Sökresultat:
9524 Uppsatser om VBX; Ventilation-system; Heat recovery - Sida 3 av 635
Energieffektivisering i flerbostadshus för studentboende
Uppsalahem AB is a municipally owned real estate concern that owns and administrates housing for nearly 30 000 people. The company puts a lot of effort into reducing the energy use of their housing stock. This project is a master?s thesis in the energy systems programme at Uppsala University, carried out in collaboration with Uppsalahem. The aim of this thesis is to provide energy saving measures for fourteen student housing buildings in Uppsala, Sweden.
Detektering av mänsklig närvaro i inomhusmiljö
One problem in today?s indoor air quality lies within insufficient ventilation. Dynamic ventilation can be obtained by implementing a Demand-Controlled ventilation (DCV) system. DCV systems adjust the ventilation in a building by calculating the impact made by its? occupants.
Värmeåtervinning på förskolan Rymdattacken 1 : En jämförelse av värmeväxlare
In the spring of 2014 Sweco Systems AB were commissioned to design a ventilation system for a newly built preschool in Linköping. Terms from the client was that it cost efficiency would cope with the energy demands that are placed on the building. The unit chosen was a cross-flow heat exchanger, and this work is to compare it with two other heat exchangers to see if a more energy and cost efficient could have been chosen. The heat exchangers that was chosen for the comparison was a rotating- and a counterflow heat exchanger. Simulations have been made to the different heat exchangers by the manufacturers.
Luftfuktighetens påverkan på konstruktion och klimat i en berghangar
Aeroseum is an aviation museum located in an old military underground hangar. The ventilation system in the hangar is designed for the military purpose of the hangar. This design includes a solution with air flowing through the space between the construction of the hangar and the rock surface. The solution is intended to avoid a buildup of inflammable gases. This design leads too high humidity levels in the hangar.
Projektering av ett småhus samt ekonomisk jämförelse av värmesystem
Design of a house requires knowledge of both technology and economics. Heating and ventilation shall be designed, costs are calculated and estimated and requirements must be fulfilled. Which heating system is to be elected is also a difficult choice, especially with rising energy prices as a factor.The choice of energy system is not always given, because it depends on several factors. Below is a comparison between district heating, geothermal heat pump and electric boiler from an economic standpoint. In a previous report appears district heating and geothermal heat pump as the best options.
Analys av sorptiv kylning i industri- och kontorsbyggnader
Energy efficiency is important both to reduce costs and to reduce greenhouse gas emissions in the atmosphere. Reducing costs will also help maintain business competitiveness.Scania in Södertälje is a company where the optimization of energy use is an ongoing and continual process. One area with potential to make energy and cost savings is the effectiveness of the ventilation systems in offices and industrial premises at Scania. During the summer months an increased demand for cooling occurs, leading to increased ventilation and a peak in district cooling system usage. Sorptive cooling is a technology where the supplied air is cooled by applying external heat.
Ombyggnation till passivhus
Energy issues are constantly increasing attention in today's society. People's impact on Earth isentered in more contexts. Many discussions are about how the entire social structure needs to bestreamlined in order to achieve sustainability. The residential and service sector accounts for 39 % oftoday's total energy consumption in Sweden and the increasing electricity prices have made buyersmore interested in energy issues.There are many buildings in need of refurbishment today, including all the apartments that werebuilt in the 1970s to reduce the housing shortage at the time. 650 000 apartments of one millionapartments were built during the so-called the one million program and is currently in need ofrefurbishment.
Frånluftsåtervinning i ett äldre flerfamiljehus : Hovgården - Borlänge
I detta examensarbete undersöktes möjligheten att installera värmeåtervinningssystem för ett flerfamiljehus i Hovgården som ligger en bit utanför Borlänge. I rapporten redovisas två olika sätt för energibesparingar som är aktuella för att ersätta borttagning av oljepannan som används i huset i dag. En rad svårigheter dök upp under undersökningen för installation av nytt värmesystem. Lämpliga lösningar kunde hittas efter mycket analys. Syftet med rapporten var att undersöka möjligheten och lönsamheten för installation av något av följande system; FVP eller VBX-modul som kan återvinna värme ur frånluften.
Livscykelanalys för koldioxidutsläpp från flerbostadshus
Today, about 15 to 20 percent of Sweden?s total emission of carbon dioxide can be traced to the household sector. By examining apartment blocks in a life cycle perspective, the origin of the carbon dioxide emission has been charted and analyzed. This information has been used to create a computational model that calculates the total emission of carbon dioxide from a specific apartment block. The results from the analyzed apartment blocks indicate that both the use of energy and the emission of carbon dioxide have been reduced since the 1960s. Through the examination of building materials, it is possible to lower the emission of carbon dioxide that origins from the construction phase of an apartment block.
Brännkammare för träpulver : Teoretisk analys och praktisk försök
The thesis describes a completely new biofuel system to generate particle-free heat from combustion of ash-containing biofuel particles at high temperatures.The suggested system gives opportunities to introduce biofuels in new areas.Main components in the suggested system is a heat radiating combustion chamber intended for pulverized wood, combined with regenerators to extract heat from flue gases and simultaneously preheating the combustion air.The thesis contains a description of the suggested system, theoretical considerations, calculations regarding the combustion, and includes results from tests performed.The results from calculations and tests performed concludes that the system is workable and possible to apply..
Värmestyrning I Handske
This rapport is result of a project. The purpose of which was to design a circuit that is used in a heat glove. The heat glove is the technical aid which provides heat inside a glove.It is specially suited for old people who have problems with cold hands because of decreased blood circulation.There already was an old circuit in the glove that gives a constant current which develops heat from battery to glove through a circuit. The temperature is between 32 and 34 degrees.The problem with the existing circuit was to regulate the temperature. There is only on/off switch and there is no way to adjust desirable value of the temperature.In order to solve the problem the old circuit was investigated.
Effektiv lagerstyrning genom tillförlitlig prognostisering : Effective inventory control through reliable forecasting
This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.The background of the problem with moisture is that today?s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate.
Effektivisering av energianvändningen i en förskola
This rapport contains an examination of the energy consumption of a kindergarten, which areas that have the largest impact on the energy consumption and what can be done to reduce those areas in ways that are relatively easy and profitable. It is also analyzed if it is possible to reduce the energy consumption from today?s consumption to a consumption that fulfils the demands placed on low energy houses by FEBY.The focus has been on reducing the energy consumption of the areas ventilation, heating system and hot water system, since those seemed to be the easiest ones to affect and since the building is quite recently built.There are different kinds of ventilation systems, at the moment the building have a CAV-system, which means that the ventilation is too high during large parts of the day. There are different ways to manage the ventilation system, for example presence detection, humidity sensors, CO2 sensors, temperature sensors and season adjustment. Many of those are in the end dependent on CO2 sensors to guarantee a good indoor climate, therefore the focus have been placed on this system.
Tätning eller ventilering mot fukt på kalla vindsutrymmen
This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.The background of the problem with moisture is that today?s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate.
Effektivisering av lagringsplatser. Ett förbättringsprojekt på Mekpart AB
Aeroseum is an aviation museum located in an old military underground hangar. The ventilation system in the hangar is designed for the military purpose of the hangar. This design includes a solution with air flowing through the space between the construction of the hangar and the rock surface. The solution is intended to avoid a buildup of inflammable gases. This design leads too high humidity levels in the hangar.