
Sökresultat:
1298 Uppsatser om Water scarcity - Sida 11 av 87
Computer Modelling of the Influence of Surface Topography on Water Repellency and a Study on Hydrophobic Paper Surfaces with Partly Controlled Roughness
A computer model based on minimization of the free energy, capable to predict contact angles and spreading transitions between Wenzel and Cassie mode for drops placed on surfaces with different topography were implemented in matlab. Simulations were compared with experiments documented in the literature. These showed that reported transitions between Cassie and Wenzel mode can be explained by minimization of the free energy. In this report, a study on the possibility of constructing water repellent paper surfaces with a combination of treatment with octadecyltrichlorosilane and topography changes, is included..
Studie av skyddsavstånd mellan bergvärmeanläggning och skyddsobjekt i ett vattenskyddsområde
During installation and operation of a geothermal heat pump system leakage of an antifreezing agent can appear in a borehole and leak out in surrounding groundwater. To guarantee high quality drinking water for generations to come Sweden has dedicated some areas as water protection areas. The local authority gives permits for the installation of heat pump systems within water protection areas. Before giving a permit the local authority makes an evaluation of the risks involved in installation and operation of the system within the area. By keeping a certain distance between the protected object in the area and the heat pump system the risk of polluting the protected object with an anti-freezing agent can be reduced.This thesis makes a comparison between three different methods of calculating an appropriate distance between the protected object and the heat pump system.
Sverige och implementering av EU-direktiv : En fallstudie av badvattendirektivet och arbetstidsdirektivet
The aim of this paper is to explain and compare non-compliance of two EU-directives, ?the quality of bathing water? and ?the working time directive?. This study answers the questions: Why didn?t Sweden implement the directive on bathing water quality and the working time directive correctly? Are the reasons for non-compliance the same or different in the two cases? The paper is designed as a case study and with an explanatory attempt we explain why the two directives weren?t implemented correctly in Sweden. The theoretical approach is based on both general- and EU-specific implementation theories.
With a few liters of clean drinking water : a Cost Benefit Analysis of the socio-economic effects from implementing new clean drinking water technologies in rural India
In 2010, Airwatergreen AB started testing their new technology, the Airwaterwell, an atmospherical water generator of their own design that is running on solar heat, with a production capacity of three litres of water per day and m2. The purpose was to focus on foreign aid organizations as main purchasers for project investments towards rural communities in developing countries that suffer from lack of, or compromised quality of drinking water. In order to further understand if this technology would bring a positive impact in the developing countries, the company contacted the Swedish University of Agriculture for a socio-economic study of the Airwaterwells? potential.
The authors elected Cost benefit analysis as the appropriate method for conducting the study and India became the study region because of its many problems with water related issues such as diseases as well as insufficient water supply for households. The regions that this study is based on are Gujarat, Haryana and Uttar Pradesh given their differences in income, health situation and poverty rate.
Elever med Dyslexi : Hur elever med dyslexi har upplevt sin skolgång och datorprogrammet ViTal
The European Water Framework Directive (WFD; 2000/60/EC) was incorporated into the Swedish legislation in 2004 through the ordinance Förordningen om förvaltningenav kvaliteten på vattenmiljön (SFS 2004:660). The objective is that all water bodies shall reach a good status by the year 2015. In Sweden the comprehensive plans of the municipalities can play a large role in reaching these goals. A comprehensive plan deals with the long term water and land use of the municipality, which can facilitate an early consideration of water management in the planning process of the municipality. In Sweden five river basin districts have been established in accordance with the Water Framework Directive.
Skydd mot nitrat och bekämpningsmedel i dricksvatten : åtgärder och styrmedel i fem länder
In many European countries there is an increasing concern about the occasionally
high concentrations of nitrate and pesticides in drinking water. The advent of the EU
Water Framework Directive particularly highlights this. The directive states that all
large drinking water sources should be identified and protected from pollution before
2009 and that by 2015 all water bodies should reach a 'good status'.
