Sök:

Sökresultat:

165 Uppsatser om PCA-pump - Sida 2 av 11

Energieffektivisering på Skutskärs Bruk : Varvtalsstyrning till utvalda pumpenheter på Blekeri 4

In modern society in terms of economics and environmental impact, it is important to ensure that a company is as energy efficient as possible to reduce the amount of energy used. About 10 TWh of electricity used annually to pump drives in Swedish industry. Therefore, pumping system has great potential for energy savings.The objective of this report was to determine how much energy and money that can be saved with the insertion of variable speed drive to six pumps on Bleach plant 4 in Skutskär Mill. The work was performed with electrical measurements during one week, analysis of pump curves and the compilation of production data over a year.The results show that four of these six pumps were profitable and yielded an annual saving of 1172 MWh of electricity and 560 000 SEK. With an economic lifetime of 10 years and a discount rate of 6.8% the final result for the entire life-cycle savings became 3 355 000 SEK.

Utvärdering av ett större bergvärmesystem i en flerbostadsfastighet som har konverterats från fjärrvärme

This master thesis is an in-depth study of an existing heating system at a household cooperative in Uppsala that has been converted from district heating to a bedrock heat pump system. The study focuses on an economical system optimisation of the building?s complete heating system. The aim was to determine how well a heat pump system in large buildings actually work, find out possible ways to optimize the existing system and point out important system parameters for new heat pump installations in larger buildings.The project points out a possible energy cost reduction of 45 % without investment and further cost reductions with equipment investments. A reduction by 30 % is possible by improvements in the regulation system and 15 % is possible by maintaining the brine system.

Elektrisk matarpump för bränslesystem: En förstudie

För att transportera bränsle från tanken till motorn används på tunga fordon idag vanligen en mekanisk pump, driven av och placerad på motorn. Anledningen till att ha en direktdriven pump är främst att det anses som den mest robusta lösningen för den relativt enkla uppgiften som bränsletransport och liten tryckökning anses vara. För att klara av motorstart och driftsfall med höga bränsleflöden är dagens pump överdimensionerad för det behov som finns större delen av tiden.Önskvärt vore att kunna reglera bränslemängden kontinuerligt, för att minska pumparbetet i de punkter matarpumpen idag har överkapacitet. En elektrisk pump kan regleras att endast pumpa bränsle efter behov och erbjuder även andra fördelar, som t.ex. fri placering, möjlighet att använda en mindre pump och tilläggsfunktioner genom mjukvara, exempelvis priming och automatisk avluftning.Projektet har genomförts i form av en förstudie med konceptgenerering för placering av komponenter och provning av dagens system för kravspecifikation.

Analys av massapumps- och mixerarbete vid Metsä Board Sverige AB, Husums Fabriker : Energibesparingsåtgärder vid blekeri 4 & 5 med jämförelse mot ny utrustning

Husums plant has a selection of different pulp pumps at bleaching plant 4 and 5. The displacement- (HC-pump, Sund Defibrator PTD-60) and centrifugalpumps (MC-pump, MCA 42-200, MCP 30/20) are of interest in this report. The centrifugal pumps are controlled by throttle valves, which result in an energy loss. Chemical mixers are used to mix ClO2 into the pulp before proceeding into a holding tower where the bleaching process occurs.The energy demand of the different positions has been measured or calculated to be used in comparisons against new equipment. Quotations were requested and delivered from Valmet and Sulzer.

Effektmätning i pump

The interest for power and energy measurement has greatly raised with todays increasing electricity prices and enviromental awareness. In the search for energy efficient solutions, the measurements are more complex due to increasing of non linear components. Harmonics and non sinusoidal voltages put high demands on sampling and filtering. Meanwhile, the price must be controlled so the customer still will find it interesting to invest in smaller plants. ITT W&WW asks for a robust, heat resistant power meter with compact dimensions to allow mounting inside the casing of a pump.

Uppbyggnad och reglering av en pumpstation till ett injektionssystem

I was assigned to the thesis as part of a project GMA AB (Ground Machinery Applications AB) is running. The project aims to develop a new method for injection of drilled holes in rock walls. Currently, the injections usually involve cement but the basic idea of the project is to replace cement with a supplement called Silica sol.Silica sol is known as a gelling liquid. The gel time is controlled by a mixing of saline. Depending on the amount saline that gets mixed in, the gel time varies.

Utvärdering av ett värmepumpsystems prestanda till en HWC-tvättmaskin : Med fokus på fläktvarvtal och köldmedieflöde

This report was performed in order to evaluate a new technological measure and focuses generally on a heat pump system to a HWC-washing machine. The client is Asko Appliances AB, a company well known for its environmentally friendly products. The goal of this study was to improve the energy efficiency of a washing machine by combining a heat pump device to the heater of the wash water, in order to reduce the energy consumed for heating the water. Besides reducing the energy consumption in heating the water, the washing machine was required to meet low noise and short operating time specifications. For that purpose, nine trials in three test series have been carried out.

Postoperativ smärtlindring efter hysterektomi: en jämförande studie

Syftet med denna studie var att jämföra två olika smärtbehandlingsmetoder för patienter som genomgår hysterektomi. Försöksgruppen erhöll både PCA pump ( patient ?kontrollerad-analgesi) och sårkatetrar och kontrollgruppen erhöll endast PCA pump. En PCA pump är en förinställd smärtpump där patienten själv sköter sin administrering av smärtlindrade läkemedel. En randomiserad studie utfördes där försöksgruppen bestod av 19 patienter och kontrollgruppen bestod av 20 patienter.

