Norrkila arena : visuell beskrivning av arena

A home for elderly is planed to be built at Zakrisdal, Karlstad, Sweden. The heat source for the building was at the time not determined. In order by the local government of Karlstad this report is meant to examine if the need of heat could be provided only by solar heat combined with a seasonal heat storage. The problem to solve is, if the need of heat from the home for elderly is provided from only solar heat, whitch dimensions of the solar collectors and the storage is needed?.

Solmodul jord- och bergvärmepump

An increasing number of heat pump producers have developed heat pumps that can be connected to solar panels. In this thesis we have examined the possibilities of connecting solar panels to existing ground source- and geothermal heat pumps that has not been adapted to solar panels. During the work process, a prototype plant has been built to compare our theory with the practical results and with our designed sizing tool. The work has rendered in knowledge that will be used to build a sun module that can be easily connect to the existing heat pump system. The existing heat pump, our test plant, has been supplemented by an advanced storage tank used to allow different operating modes.

Ventilationseffektivisering i skolbyggnader :

Studien går ut på att jämföra tre olika styrsystem för ventilation, nämligen CAV (Constant Air Ventilation), VAV (Variabel Air Ventilation) och DCV (Demand Controlled Ventilation). Dessa styrsystem ställs mot varandra i tre olika lokaltyper, med syfte att identifiera det mest energieffektiva styrsystemet. Ett syftet med studien är också att upptäcka vid vilka flöden det lönar sig att arbeta med VAV- och DCV-styrsystemen..

Low Temperature Waste Heat Solutions : with proposals for energy technological actions based on Scania?s building 64

The report comprises two separate parts:part 1:  Temperature needs for district heating in the paint shop for axles in building 210part 2:  Energy and low temperature waste heat solutions in heating and cooling systems for   building 64 with surroundingsThe paint shop for axles in part 1 has air quality requirements in places for coating of axles. Toachieve desired air properties there are different process ventilation systems, which consist ofventilation coils for heating and cooling, plus air humidifier. The ventilations coils for heating usedistrict heating. Today the ventilation coils use water of 100°C to achieve necessary air demands inthe coating boxes. This part of the report investigates whether the existing system would achievethe air requirements with a water temperature of 75°C instead of 100°C in the ventilation coilsduring the coldest parts of the year.

Kombinerat system för ventilation och rumsuppvärmning : Parameterundersökning i simuleringsmodell för takvärmesystem

A large amount of our time is spent indoors in an artificial climate. To make the experience pleasant there are requirements on the ventilation and the heating system. At the present time the most common form of heating is a radiator system complemented with a ventilation system. A ceiling heating system with combined heating and ventilation can replace the two separated systems. The benefit with a ceiling heating solution is that it saves space since the radiator system is no longer needed.

Energiberäkningar för passivhus

AbstractClimate and environmental issues are of paramount importance. Researchers agreethat we must all contribute to a reduction of gases that contribute to climatechange. Energy consumption must decrease within all sectors and the promotionof renewable sources of energy must be introduced.Each sector should aspire to decrease its energy consumption. Energyconsumption is strongly linked to waste gases that contribute to climate change.Passive houses are a part of the construction industry's methods to attain energyconservation.Passive houses are derived from low energy houses and super insulated houses. Apassive house is intended to obtain heat from the inhabitants and through theiractivities.

Solenergi och värmelagring i kvarteret Lagern

Humanity stands before a huge challenge to lower its emissions of carbon dioxide and its use of energy at the same time as the global population is rising and the developing countries are being industrialized. A lot of newly built buildings are due to this challenge, designed to be more energy efficient but also use renewable energy resources instead of pollutant fossil fuels .Solar energy is one of the purest forms of energy that exists in abundant amounts, which is why it is most likely that it could come to play a major part in the future energy market. The main purpose of this report is to investigate the possibility to implement a sustainable energy system with solar thermal heat and  heat storage as main sources of energy in the neighborhood ?kvarteret Lagern?, which is the area where the old football stadium ?Rasunda Stadion? was located. New developments within different heat storage techniques have opened up new approaches to enable buildings an all year round heat supply from solar energy. This report will focus on heat storage in boreholes. At the present here is only a preliminary plan of how the neighborhood is supposed to be designed.