In Sweden about 60 percent of the drinking water sources have protection areas. This
means that about 700 new water protection areas need to be designated before 2009.
This will affect many farmers, restricting their farming practices.
The purpose of this study was to investigate which methods are used in other
countries concerning nitrate and pesticide pollution from agriculture. From this, the
expectation was to generate ideas on what could be undertaken in Sweden when
designating new protection areas.
Anaerob psykrofil behandling av hushållsavloppsvatten i UASB : Utvärdering av kapaciteten hos en två-stegs UASB-reaktor för behandling av hushållsavloppsvatten
Hammarby Sjöstad is a new district in southern Stockholm. A main objective with the Sjöstad project was to halve the environmental impact compared to other construction work. The environmental goals involve a halved water consumption rate, a local treatment of storm water and trials aiming to extract nutrients from the waste water. Sjöstadsverket is an experimental treatment plant used for testing new treatment processes for domestic waste water from Hammarby Sjöstad. The results are to be compared with the conventional process used at Henrikdals treatment plant today.
Ut ur Östersjön genom vassen : beskrivning av övergödningsproblematiken samt optimering av en reningsmetod genom skörd av vattenväxter
This study is based on AgroSeas business idea from environmental problems to valuable resource, with the objective to optimize a method to purify the already eutrophicated Baltic Sea by harvesting water plants, mainly reed. The nutrients will then be recirculated to arable land through residues from biogas production. The amount of nutrients that can be removed by harvesting the biomass
depends on the amounts of biomass and the nutrient content of it, which in turn is strongly dependent on the nutrient concentration of the surrounding water. Vegetation suggested in the study for an effective nutrient uptake is helophytes: reed, cattails, reed canary grass, reed sweet
grass in shallower water and lemnoideaes: duckweed and nymphaeids in the deeper parts.
Competitive species has high purification ability but requires regular maintenance to avoid channeling and overgrowth. Regarding time and method of harvest, effectiveness may be improved by: harvesting plants above the water level and after flowering, a border is kept, harvesting twice a season, a bigger machine and a regular maintenance.
This literature has illuminated a major environmental problem and it has been suggested
optimizations for a method for cleaning the Baltic Sea through harvesting water plants, but to get a
definite answer for the optimal method for each site tests should be carried out, this because many
factors determine to what is suitable for each, specific environment.
.
Intelligent vattendesign : utformning av Gjutarplan i Kallhälls centrum
The thesis aims to be an informative study for landscape architects and hopes to contributeto an understanding of ways water can be used and managed at sites lacking open, greensurfaces.The title "intelligent water design" should evoke the reader?s thoughts concerning intelligentaspects of water. Text, images and the design proposition give hints about these aspects.In the first part of this thesis, various examples of water design are presented. The chosenexamples are all applicable in urban environments with a high percentage of impervioussurfaces.The second part examines Gjutarplan, an urban square in the centre of Kallhäll, in Järfälla,north of Stockholm. Gjutarplan is first framed in a geographical and historical context.
Utvärdering av ett värmepumpsystems prestanda till en HWC-tvättmaskin : Med fokus på fläktvarvtal och köldmedieflöde
This report was performed in order to evaluate a new technological measure and focuses generally on a heat pump system to a HWC-washing machine. The client is Asko Appliances AB, a company well known for its environmentally friendly products. The goal of this study was to improve the energy efficiency of a washing machine by combining a heat pump device to the heater of the wash water, in order to reduce the energy consumed for heating the water. Besides reducing the energy consumption in heating the water, the washing machine was required to meet low noise and short operating time specifications. For that purpose, nine trials in three test series have been carried out.
