1120 Uppsatser om Mid-phase Measurement - Sida 6 av 75

Omega System Kalibrering: Strål X-Separation mätning och kalibrering

Micronic Laser Systems AB produces and develops machines for the photo mask production market. One of their products is the Omega machine which exposes photo masks using 5 laser beams simultaneously. It is important that the distance between the each laser beam, the x-separation, is the same. The x-separation is today measured by exposing a photo mask with a certain pattern and thereafter measured with a metrology system. This takes to much time and it is desired to find a faster method to measure the x-separation without loosing precision.The task for this master thesis is to improve an existing measurement method which uses a calibration mask.

MILJÖCERTIFIERINGSSYSTEMET MILJÖBYGGNAD I PRODUKTIONEN : En fördjupning inom området ?Material?

The environmental assessment system Miljöbyggnad is a Swedish system initiated by Bygga-Bo-Dialogen to assess buildings with regards to three main areas; ?Energy?, ?Indoor climate? and ?Materials?. A building can obtain three different classifications depending on how well it manages to meet the demands. GOLD is the highest classification and is followed by SILVER and BRONZE. The majority of the measures needed to comply with the demands are done during the design phase.

Luftutsläpp från järnmalmsproduktion : - Strategier för systematisk luftkvalitetsmätning

The mining company LKAB extracts iron ore in three areas in the north of Sweden, Kiruna, Malmberget and Svappavaara. The iron ore is refined and in the pelletizing plants the material is rolled to finished pellet product. The different steps of pelletizing plants causes among other things emissions to the air. It occurs occasionally stops in the production and the emissions are vented via an emergency chimney without purification. The aim for this work is to look into how LKAB may improve their monitoring of air emissions and control of ambient air quality and the analysis methods which are suitable for measuring.

Projekteffektivitet inom tekniska utvecklingsprojekt : Vilka faktorer påverkar projekteffektivitet och hur kan dessa mätas?

The purpose of this thesis is to identify the factors that drive efficiency and effectiveness in technical development projects performed at A?F?s department of product development. In addition to identifying and analyzing these factors, the thesis also analyzes what needs to be taken in to account in order to implement a measurement system that is able to both monitor and control the identified factors.The thesis has been performed in a qualitative manner. It is based on interviews with people from several different technological companies, within different lines of business, all of which are customers to A?F?s department of product development.The results show that there are seven critical factors for project efficiency and effectiveness.

Pre-internationalisering : En fallstudie om beslutsfattare i små och medelstora företag och drivkrafterna mot en internationalisering

AbstractThis study is about describing the pre- internationalization phase and to studycompanies that are in this phase. We are trying to capture characteristics of decisionmakersin the pre- internationalization phase, to then compare the theoretical materialwith empirical material from case companies. Then in the final stages of the thesis, wewant to account for if we managed to answer our research questions. In the method, wegive a description of the approach selected in conjunction with the study. The study isqualitative and we used both primary and secondary data, with a deductive approach.The theory chapter will consider the most relevant theories that are related to the topic,which is internationalization, pre-internationalization, international entrepreneurship,and the psychology behind personalities, attitudes, and how these can affect theorganization's strategic decisions.

Harmonisering av redovisningsstandarder

Earlier models that measured de facto harmonization of international accounting mainly used indices and other related statistical models. Those approaches do not account for the relative importance of individual balance sheet items or expense items being harmonized. This paper therefore proposes a different approach using Runsten?s (1998) permanent measurement bias model. That way it is possible to quantify the harmonization process by accounting for differences among companies.

Nya metoder för vibrationsmätning på vindkraftverk

This project has revolved around finding better ways of overseeing vibrations of the gearbox at a wind power station. The gearbox has been a huge problem at the stations located at Gässlingen and the sooner the warning of an incoming breakdown is at hand the more money you can save from preparations. The work has been carried out together with Askalon AB in cooperation with consults from ÅF. Askalon is a company with a department focused on overseeing vibrations and it is in collaboration with that department the work has been carried out. During this work, new positions for the sensors and new methods of gathering and analyzing data have been worked out. This was then implemented at a wind power station to be tried out on site.

En studie av sex ISA-system

On a request from the water sewage plant Gryaab in Gothenburg a power quality survey was performed. The voltages and currents have continuously been sampled in the incoming 10 kV substation HSP01 from April-August 2008. Power quality measurements were also performed in Gryaabs other 10 kV substation HSP04 fed from HSP01 and at the terminals of the induction motor IN_PU4040 of 1.3 MW which controls one of the four large inflow pumps to the plant. The reason for the latter measurement was due to registered negative transients each time the motor was connected to the grid. The cause of the transients could be explained by the coupling in the substation, the ageing of the motor which could result in damage of the bearings or resonance in the motor circuit which amplifies high frequency harmonics.

