Sökresultat:
809 Uppsatser om Passive heat - Sida 3 av 54
Samkörning mellan värmepumpar och fjärrvärme : Bostadsrättsföreningen Bogården
This diploma work covers an investigation over the heat - and hot water systems of thetenant-owner's association, Bogården. The heat - and hot water needs of Bogården aresatisfied by both district heating as well as three heat pumps. Implemented investigationshows that the heat pumps are not used in a profitable way. Apart from that, the reservepossibilities are small. There is also a risk of the growth of Legionella bacterium in thehot water system.Since the heat pumps are already installed, HSB-Gävleborg (responsible for Bogården)has a wish to investigate possible proposed actions for optimization of existing plant.After completed investigation, a new proposed action is presented.
Kompaktaggregat till Passivhus i Sverige
Kompaktaggregat är ett integrerat FTX- och FVP-system som används i passivhus. Vi har gjortenergiberäkningar i programmet VIP+ för att se hur kompaktaggregatet skulle kunna fungera ipassivhus i Sverige.De resultat vi har fått fram ur VIP+ visar att passivhus med ett installerat kompaktaggregat klararav att nå passivhuskraven ända upp till Skellefteå. De beräknade värdena understiger kraven förpassivhus, men en viss marginal behövs för att kraven ska nås även efter uppförandet avbyggnaden. Vi har även tolkat tekniska uppgifter på ett sätt som enligt oss har en positiv effektför passivhus på kallare orter. Därför tror vi inte att värdena för de tre nordligaste platserna ärhelt tillförlitliga.
Kompaktaggregat till Passivhus i Sverige
Kompaktaggregat är ett integrerat FTX- och FVP-system som används i passivhus. Vi har gjortenergiberäkningar i programmet VIP+ för att se hur kompaktaggregatet skulle kunna fungera ipassivhus i Sverige.De resultat vi har fått fram ur VIP+ visar att passivhus med ett installerat kompaktaggregat klararav att nå passivhuskraven ända upp till Skellefteå. De beräknade värdena understiger kraven förpassivhus, men en viss marginal behövs för att kraven ska nås även efter uppförandet avbyggnaden. Vi har även tolkat tekniska uppgifter på ett sätt som enligt oss har en positiv effektför passivhus på kallare orter. Därför tror vi inte att värdena för de tre nordligaste platserna ärhelt tillförlitliga.
Passiva lantbrukare ? en effekt av EU:s jordbrukspolitik : en studie av ett antal faktorers påverkan på svenska passiva lantbrukares attityder till markanvändning och EU:s jordbrukspolitik
The problem with passive farmers has arised as an effect of the European Union´s common agricultural policy (CAP) and the decouplement from production-based payments. Payments to passive farmers contradict the purpose of the single payment scheme and constitute a great cost for the EU. The new contractual period after 2013 has given rise to discussions on the direction of the CAP with a purpose of increasing the efficiency of the single payment scheme, and reducing passive farming. The aim of the study is to increase the knowledge about a few factors? influence on passive farmers? attitudes towards land use and the CAP.
Spillvärmeåtervinning ur kylvattensystemet ismältverket på Sapa Profiler AB i Sjunnen
The smelting process at Sapa Profiler AB in Sjunnen generates large quantities of waste heat which is absorbed by the cooling water when the aluminum is cooled down. This paper is the result of a Master?s Degree Project aiming to present the conditions for recycling the waste heat. The cooling water absorbs the heat from the aluminum at an average rate of 600 kW and the paper shows that it can be used to replace electrical power consumption for heating the production plant?s facilities.
Prefabricerade passivhusväggar
Background: The most energy efficient houses today are so called passive houses. These houses achieve high energy-efficiency partly by having well insulated walls. U-value describes the amount of heat transfered through a building element, the more insulation, the smaller U-value. A typical passive house wall have a U-value of 0.10 W/m2,°C. The passive houses are primarily made as small family houses and not as a block of apartments.
Heat Maps : En metod för att uvärdera banor
Denna rapport har undersökt om game metrics genom heat maps kan användas för att hitta en choke point i en bana gjord till spelet Team Fortress 2. Game metrics och kvantitativa metoder erbjuder ett objektivt och nästan automatiserat alternativ till kvalitativa metoder när det kommer till balansering. En bana har konstruerats med en choke point och har speltestats för att generera en heat map. För att undersöka om det går att hitta en choke point med hjälp av en heat map så har en enkät gjorts där respondenter bads hitta choke pointen med hjälp av den heat mapen som genererades från speltestningen av banan. Alla respondenter lyckades hitta mitten av choke pointen med hjälp av heat mapen. I framtiden skulle arbetet kunna utökas genom att undersöka om användandet av bottar eventuellt skulle helt kunna automatisera balanseringsprocessen. Det skulle också gå att undersöka hur olika klasser rör sig i en bana..