Implementeringen av EU:s ramdirektivför vatten i kommunernas planarbete : En studie av kommunerna i Stockholms län
The European Water Framework Directive (WFD; 2000/60/EC) was incorporated into the Swedish legislation in 2004 through the ordinance Förordningen om förvaltningenav kvaliteten på vattenmiljön (SFS 2004:660). The objective is that all water bodies shall reach a good status by the year 2015. In Sweden the comprehensive plans of the municipalities can play a large role in reaching these goals. A comprehensive plan deals with the long term water and land use of the municipality, which can facilitate an early consideration of water management in the planning process of the municipality. In Sweden five river basin districts have been established in accordance with the Water Framework Directive.
Wallenius waters AOT luftrenare
This bachelors thesis was made forWallenius Water AB to develop a basisfor an Airpurifier prototype. Wallenius Water isone of the world's leading environmentaltechnology companies engaged inchemical-free water treatment based onUV-radiation. The thesis aim was toproduce a basis for a prototype that canbe used in three applications:Standalone, RAS systems and ventilationsystems. The work includes anintroductory description of the theorybehind AOP technology based on aliterature review on the subject. Asurvey of products currently on themarket and a product specification hasbeen used as the basis for thepreparation of a number of concepts inthis report.
Skalkonstruktion : Med inriktning mot hållfasthet och dämpning av ljud
The sound part is mainly practical and is dependent on concepts that have been tested through measuring with a sound level meter. The design part is more theoretical and has been verified with CAD models and finite element analysis.With a sound damping hood on the compressor the sound level is reduced with up to four dB. An optimized absorbent for the compressor space gives a reduction with three dB. By using the insulation for the heat water tank as absorbent we can see a sound reduction on the lover octave bands. A reduction like this is elsewhere hard to achieve as at it requires thick absorbents.By changing the today?s insulation to the heat water tank to a form of polystyrene polymer insulation the weight from the heat pump above can be transferred to the stable heat water tank.
Removal efficiency of perfluoroalkyl substances (PFASs) in drinking water : evaluation of granular activated carbon (GAC) and anion exchange (AE) using column tests, and the effect of dissolved organic carbon
Poly- and perfluoroalkyl substances (PFASs) are a group of environmental contaminants that have gained increasing attention due to their potential to bioaccumulate, environmental persistence and potential toxicity. PFASs have been found in surface water, sediment, air, soil, sludge and ice caps globally, as well as in wildlife and humans. Furthermore, PFASs have also been detected in drinking water, leading to raised concerns for human health, since drinking water is one of the most significant sources of PFASs for the general population. Conventional water treatment techniques have shown to be ineffective removing PFASs, highlighting the importance for further research to develop efficient removal techniques.
The aim of this study was to investigate the removal efficiency of PFASs in water using two treatment techniques; granular activated carbon (GAC), type Filtrasorb 400®, and anion exchange (AE), type Purolite A-600. Additionally, the effect of dissolved organic carbon (DOC) on removal efficiency was studied.
Förutsättningarna för ett parallellt generation IV system vid svensk nybyggnation av kärnkraft.
A new build in the Swedish nuclear power system would entail increased re-quirements for the proposed repository, which is adapted after the reactors of today. With a fast reactor, capable of burning nuclear waste, operating in parallel with the light water reactors, the increased requirements on the repository could be reduced.In this thesis, simulations of a light water reactor and a fast reactor have been performed by using the Monte Carlo code Serpent to investigate the changes in the fuel inventory. The light water reactor in the study is a boiling water reactor and the fast reactor of the type sodium-cooled fast reactor and they have been used for three different operation scenarios.By studying the fuel composition and the results from the simulations of the three scenarios conclusions can be drawn. Conclusions regarding the change of the fuel inventory and decay heat in Clab as well as the interim storage facility and in the repository. Depending on the operation alternative the changes dif-fered significantly and especially regarding the mass of burned actinides for different fuels in the fast reactor.The lowest increase of fuel assemblies was meet when using 50 years old fuel with 20MWd/kg U burnout and 2,0 % enrichment for start up of the fast reactor and 30 years old fuel assemblies with 50MWd/kg U burnout and 4,7 % enrichment for the further operation of the reactor.The increase of the number of fuel assemblies was 3174, which is equivalent to 641tons of heavy metal.