope with the energy demands that are placed on the building. The unit chosen was a cross-flow heat exchanger, and this work is to compare it with two other heat exchangers to see if a more energy and cost efficient could have been chosen. The heat exchangers that was chosen for the comparison was a rotating- and a counterflow heat exchanger. Simulations have been made to the different heat exchangers by the manufacturers.
Datormodellering av en värmelagrande betongväggs inverkan på det termiska klimatet i ett växthus
This report describes the building of a computer model that makes it possible to simulate the thermal climate in a greenhouse. The computer model is built on the physical theory of heat exchange that occur in a greenhouse, such as radiation and convective heat exchange. The model also includes the heat storage that is active in a greenhouse.The computer model is used to simulate the thermal climate in a greenhouse under three periods, winter, spring and summer. It also investigates which effect a concrete wall has on the thermal climate in a greenhouse. The purpose of putting a concrete wall in the greenhouse model is to investigate the possibility to store heat during the day and then use this heat when the temperature drops during the night.The result from the simulations shows that a concrete wall levels the big difference in temperature that normally occurs under a day in a greenhouse.
Passivhus - lönsamt eller ej? : En jämförelse mellan ett passivhus och ett konventionellt hus
As a result of increased energy prices more and more energy-efficient homes are coveted. An energy-efficient alternative is passive houses, which is characterized by an extremely well insulated building envelope that recovers the heat without the use of radiators or under floor heating. But a passive house requires a higher investment cost than a conventional building project, since it will require more construction materials, training of construction workers, greater land area, and long construction period. But the lower operating cost expects to pay back the higher cost of investment. We therefore question how profitable a passive house is in relation to houses built according to modern conventional building techniques.The aim of our study is to investigate the viability of passive houses compared to conventional houses.
Värmepumpars inverkan på elkvaliten
Modern technology and fast development of heat pumps, the hunt for savings in energy consumption and the strive for environmentally friendly energy sources, convenience, and financial profit, have made heat pumps a reasonable alternative for the heating of houses.When the heat pump starts it will consume a considerable amount of current, which may result in a short-lived voltage-drop if the power grid is weak compared to the start-up current.The company Fortum Distribution which owns and administrates electrical network is interested in an investigation that deals with heat pumps affect on the quality of electricity.The purpose of this investigation is to study fast electrical fluctuations (flicker) as a result of start-up currents for single as well as multiple heat pumps on the same electrical station and from this evaluate whether there will be any problems installing heat pumps..
Värmestyrning I Handske
This rapport is result of a project. The purpose of which was to design a circuit that is used in a heat glove. The heat glove is the technical aid which provides heat inside a glove.It is specially suited for old people who have problems with cold hands because of decreased blood circulation.There already was an old circuit in the glove that gives a constant current which develops heat from battery to glove through a circuit. The temperature is between 32 and 34 degrees.The problem with the existing circuit was to regulate the temperature. There is only on/off switch and there is no way to adjust desirable value of the temperature.In order to solve the problem the old circuit was investigated.
Passiv face time - En studie av passiv face time på ett företag med flexibla arbetsförhållanden
The purpose of this study is to examine how employees in an organization using flexible work practices, experience that passive face time influences the evaluated of them. Further, the study aims to understand to what extent that perception of passive face time motivates the employees to spend more time at the office than is necessary for their work situations. The study concludes that employees in general perceive that passive face time does influence how they are evaluated and that this perception motivates employees that are relatively newly employed by the company to spend more time at office..
Inventering av värmelager för kraftvärmesystem
When a combined heat and power plant produces heat and power it often faces a deficit of heat load during the summer or other periods of time. This heat is often unnecessarily cooled away or the power production has to be reduced or shut off. If it is possible to store heat from periods with low heat demand to periods with high heat demand one can get many benefits. Among these benefits are: increased power production, decreased operation with partial load, uniformly distributed load.To be able to store heat in situations like this long-term thermal heat storages are needed. In this thesis five different types of stores are presented: rock cavern storage, tank storage, pit water storage, borehole storage and aquifer storage.
Värmeåtervinning på förskolan Rymdattacken 1 : En jämförelse av värmeväxlare
In the spring of 2014 Sweco Systems AB were commissioned to design a ventilation system for a newly built preschool in Linköping. Terms from the client was that it cost efficiency would cope with the energy demands that are placed on the building. The unit chosen was a cross-flow heat exchanger, and this work is to compare it with two other heat exchangers to see if a more energy and cost efficient could have been chosen. The heat exchangers that was chosen for the comparison was a rotating- and a counterflow heat exchanger. Simulations have been made to the different heat exchangers by the manufacturers.
Ett aktivt beslut att renovera passivt : En ekonomisk jämförelse vid upprustning av miljonprogrammetsflerbostadshus
As a result of increased energy prices more and more energy-efficient homes are coveted. An energy-efficient alternative is passive houses, which is characterized by an extremely well insulated building envelope that recovers the heat without the use of radiators or under floor heating. But a passive house requires a higher investment cost than a conventional building project, since it will require more construction materials, training of construction workers, greater land area, and long construction period. But the lower operating cost expects to pay back the higher cost of investment. We therefore question how profitable a passive house is in relation to houses built according to modern conventional building techniques.The aim of our study is to investigate the viability of passive houses compared to conventional houses.