Energihushållning och varsamhet för äldre byggnader : Chefsbostaden i Strömsholm, ett timmerhus från 1900-talets början
This report is the result of a degree project in building engineering, at an advanced level. The project evaluated a building from a technical and historical point of view, and focused on its energy consumption, particularly the energy used for heating. The building in question was a small apartment building in Strömsholm, Sweden. It was made in 1902, from vertical logs, a not so common form of the traditional log house. The goal of the project was to evaluate if the energy consumption could be reduced in accordance with building preservation regulations, that is without damaging any of the building?s cultural or historical values.The building was surveyed with the help of archive and literature studies, interviews and inspections.
Energieffektivisering - Laholms kyrkliga samfällighets kulturhistoriska byggnader
Energy efficiency is today more important than ever, mainly due to the high energy prices and the approaching climate changes. Heating of buildings is an essential area within energy efficiency. Many buildings are old and were built at a time when the energy prices were low and the term ?energy efficiency? was unheard of. By applying today?s broad range of energy saving actions on these old, and thereby often, heating ineffective buildings, this area has a large potential in reducing energy consumption and costs.Churches and chapels are generally old buildings with, in many cases, ineffective heating systems and therefore consume much more energy than needed.
Lågenergihus : Att bygga energisnålt
A large proportion of the energy consumption is in the building industry and a large part goes to heating our homes and premises. In the developing countries' development now threatens the large consumption of energy in our earth's climate. It is in the West world that we must be good role models in terms of energy efficiency. One solution to reduce energy consumption for heating of buildings may be to continue to build low energy houses and passive houses, but it is also about rebuilding the buildings that currently have high energy consumption such as the old Million program Houses. These buildings will be standing many years and their energy consumption will not diminish over time by itself and energy prices will certainly not diminish in the future.
Nutidens ventilationssystem i lantbrukets lösdriftstallar : En undersökning av sex stycken ventilationssystem
Den traditionella båsladugården har idag utvecklats till lösdriftstallar där korna har fri tillgång till foder och liggplatser. Korna mjölkas i antingen mjölkgrop, karusell eller av en robot. För att uppnå bra termisk komfort i lösdriftsstallen så använder man sig av naturlig eller mekanisk ventilation. I detta arbete så undersöks några olika ventilationssystem som använder sig av naturlig ventilation på fem utvalda kostall för att se hur de fungerar i praktiken. Detta görs med fukt- och temperaturmätare och med rökpatroner för att se hur luften rör sig i stallet.
Delårsrapporter - osäkerheter och bedömningar i praktiken
certain building or environment can get a protection as a notable building if it contains certainvalues. These values are established by a certain category of people from the cultural sector.These people use established criterions to define the cultural value of the object. The objects canbe evaluated differently depending on who has done the evaluation. The people who protect thecultural environment and choose which buildings that are to be defining as notable buildingsoften uses a special model to characterise the different cultural values. This model is produced bya man called Axel Unnerbäck.
Low Temperature Waste Heat Solutions : with proposals for energy technological actions based on Scania?s building 64
The report comprises two separate parts:part 1: Temperature needs for district heating in the paint shop for axles in building 210part 2: Energy and low temperature waste heat solutions in heating and cooling systems for building 64 with surroundingsThe paint shop for axles in part 1 has air quality requirements in places for coating of axles. Toachieve desired air properties there are different process ventilation systems, which consist ofventilation coils for heating and cooling, plus air humidifier. The ventilations coils for heating usedistrict heating. Today the ventilation coils use water of 100°C to achieve necessary air demands inthe coating boxes. This part of the report investigates whether the existing system would achievethe air requirements with a water temperature of 75°C instead of 100°C in the ventilation coilsduring the coldest parts of the year.
High-rise buildings; structural design, prefabrication and logistics
In the report we have investigated four high-rise buildings with the intentions to find out witch parts are prefabricated and what relation can be found between structural design, prefabrication and the logistics. After the investigation we noticed that the grad of prefabrication in each one of the projects is good in relation to what purpose the building have and the given background. During the report we found that layout ? structural design ? prefabrication ? logistics is an order that we think can make the production of the building more effective if followed. We believe that the prefabrication of high-rise buildings have potential to grow and get more optimized in the future..
Energieffektivisering av modern tillbyggnad till äldre skola : fallstudie från Österbyskolan i Österbybruk
The Swedish government has introduced a goal to reduce the energy intensity by 20% to the year 2020. To reach this goal actions need to be taken throughout the energy sector which includes residential and commercial buildings. This thesis considers the possibility to reduce the energy usage in a building located close to Uppsala. The analyzed building is a combined office, cafeteria and entrance and was completed about half a year before this project started. Therefore the measures presented for a more energy efficient building are presented as measures for future constructions.Simulations have been made in VIP-Energy, a dynamic energy calculation program.
