Sök:

Sökresultat:

903 Uppsatser om Additional moisture - Sida 2 av 61

Fuktsäkert byggande : Sjönära bostäder i Östra Hamnen i Västerås

Housing construction very close to the lake Mälaren has become very popular today. One potential problem with these houses is the influence of the sea climate. Unprotected buildings are affected by strong winds and precipitation. So for that reason, it is very important to make an accurate climate investigation and use it for decision-making during the planning of the new settlement.It is very important with a good moisture protection regarding pelting rain, that is the combination of wind and rain. This is more important for buildings close to a lake, as this location normally means a higher exposure to wind.

Fuktegenskaper hos Quartzene impregnerat med salter

Svenska Aerogel AB has developed the material Quartzene® which is of the typeprecipitated silica and contains calcium - magnesium silicate ((Ca, Mg) SiO3). Thematerial is used for molecular filtration of contaminated air. Qartzene?, which is inpellet form, is porous and has a high internal surface which is a requirement for themolecular filtration. With the use of various impregnations, filtration can affect thedesired outcome.

Effektiv lagerstyrning genom tillförlitlig prognostisering : Effective inventory control through reliable forecasting

This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.The background of the problem with moisture is that today?s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate.

Tätning eller ventilering mot fukt på kalla vindsutrymmen

This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.The background of the problem with moisture is that today?s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate.

LÖNSAMHETSKALKYL AV FUKTSÄKERHETSANSVARIG VID RENOVERING : En fallstudie av ett projekt där ByggaF-metoden har använts

The so called ?ByggaF-method? is a relatively new Swedish method to stop moisture from being built into a building. The method should prevent damages on buildings as a result of mould growth and moisture. The purpose of the method is to include moisture control in the entire constructionprocess, from the projecting phase and all the way to the management phase. Up until now, there is no proof if the method is profitable or not and no studies have been made on the topic.

EAS-tagg med fuktsensor : Design och utvärdering av EAS-alarmteknologi för fuktdetektering

Electronic article surveillance (EAS) is widely used in shops and libraries together with an RF-tag attached to the goods or books in order to prevent shoplifting. By implementing the addition of a moisture sensor to the RF-tag, other functions become possible, including the ability to use as an alarm with regards to frozen goods, which have been shipped but which have melted and have, subsequently, refrozen. In- relation to care for the elderly, one time-consuming step involves checking whether there is the necessity for a change of diaper and this can, instead, be based on an RF-tag with an EAS-system alarm. A preliminary investigation was made using the moisture sensors, which involved how the resistance changes when liquid and/or heat is applied. A simulation of the LCCR circuit (RF-tag with the sensor) was conducted in order to determine how the resonance frequency changes for different resistances levels.

Droppbevattningens inverkan på kvalitet och kvantitet hos Solanum tuberosum L i jämförelse med konventionell spridarebevattning :

A literature study and a field trial have been carried out in order to investigate the physiological response of potato plants to different soil moisture levels. Higher yield, quality and number of tubers can according to the literature be obtained if constant high soil moisture is kept during major parts of the growing season. A field trial was set up where drip irrigation was used as an alternative to conventional irrigation techniques to maintain high and constant soil moisture. The application of water in the drip irrigated area was monitored and adjusted on a daily basis so that the soil moisture stayed as close as possible to the recommended level. The sprinkle irrigated area was irrigated according to traditional practices with approximately 35 mm every 7th to 10th day depending on the whether.

Elementkoncentrationer i gran utmed en markfuktighetsgradient :

One key factor in silviculture today is sustainability. In order to achieve sustainability it may be important to restore lost nutrients to the forest after clearcutting. In order to calculate the removal, you need to know how much of different elements you will find in different tree compartments. The aim of this study was to investigate if the concentration of elements in different tree compartments of spruce (Picea abies (L.) Karst) were related to the moisture conditions of the site. Five plots at Risfallet (60º 21´ N, 16º 13´ E), was placed along a moisture gradient in a 40- year spruce stand.