Skillnad i energiförbrukning vid byte från CAV-system till VAV-system i en kontorsbyggnad

Detta arbete är utfört hos Videum AB i Växjö i syfte att visa på skillnader i energiförbrukning mellan deras ventilationssystem samt hur lång tid det skulle ta för en möjlig investering i ett nytt ventilationssystem att återbetala sig.För att uppnå detta utfördes beräkningar på olika faktor som bidrar till den totala energianvändningen hos ventilationssystemet. I denna undersökning behandlas fläktar, golvaggregat och värmeförluster genom ventilation. Den största påverkande faktorn i den totala energiförbrukningen är värmeförluster genom ventilation.Resultatet av vår undersökning visar att det är billigare att använda i VAV-system än ett CAV-system under rådande förhållanden enligt våra beräkningar. En årlig besparing på 29465 kronor per våning vid byte från CAV-system till VAV-system uppnås. Det är värt att byta ventilationssystem även fast att investeringskostnaden inte sparar in sig under dess livstid.

New Business Model for District Heating Firms Stabilizing the National Energy System with a Future Variable Electricity Production

The aim of this thesis is to develop a new business model for district heating and cooling firms which can contribute to a stabilization of the Swedish national energy system. The business model is developed for a district heating and cooling firm and is exemplified with Fortum Heat. The theoretical investigation around the topic creates a rigid base for following qualitative empirical studies. Osterwalder?s canvas for business model generation is used together with a Casual Loop Diagram to identify a number of business opportunities which stabilizes the national energy system.

Aktiv bullerdämpning i ventilationssystem

Active headsets have been on the market for years and now it is time for something else to enter the stage. The technology of active noise reduction can for exmple also be used in ventilation systems for reducing ventilation noise. An active control system principally consists of four important components, namely the downstream error microphone, the upstream detection or reference microphone, the digital signal processor (DSP) and a loudspeaker. The upstream reference microphone listen to the primary ventilation noise and sends it to the DSP which makes a phase shift to the signal and sends it to the loudspeaker. The loudspeaker sends out the opposite waveform of the incoming one and reduce the primary ventilation noise.

Osäkerheter vid brandteknisk dimensionering av ventilationssystem

This masters thesis deals with smoke spread via ventilation systems. One aim of the thesis is to investigate and explain the differences in efforts to prevent smoke spread via ventilation systems in different countries. A second aim of this thesis is to investigate how frequently occurring smoke spread via ventilation systems in Swedish buildings are. A third aim is to investigate how uncertainties in input variables to smoke spread calculations will affect the result of calculation. To be able to do this the most important input variables are identified and analysed.

Optimerande av gasanläggning - genom värmeåtervinning och förlustreducering. Gässlösa Reningsverk

The municipality, of Gatukontoret in Local government of Borås has in the long run, a required need to look after the current heating devices (the gas production plant) in sewage treatment plant, called Gässlösa. The practical work of the examination is about, trying to find a better way to take care of the current heat recovery. That may be one way or another, rather easy to implement in the existent construction.Through the work to increase the efficiency of the gas engine, implement of some external cooling system by heating exchange device. That gives an opportunity to heat (primary) the digester, (but even all internal public areas) with its own superfluous heating.The report shows that if the management group may invest 422 704 crown to implement a heat exchanging device, it gives more space to reduce the need to buy expensive external energy. Gatukontoret´s pay off time, for buying machines, is 20 years, with reservation to calculate with 4 percent internal interest, leads to the yearly mount of 31103 crowns.If Gässlösa increases the gas engine time in (effective) duty approximately (correspondingly) 48 hours a month the entire investment will generate a profit in January in year seven after the implementations.

Renovering av flerfamiljsbostäder inom miljonprogrammet ur ett energi- och lönsamhetsperspektiv

Miljonprogram is a Swedish building program from 1964 to 1975. During that time about a million homes were constructed. Now, almost 50 years later, they are in desperate need of renovation. In order to fulfil the Swedish environmental objective to decrease energy consumption 50 per cent until 2050, considerable housing stock built under the Miljonprogram has to be renovated.Focus in this thesis is on the building services and theirs profitability that can decrease energy consumption in households build during the Miljonprogram. Building construction is not considered in this report.

Aktiv bullerdämpning i ventilationssystem

Active headsets have been on the market for years and now it is time for something else to enter the stage. The technology of active noise reduction can for exmple also be used in ventilation systems for reducing ventilation noise. An active control system principally consists of four important components, namely the downstream error microphone, the upstream detection or reference microphone, the digital signal processor (DSP) and a loudspeaker. The upstream reference microphone listen to the primary ventilation noise and sends it to the DSP which makes a phase shift to the signal and sends it to the loudspeaker. The loudspeaker sends out the opposite waveform of the incoming one and reduce the primary ventilation noise.

Ökad resurseffektivitet i kraftvärmesystem genom säsongslagring av värme

Increased resource efficiency in an energy system could result in large economic and environmental benefits. Tekniska verken i Linköping AB (Tekniska verken) is responsible for the district heating network in Linköping. Their vision is to create the world?s most resource efficient region. An important step towards this vision is more efficient usage of produced heat, something which could be achieved through integration of a seasonal heat storage in the energy system.