Sjuksköterskors kommunikation med patienter som vårdas i respirator : Nurses? communication with patients during mechanical ventilation
Aim: The aim of this study was to describe intensive care nurses? experiences communicating with patients during mechanical ventilation.Methods/design: A qualitative interview study. Interviews where analyzed using descriptive content analysisSetting: Nine intensive care nurses from two different intensive care units were interviewed using a semi structured interview guide.Background: Past research has shown that patients during mechanical ventilation in the intensive care unit, feel very vulnerable and the helplessness of being unable to speak. These patients feels that they are completely dependent on the nurses and their competence. It has been shown to be very important that the patient feels included, acknowledged and respected.Results: The analyzed data resulted in a theme; through communication strive to preserve patients´ dignity and three main categories; create relationship to the patient, minimize patients´ vulnerability and don´t give up.
Inomhusmiljöproblem i fuktiga byggnader : En utredning av åtgärder vid fuktrelaterade inomhusmiljöproblem
Dampness in the indoor environment have been a major issue of discussion the last decades since more and more people complain about their indoor environment. In the present situation there are difficulties to find what causes people?s discomfort in a damp environment even though there is a strong connection between dampness and human health.The aim of the thesis was to contribute to the work done today to achieve a better indoor environment in damp buildings. The purpose of the work was to evaluate whether the measures issued for dampness in the indoor environment contributes to the improvement of health and environment for those who are living or working in that space. Through a literature review, interview and survey the following three questions were answered to achieve the aim and purpose:How are people affected by the indoor environment in damp buildings?Which are the measures issued to prevent dampness in the indoor environment?Do these interventions contribute to a better indoor environment?How people are affected by the indoor environment in damp buildings and how these problems are prevented were the foundation for the continued work with the survey.
Energianalys av luftbehandling
Elanvändningen till ventilation har ökat med 40 % sedan 1990 i Sverige. Ventilationen är en miljöbov enligt undersökningar som visar att elanvändningen till ventilationssystemens fläktar kan reduceras. Minskning av elförbrukningen kan t.ex. uppnås genom utbyte av fläktmotor till en EC-motor eller till en fläkt med bakåtböjda skovlar och direktdrift. Effektivieringsåtgärder kan ge en lägre elförbrukning på upptill 50 % i vissa applikationer.Ventilationsfläktarna i Sverige förbrukar 12,3 TWh per år.
Design and evaluation of an AGV-system for Tetra Pack in Lund using simulation
This examination work is the final work in our education to become a Bachelor of Science inMechanical Engineering by the University of Lund.The main purpose with this work has been to develop a new effective material handling system for TPPM AB in Lund since the existing system starts to become out of date. The future system that is going to be installed shall have the capacity to support all machines with unit-, semi- and finished goods during full production. The work has also included studying the possibilities to change the material flow in a positive way between the storage and the production when one is using existing buildings.During our work we have been used a simulation program called AutoMod, performing company visits, interviews and reviewed internal and external information to create a picture of what the best conclusion can be. During the work we have contacted five suppliers to receive system solutions and quotatioris. The suppliers, which have been contacted, are Swisslog, Moving, Rocia, Christensen & Hansen and ABB.
Aktiv bullerdämpning i ventilationssystem
Active headsets have been on the market for years and now it is time for something else to enter the stage. The technology of active noise reduction can for exmple also be used in ventilation systems for reducing ventilation noise. An active control system principally consists of four important components, namely the downstream error microphone, the upstream detection or reference microphone, the digital signal processor (DSP) and a loudspeaker. The upstream reference microphone listen to the primary ventilation noise and sends it to the DSP which makes a phase shift to the signal and sends it to the loudspeaker. The loudspeaker sends out the opposite waveform of the incoming one and reduce the primary ventilation noise.
Inhysningsrelaterade faktorer som påverkar förekomsten av luftvägsinfektioner hos kalvar
Luftvägssjukdomar är ett av de vanligaste hälsoproblemen hos kalvar och utgör en betydande kostnad för branschen. Luftvägssjukdomar är komplexa till sin natur och uppkommer endast då en kombination av faktorer som inkluderar djuret, miljön och infektiösa agens förekom-mer. Ofta är den primära patogenen ett virus och den påföljande lunginflammationen orsakas av bakterier. Ett bidragande virus, BVDV, har genom ett frivilligt kontrollprogram utrotats i Norden och det finns potential att utrota även BRSV. Genom en ökad förståelse för biosäker-het och hur ventilation av mikromiljöer, gruppstorlek och ålderssammansättning påverkar smittrycket och luftvägshälsan hos kalvar kan byggnader och management-rutiner som mini-merar risken för respiratoriska sjukdomar utformas..
Kommunikation hos respiratorvårdade patienter : Upplevelser hos patient och vårdpersonal samt analys av samtal med och utan röstgenerator
?Studies have shown that patients receiving mechanical ventilation in an intensive care unit (ICU), who are entirely dependent on the nursing staff, often experience frustration due to a temporary loss of the voice source. Limited communication is an important factor contributing to patient discomfort. Nursing staff also report communication as frustrating and difficult.The aim of the present study is to introduce a neck-type electrolarynx as a communication aid in an ICU, to study the nursing staff experiences of communication with tracheotomized patients receiving mechanical ventilation, and to examine the patient´s experiences regarding communicative abilities. Communication between a ventilator treated, tracheotomized patient and members of the nursing staff was recorded and analyzed according to principles of Conversation Analysis (CA).The results show that several members of the nursing staff experience difficulties communicating with tracheotomized patients receiving mechanical ventilation.