Automatisering av spraytorkningsprocess

ABB Surge Arrestors in Ludvika have for a long time had a problem to keep the moisture at a steady state in the production of their ZnO-powder, that is used to produce varistors.Some black-box models of the spray drying process have been designed and evaluated to find a solution for the problem. After evaluating the collected data it has been found that variations in the supply voltage causes control difficulties for the operator. A cascade control system was designed, consisting of three PI control loops designed with lambda tuning. The disturbance in the supply voltagewas used as a feed forward in the control system.At the end of the project the control system was installed, and tests were made to verify the functionality of the regulator. It was shown that most of the variations in the moisture of the powder could be eliminated using small resources, through purchase of a process controller and four power meters.

Tilla?ggsisolering och fuktproblem i grundkonstruktionen platta pa? mark : En fallstudie i flerbostadshus inom stadsdelen Sa?tra i Ga?vle

Between 1965 and 1974, the Swedish Parliament decided to build one million dwellings, called Million Program. The million program buildings were erected with new, untried design solutions, in a short range of time, and at low cost. The residential buildings from that time are now greatly in need of renovation. The municipal housing company, Gavlega?rdarna, renovates and improves the energy efficiency at some of it?s apartment buildings in the district Sa?tra, Ga?vle.

Mätning av träddelar och flis på Dåvamyran, Umeå energi :

The moisture content in 10 deliveries of tree parts and 10 deliveries of wood residues were measured with different methods to analyze the quality of procedure used at Dåvamyran today. At the same time a survey was made on the measure procedures used at heating plants in Sweden The majority of the heating plants in Sweden use weight and moisture content as base for payment but at some plants only volume. The moisture content is usually estimated by drying wood chips in an oven but few plants a visual estimation is used. At few plants moisture content is estimated spectroscopicily. The techniques using near infra read light and other electromagnetic are still at a test stage. The methods of measurement used today are quit unreliable for the individual deliveries and there is a risk for systematic mistakes.

En kvalitetskontroll - Snustillverkaren Fiedler & Lundgren kvalitetstestas

This paper aims to describe the variation and develop a method to control the production for the product Metropol Kaktus from the snuff developer Fiedler & Lundgren. We are going to use the requirements from the product specifications as limits of the expected quality when we present methods to control the process. One method attempts to control during the process and the other attempts to maximize the number of products with strived quality before the process starts. Metropol Kaktus is a product produced with high quality, the mean weight is 20,023 gram and this is very close to the weight, 20 gram, which is reported in the product specifications. The variation in weight variable is less than what is reported in the specifications and the minimum weight is over the limit set by Livsmedelsverket.

Utfackningsvägg av lättbetongblock i passivhus

AbstractThis report intends through a case study to investigate if lightweight concrete isappropriate as main material in the outer wall of a seven storey residential building.A technical design is carried out in accordance with the definitions and requirementsfor passive houses, given by FEBY?s1 ?Demand specification for passive houses?.A literature review is also carried out for a comparison between regular bolt wall andlight weight concrete wall, with a focus on the safety of moisture.The lightweight concrete block used in the report is as a celblock produced by thecompany H+H Sweden AB.The methods used have resulted in compliance with requirements andrecommendations from authorities. Calculations of energy, noise and moisture riskassessment has been carried out.The work has resulted in the conclusion that the lightweight concrete itself is notable to isolate in the extent necessary to obtain chosen U-value of 0,1 W/m2 ° C,without getting to thick. Therefore additional insulation is needed. There are fewrelevant reference objects built with only light weight concrete.

Vattenhaltmätning i konfektyr och sylt med Karl Fishermetoden

Abstract (in English)The task for the diploma work was to develop methods for measuring of moisture content by the Karl Fischer method, in jam, jelly sweets, and fudge.The start premises was a for the company whole new equipment, which should be started up. Then programs should be developed for different kind of samples.In the task it was as well included to develop methods for dissolving the different kind of samples, since the Karl Fischer method demands completely dissolved sample material..

Kartläggning av spånprodukter vid Sävar såg

A change towards using more biofuels than fossil fuels is taking place in Sweden, and in many other parts of the world. This makes the use of fuel pellets increasingly popular, causing a greater demand for sawmill sawdust products. There is a trend towards the use of multiple types of shredders, instead of a single type in each sawmill. The purpose of the study was to characterize the different flows of saw particles that can be found at Sävar såg when cutting thick or thin wood with different cutting techniques. The saw particles size, shape, moisture content and heat value were analysed by the cutting stations: first cutting fast and slow, second cutting fast and slow, grading fast and slow and planning.

<- Föregående sida 2 Nästa sida ->