Energimässig jämföelse med investeringskalkyl av två förskolor

This thesis includes an energy survey of the Herrgården pre-school, which has a modern heating- and ventilation system, and a comparison with Östers pre-school which has an older system. An energy survey of Östers pre-school has already been done by a group of three students and all the calculations and values have been collected from that survey. As of today, both pre-schools are heated thru district heating. It will be much easier to make smart and feasible energy-saving-measures by first conducting the energy survey.Herrgården pre-school in Gävle houses 81 children, therteen teachers, one cleaner and one cook. It was finished in the middle of 2009 and the staff has been very pleased with the in-door climate.

Kompaktaggregat till Passivhus i Sverige

Kompaktaggregat är ett integrerat FTX- och FVP-system som används i passivhus. Vi har gjortenergiberäkningar i programmet VIP+ för att se hur kompaktaggregatet skulle kunna fungera ipassivhus i Sverige.De resultat vi har fått fram ur VIP+ visar att passivhus med ett installerat kompaktaggregat klararav att nå passivhuskraven ända upp till Skellefteå. De beräknade värdena understiger kraven förpassivhus, men en viss marginal behövs för att kraven ska nås även efter uppförandet avbyggnaden. Vi har även tolkat tekniska uppgifter på ett sätt som enligt oss har en positiv effektför passivhus på kallare orter. Därför tror vi inte att värdena för de tre nordligaste platserna ärhelt tillförlitliga.

Robot-Assisterad Gradningscell med Force Control

This thesis includes an energy survey of the Herrgården pre-school, which has a modern heating- and ventilation system, and a comparison with Östers pre-school which has an older system. An energy survey of Östers pre-school has already been done by a group of three students and all the calculations and values have been collected from that survey. As of today, both pre-schools are heated thru district heating. It will be much easier to make smart and feasible energy-saving-measures by first conducting the energy survey.Herrgården pre-school in Gävle houses 81 children, therteen teachers, one cleaner and one cook. It was finished in the middle of 2009 and the staff has been very pleased with the in-door climate.

Förbättrad tillgång till referensmaterial vid röntgentolkning

This thesis includes an energy survey of the Herrgården pre-school, which has a modern heating- and ventilation system, and a comparison with Östers pre-school which has an older system. An energy survey of Östers pre-school has already been done by a group of three students and all the calculations and values have been collected from that survey. As of today, both pre-schools are heated thru district heating. It will be much easier to make smart and feasible energy-saving-measures by first conducting the energy survey.Herrgården pre-school in Gävle houses 81 children, therteen teachers, one cleaner and one cook. It was finished in the middle of 2009 and the staff has been very pleased with the in-door climate.

Utvärdering av magnetiska alternativ till optisk scanning

This thesis includes an energy survey of the Herrgården pre-school, which has a modern heating- and ventilation system, and a comparison with Östers pre-school which has an older system. An energy survey of Östers pre-school has already been done by a group of three students and all the calculations and values have been collected from that survey. As of today, both pre-schools are heated thru district heating. It will be much easier to make smart and feasible energy-saving-measures by first conducting the energy survey.Herrgården pre-school in Gävle houses 81 children, therteen teachers, one cleaner and one cook. It was finished in the middle of 2009 and the staff has been very pleased with the in-door climate.

Analys av energiförbrukning, Akzo Nobel Functional Chemicals AB

The main purpose of this project was to make a survey of the steam and electricity consumption at Akzo Nobel Functional Chemistry AB and give suggestions of how to minimize them. These three different areas were focused on. First to make a survey of all the most important consumers, second to find the electricity consumption of the air compressors and the amount of waste heat produced from them. The third area was to calculate a model of how much fresh water that is used during a cooling sequence in the water based heating/cooling system of the reactors and give a suggestion of a suitable reuse for this water.The main result is a total survey of the energy consumption in steam and electricity. The survey shows that the second largest group after drying is heating of ventilation which gives big potentials of reducing the total steam consumption if there is a way of being self supporting in ventilation heat.

Vätskekopplade värme- och kylåtervinningssystem Utveckling av ett verktyg för energiberäkningar

According to a decision of the European Commission, measures are to be taken to reduce the use of energy in the EU. The goal is to reduce it by 20 % compared to the current use. This shall be done to the year 2020 (European Commission, 2011). One industry that use large amounts of energy is the construction of buildings which account for almost a third of the energy use (Brogren, 2012). The major part of the energy that is used in the construction industry is not used when the buildings are built, but rather during the rest of their subsequent lifetime.