Dynamisk simulering av avfallskraftvärmeverk

On a request from the water sewage plant Gryaab in Gothenburg a power quality survey was performed. The voltages and currents have continuously been sampled in the incoming 10 kV substation HSP01 from April-August 2008. Power quality measurements were also performed in Gryaabs other 10 kV substation HSP04 fed from HSP01 and at the terminals of the induction motor IN_PU4040 of 1.3 MW which controls one of the four large inflow pumps to the plant. The reason for the latter measurement was due to registered negative transients each time the motor was connected to the grid. The cause of the transients could be explained by the coupling in the substation, the ageing of the motor which could result in damage of the bearings or resonance in the motor circuit which amplifies high frequency harmonics.

Voltage Sags Indices and Statistics

Voltage sag indices are a way of quantifying the performance of the power supply, as far as voltage sags are concerned. Indices can be defined for individual events, for individual sites, and for a whole system. A standard method for single-event methods is part of IEC standard 61000-4-30.This thesis emphasizes the importance of voltage sag indices and different methods for calculating three-phase voltage sag characteristics. Three-phase events measured in a medium network voltage over period of one month were analyzed, results examined and statistically evaluated. An algorithm for calculating voltage sag characteristics and indices was created in Matlab.

Prognostisering av höga grundvattennivåer med Chalmersmodellen

On a request from the water sewage plant Gryaab in Gothenburg a power quality survey was performed. The voltages and currents have continuously been sampled in the incoming 10 kV substation HSP01 from April-August 2008. Power quality measurements were also performed in Gryaabs other 10 kV substation HSP04 fed from HSP01 and at the terminals of the induction motor IN_PU4040 of 1.3 MW which controls one of the four large inflow pumps to the plant. The reason for the latter measurement was due to registered negative transients each time the motor was connected to the grid. The cause of the transients could be explained by the coupling in the substation, the ageing of the motor which could result in damage of the bearings or resonance in the motor circuit which amplifies high frequency harmonics.

Rationell plattläggning. Studie av ett arbetsmoment

On a request from the water sewage plant Gryaab in Gothenburg a power quality survey was performed. The voltages and currents have continuously been sampled in the incoming 10 kV substation HSP01 from April-August 2008. Power quality measurements were also performed in Gryaabs other 10 kV substation HSP04 fed from HSP01 and at the terminals of the induction motor IN_PU4040 of 1.3 MW which controls one of the four large inflow pumps to the plant. The reason for the latter measurement was due to registered negative transients each time the motor was connected to the grid. The cause of the transients could be explained by the coupling in the substation, the ageing of the motor which could result in damage of the bearings or resonance in the motor circuit which amplifies high frequency harmonics.

Kvalitetssäkring av efterinjektering. En fältstudie i Nygårdstunneln

On a request from the water sewage plant Gryaab in Gothenburg a power quality survey was performed. The voltages and currents have continuously been sampled in the incoming 10 kV substation HSP01 from April-August 2008. Power quality measurements were also performed in Gryaabs other 10 kV substation HSP04 fed from HSP01 and at the terminals of the induction motor IN_PU4040 of 1.3 MW which controls one of the four large inflow pumps to the plant. The reason for the latter measurement was due to registered negative transients each time the motor was connected to the grid. The cause of the transients could be explained by the coupling in the substation, the ageing of the motor which could result in damage of the bearings or resonance in the motor circuit which amplifies high frequency harmonics.

Energianalys av Vikan Kross och Asfalt

On a request from the water sewage plant Gryaab in Gothenburg a power quality survey was performed. The voltages and currents have continuously been sampled in the incoming 10 kV substation HSP01 from April-August 2008. Power quality measurements were also performed in Gryaabs other 10 kV substation HSP04 fed from HSP01 and at the terminals of the induction motor IN_PU4040 of 1.3 MW which controls one of the four large inflow pumps to the plant. The reason for the latter measurement was due to registered negative transients each time the motor was connected to the grid. The cause of the transients could be explained by the coupling in the substation, the ageing of the motor which could result in damage of the bearings or resonance in the motor circuit which amplifies high frequency harmonics.

Metoder för kartläggning och analys av nätförluster i lågspänningsnät

An important process for grid companies in order to reduce power losses in electricity distribution grids is to figure out where and how they appear. This report describes the factors that cause power losses in low voltage distribution grids and methods for how they could be measured and analyzed. Measurement data for consumed and injected energy were collected for twelve low voltage distribution grids owned by Gävle Energi AB in order to analyze the size of the power losses and how the measurement uncertainty affects the collected data. Then models of three of the grids were created in MATLAB in order to analyze the data and the power losses were calculated to be compared to the collected data. Curve fitting were also used as a method in order to analyze the power losses from collected data.The results show that the losses in the studied grids are low.