Energieffektivisering av luftningssteget på Käppalaverket, Lidingö


This master thesis in energy optimization was made during the autumn of 2006 at Käppala wastewater treatment plant in Lidingö, Stockholm. A preceding thesis, where all electricity consumption was mapped, showed that the aeration in the biological treatment is the single largest consumer in the plant, and it is therefore of interest to reduce this cost. The oxygen control strategy used at Käppala WWTP is working well from a nutrient removal point of view, but not from an economic one. The last aerobic zones have a very low oxygen consumption during low loading periods which give rise to enhanced dissolved oxygen concentrations with excessive costs and reduced denitrification as a result. But also during periods of normal loading unnecessary high oxygen concentration are sometimes given.By modifying the aeration control strategy three full-scale experiments have been made, with the intention to reduce the air consumption. The experiments were carried out during week 37-50 in the autumn of 2006 and showed that savings could be made.The regular oxygen control at Käppala WWTP controls the oxygen level in the aerobic compartment with two DO-setpoints; one in the first aerobic zone and one in the last. The zones in between are controlled by an airflow fractionation depending on the oxygen level in the first and last zone. In the first strategy to be evaluated, all four zones in the aerated part were individually controlled with its own setpoint. Two different setpoint combinations were tested. By using the fact that the efficiency in the oxygen transfer rate was higher at low airflows, savings of approximately 16 % were achieved. In the second strategy tested, an ammonia-feedback control combined with a DO-feedback controlled the DO-set point in the first aerobic zone. This strategy adjusted the DO- set points to the loading variations, and this gave a decreased airflow of approximately 9 %. Finally the two strategies were combined. All zones were then controlled individually with DO-set points set by an ammonium-feedback and a DO-feedback. The strategy gave savings in the airflow of approximately 18 %. In all three trials the aerated zones were more efficiently used, and the estimated savings are 550 000 SEK/year, and with a preserved nutrient removal efficiency.

Författare

Andreas Thunberg

Lärosäte och institution

Uppsala universitet/Institutionen för geovetenskaper

Nivå:

"Uppsats för yrkesexamina på avancerad nivå". Självständigt arbete (examensarbete) om 30 högskolepoäng utfört för att erhålla yrkesexamen på avancerad nivå.

Läs mer..