Hållbara uppvärmningsalternativ för hotellstugorna på Grinda : En kvantitativ studie gällande hållbara uppvärmningsalternativ på en skärgårdsö

Skärgårdsstiftelsen, which is responsible for several of the archipelago islands in Stockholm, has chosen to explore the possibilities for more sustainable heating systems in buildings on the islands in collaboration with KTH. A reduction of energy use and improving the efficiency of existing heating systems are included as part of the environmental work. This report studies the island of Grinda, which is located outside the area of Vaxholm in Stockholm. The study area consists of a guesthouse consisting of a restaurant as well as conference facilities and four neighboring cottages used for overnighting. The cottages now run solely on direct electricity, both for heating and hot water.

Konstruktion av balanseringsutrustning

Syftet med arbetet är konstruera en balanseringsutrustning för pump- och fläkthjul åt Billerud Karlsborg. Det finns en balanseringsutrustning på företaget idag, men den klarar inte av alla dimensioner på pump/fläkthjulen varför en bättre lösning vore önskvärd. Målet med det här projektet är att kunna presentera en lösning på en balanserings utrustning i form av ritningar på själva stålkonstruktionen samt ett förslag på hur drivning av utrustningen skall ske. Därmed skall projektet tillhandahålla Billerud med tillräcklig information för att en ny balanseringsutrustning skall kunna tillverkas. Utrustningen bör klara av att balansera rotorer med en vikt på upp till 250kg och en största diameter på 1500mm.

Lagring av kyla med horisontella markvärmeväxlare för kylning av koncepthus i Mellanöstern

Norconsult AB has developed a solarhousing concept, a house designed for the warm climate in the Middle East andwith large quantities of solar panels installed. The cooling system for the house was designed in an earlier report, the purpose of this thesis is to investigate the possibility of short and long term storage of thermal energy via an underground energy storage volume.Two different designs of the storage and three different filling materials have been integrated into a model to simulate different cases. The first design consisted of pipes installed in the ground, without insulation. The second design consisted of an insulated concrete box installed to prevent thermal energy from the surrounding soil to flow towards the lower temperature regions within the storage. The three different filling materials were dry saudi sand, water saturated saudi sand and the filling material used by the client for energy storage in Sweden.The results from the simulations show that neither of the designs, regardless of the filling material, managed to extract enough thermal energy from the house to the ground to uphold the demands of indoor climate.

En retrospektiv studie av vilka patientgrupper som erhåller insulinpump

MålsättningAtt utreda skillnader i tillgänglighet till insulinpump mellan olika patientgrupper samt vad som orsakar ett byte till insulinpump.MetodData från 7224 individer med typ 1 diabetes vid tio olika vårdenheter analyserades för att utreda effekterna av njurfunktion, kön, långtidsblodsocker, insulindos, diabetesduration samt ålder. Jämförelsen mellan patientgrupper utfördes med logistisk regression som en tvärsnittsstudie och Cox-regression för att utreda vad som föregått ett byte till pump.ResultatGenom logistisk regression erhölls en bild av hur skillnader mellan patienter som använder insulinpump och patienter som inte gör det ser ut i dagsläget. Cox-regressionen tar med ett tidsperspektiv och ger på så sätt svar på vad som föregått ett byte till insulinpump. Dessa analyser gav liknande resultat gällande variabler konstanta över tiden. Kvinnor använder pump i större utsträckning än män och andelen pumpanvändare skiljer sig åt vid olika vårdenheter.

Värmeöverföring i bergvärmesystem : En numerisk analys av den ringformade koaxiala borrhålsvärmeväxlaren

The borehole heat exchangers of today suffer from poor thermal and hydrodynamic performance. The purpose of this thesis is to improve the performance of ground source heat pump systems and thermal energy storages by increasing the energy efficiency of the borehole heat exchangers. For this reason, the annular coaxial borehole heat exchanger (CBHE) has been analyzed. This type of heat exchanger is interesting in terms of both thermal and hydrodynamic performance. A model has been set up in the program Comsol Multiphysics in order to investigate the heat transfer characteristics along the borehole.

Beräkningsalgoritm för fouling i pelletervärmeväxlare inom plasttillverkning

Sweden?s energy consumption is divided into three major sectors. One of them is the industry sector. One third of Sweden?s energy consumption is converted in the industries.

Fällning av kisel från avloppsvatten vid Hellisheidarvirkjun - experimentell studie

This report is about the experiments with mixing of the separated water and the vacuum pump seal water at Hellisheiði power plant. This is done to prevent silica scaling and clogging in pipes and reinjection wells as well as eliminating vacuum pump seal water from the plant. The experiments were done in four stages: the first stage comprised of tests with different flows of separated water at 70°C, the second stage was carried out by mixing the separated water at 70°C and the seal water with different amounts of the seal water, the third and the fourth stages were like the first and second but with the separated water at 120°C. The results show that this method is good if the mixture is around 50/50 separated water and seal water, to control the silica scaling in the separated water and to be able to reinject the seal water with the separated water. This does not eliminate the silica scaling in all of the separated water because the amount of separated water is much more than the amount of seal water that comes from the plant. .

<- Föregående sida 2 Nästa sida ->