Renovering av flerbostadshus - en studie om energieffektivisering och lönsamhet

In today?s society a large focus is put on energy systems and how our energy systems are built up. In order to make sure that we in the future still can enjoy the living standards that we are used to today, Sweden and EU have made a number of decisions on making our energy system more energy efficient and consequently reduce the usage of energy resources. By 2020 the European Union should have reduced its energy consumption by 20 % compared to 1990?s level, and by 2050, 50%.

Kravspecificering av avgaspannor

This report describes the work of developing a specification of requirements for Waste Heat Recovery Units. The main part of the paper describes how the work with the specification of requirements has been performed. One specific question to be answered is:What are the customer?s demands in case of properties for the Waste Heat Recovery Units and how is that information collected as an order documentation to suit the business area Oil & Gas?The report begins with a description of the assignment and continues with the aim and background. A theoretical part describes the different areas and methods that have been important during the process.

Att ta fram underlag för val av luftbehandlingssystem med återvinningssystem i Förvaltarens fastigheter

Sverige och EU har man som mål att halvera energianvändningen fram till 2050 och det arbetet måste starta nu. Det är 15 miljoner kvm byggyta som måste halvera sin energianvändning varje år och i 40 år framåt. Redan idag är 70 % av alla hus till 2050 byggda, vilket innebär att även om vi skulle bygga passivhus fram tills dess skulle det inte räcka för att nå målet. Det är alltså en stor utmaning att halvera energianvändningen till 2050. En jämförelsestudie har genomförts mellan två värmeåtervinningssystem.

Värmeåtervinning ur spillvatten : En utredning av möjligheterna med spillvattenvärmeväxlare

The purpose of this report is to investigate the possibilities with drain water heat recovery (DWHR) in residential buildings. Information and relevant theory has been collected and summarized in this report. Calculations have been done for given scenarios to evaluate profits. DWHR heat exchangers use simple technology and have long life-time. The heat exchanger is connected to outgoing drainage pipe and incoming cold-water supply so countercurrent flow is accomplished.

Potential för värmeåtervinning från mjölkkylanläggningar

The present climate discussion has made energy efficiency an interesting topic. Saving energy does not only help the climate but also saves money for the energy consumer. The purpose of this thesis was to examine the potential of heat recovering from milk cooling. Two milk farms, one with voluntary milking system, VMS, and the other with conventional milking system was used to measure interesting temperatures and electricity consumptions. The numbers were used both to do theoretical calculations and to construct a SIMULINK model. To calculate the potential for heat at milk farms theoretical calculations were made in MATLAB using a reference farm with different combinations of heat recovery and pre cooling. The farm was assumed to keep a dwelling house with the annual heat consumption 18165 kWh.

Tilla?mpning och simulering av naturlig ventilation : Potential fo?r utnyttjande i kontorsrum

Mechanical ventilation is the most common type ofventilation in newly constructed office buildings. Therehas been an interest to utilize natural ventilationinstead of mechanical ventilation among architects andHVAC consultants in recent years. This is due to thesize of mechanical ventilation systems, which arespace consuming. The mechanical ventilation system isalso complex and requires maintenance. Furthermore,the fan uses a considerable amount of energy.

Utvärdering av energieffektiviseringsåtgärder på Bokelundskolan i Växjö

The purpose with this report is to examine how the implemented energy efficiency measures on Bokelundskolan in Växjö have had impact on the energy use. The measures which have been implemented are, new ventilation system, new heating system, optimized adjustment of the heating system, new windows with U-value 1.2 and lower window height, insulation under windows and in the crawl space. The school's energy use before and after rebuilding has been calculated with the calculation program, Vip-Energy 1.5.5.Calculations of energy use for the school with windows on U-value, 0.9 and 0.7 have also been done. The replacement of windows has been studied from a cost perspective. The conclusion is that the exchange of heat and ventilation system was the biggest contributor to reduced energy use on Bokelundskolan.

Kartläggning av material flödesflaskhals i ICA butik.

In the spring of 2014 Sweco Systems AB were commissioned to design a ventilation system for a newly built preschool in Linköping. Terms from the client was that it cost efficiency would cope with the energy demands that are placed on the building. The unit chosen was a cross-flow heat exchanger, and this work is to compare it with two other heat exchangers to see if a more energy and cost efficient could have been chosen. The heat exchangers that was chosen for the comparison was a rotating- and a counterflow heat exchanger. Simulations have been made to the different heat exchangers by the manufacturers.