Solmodul jord- och bergvärmepump
An increasing number of heat pump producers have developed heat pumps that can be connected to solar panels. In this thesis we have examined the possibilities of connecting solar panels to existing ground source- and geothermal heat pumps that has not been adapted to solar panels. During the work process, a prototype plant has been built to compare our theory with the practical results and with our designed sizing tool. The work has rendered in knowledge that will be used to build a sun module that can be easily connect to the existing heat pump system. The existing heat pump, our test plant, has been supplemented by an advanced storage tank used to allow different operating modes.
Potential för värmeåtervinning från mjölkkylanläggningar
The present climate discussion has made energy efficiency an interesting topic. Saving energy does
not only help the climate but also saves money for the energy consumer.
The purpose of this thesis was to examine the potential of heat recovering from milk cooling. Two
milk farms, one with voluntary milking system, VMS, and the other with conventional milking system
was used to measure interesting temperatures and electricity consumptions. The numbers were used
both to do theoretical calculations and to construct a SIMULINK model.
To calculate the potential for heat at milk farms theoretical calculations were made in MATLAB using
a reference farm with different combinations of heat recovery and pre cooling. The farm was
assumed to keep a dwelling house with the annual heat consumption 18165 kWh.
Passivhus av helväggselement i träull
Environmental destruction is a growing problem in our world. Almost every day there are new reports concerning that we have to do something about the greenhouse gasses. Simultaneously is the human constantly more eager to have a life with higher standards and therefore uses more energy. The environment is a question that is highly up-to-date and more people try to find solutions on how to save our planet. One way to decrease the energy demand is to build passive houses, where the houses don?t have any active heating.
En kombinerad Organisk Rankinecykel och värmepump integrerat med ett fjärrvärmesystem : Där värme- och elproduktion samt lönsamhet studeras och avfall är huvudbränslet
The demand for district heating is expected to decrease in the future, due to competition from heat pumps and energy efficiency measures in buildings. Development of existing district heating systems is therefore necessary for district heating companies to maintain market shares. This Master?s thesis describes and investigates the heat and electricity production and profitability of a combined Organic Rankine Cycle (ORC) and heat pump that is integrated with an existing district heating system. The studied district heating system is utilizing heat from waste incineration. In Sweden waste constitute 20 % of the fuel mix used in district heating systems, and this share is expected to increase in the future.
Passivhus ? lönsamhet och komfort
In this essay, we have compared a conventional house to a passive house. The housesshared the same local conditions; they have the same living area and the same layout. Thedifferences between the houses were the different construction solutions for the roof, theouter walls, the floor and the heating system. Both the houses qualify the standards fromBBR and the passive house also lives up to FEBY?s special conditions.The purpose with the essay was to examine if it really is profitable to build small hoses aspassive houses.
Genetisk variation i brunststyrka hos svenska mjölkkor :
When cows in Sweden are inseminated the heat strength is reported to the Swedish milk-recording scheme and AI scheme. Cows that show strong signs of estrus are desirable and the trait is included in the Swedish breeding goal. A strong heat makes it easier to inseminate at the right time and to avoid long and expensive days open. Since ten years the heat strength is scored from one to five by the farmer and reported to the milk-recording scheme and AI scheme. Earlier the score was from one to three and the decision was made by the AI technician.
Passivhus, detaljutformning och dess köldbryggor
Along with rising energy prices and increasing awareness of environmental issues, the criteria for buildings energy performance have been sharpened through the years. Today, ?passive house? and ?low energy house? are commonly used phrases in the construction industry and is expected to become increasingly common in the future.For houses with well-insulated building envelope the importance of well constructed details increases when minimizing the heat losses. Examples of these details are floor-wall junction and window openings in the wall. In such connections thermal bridges occur, which means that heat more easily is transported out of the building, compared to the rest of the building envelope.This report deals with detail solutions around windows and a comparison between a traditional slab and a foundation from Koljern consisting of foam glass.
En studie av Uppsala stads värmeö
The urban heat island is an area restricted to a city center where the temperatureis higher than its surrounding environment. The greatest temperature difference isfound at night when the weather is calm and the sky is clear of clouds. There are twomajor causes behind this phenomena and the first one is the use of energy forheating of houses. The heat leaks through the walls of the buildings and warms upthe surrounding mass of air. The second one is the use of building material whichstore the suns radiation on daytime and releases the heat during night.