Uppvärmd konstgräsplan : Beräkning av utnyttjningstid för en uppvärmd konstgräplan med alternativa rörplaceringar
For Skattkärr IF a turf field with warming has been projected to increase field?s utilization hours and to have a longer period for athletes to perform their activities outdoors. The technique chosen to heat the plan is a type of a geothermal heating system without a heat pump. The brine, which is water with 30% ethanol, collects heat from the borehole and discharges it to a coil in the field. There is at position 11 boreholes but it is planned to increase the number to 31, which is the design for the facility.
Spillvärmeåtervinning ur kylvattensystemet ismältverket på Sapa Profiler AB i Sjunnen
The smelting process at Sapa Profiler AB in Sjunnen generates large quantities of waste heat which is absorbed by the cooling water when the aluminum is cooled down. This paper is the result of a Master?s Degree Project aiming to present the conditions for recycling the waste heat. The cooling water absorbs the heat from the aluminum at an average rate of 600 kW and the paper shows that it can be used to replace electrical power consumption for heating the production plant?s facilities.
Hundhållning i bil : situationen i Sverige och effekter av utetemperaturen. Enkätundersökning och experimentell studie
The aims of this project were to describe the circumstances around dogs being left alone in cars, to investigate owners? knowledge of the risks associated with leaving dogs in cars and the relevant legislation and, finally, to study how changes in the air temperature and air composition in the car affect the dog. The project consisted of a survey of the literature, a questionnaire part and an experimental part.
An important conclusion is the importance of the level of knowledge of owners, since there are several ways in which an owner can prevent their dog from heat stroke and, in the case of an eventual accident, their action can have direct consequences in minimizing the long-term damage to the dog and even whether or not it survives. Fewer than half of the owners in the study knew that for a dog suffering heat stroke, the most important thing is to bring the body temperature down. Only a third of dog owners knew that if a dog is left in a warm car and showing signs of heat stress, then the police should be contacted and the dog quickly helped out of the car.
Heat Maps : En metod för att uvärdera banor
Denna rapport har undersökt om game metrics genom heat maps kan användas för att hitta en choke point i en bana gjord till spelet Team Fortress 2. Game metrics och kvantitativa metoder erbjuder ett objektivt och nästan automatiserat alternativ till kvalitativa metoder när det kommer till balansering. En bana har konstruerats med en choke point och har speltestats för att generera en heat map. För att undersöka om det går att hitta en choke point med hjälp av en heat map så har en enkät gjorts där respondenter bads hitta choke pointen med hjälp av den heat mapen som genererades från speltestningen av banan. Alla respondenter lyckades hitta mitten av choke pointen med hjälp av heat mapen. I framtiden skulle arbetet kunna utökas genom att undersöka om användandet av bottar eventuellt skulle helt kunna automatisera balanseringsprocessen. Det skulle också gå att undersöka hur olika klasser rör sig i en bana..
Kirunametoden-Jämförelse emot en konventionell injusteringsmetod
AbstractWith increasing population and increasing demands for comfort and thus an increase in energy demand, it is necessary to examine various energy-efficiency measures. This work deals with the ability to control the flow through the heating system to achieve the desired comfort with as little energy as possibleA heating system contains of different parts, roughly speaking, you can divide it to three main components: Heat source, Distribution and Heat emitters. All components are working together to bring heat to the building. What is examined in this report are different ways of adjusting the flow and supply temperature and how it affects comfort and energy use in a building.At today ?s date the conventional method is to use a high flow through the heating system, which affects pressure drop and cooling of the fluid.
Utredning av solenergi för drivning av sorptiv kylprocess för inomhusluften på Stockholmsarenan
Cooling down the indoor air can be done in several ways. One way is desiccantcooling which will be used at the Stockholm Arena. This method is used in airhandling units that use temperature changes and moisture fluctuations in the air. Oneof the steps is to add heat during the cooling process in order to reduce the relativehumidity of the exhaust air. The air passes thru an adsorptions rotor which thenabsorbs moisture from the supply air.
Översyn av uppvärmning
The heating of companies premises is today functional with electrical heating and heating offossil fuel. The energy cost for these kinds of heating in buildings has heavily increased duringthe last years and the influence on the environment has become more visual. This leads to thatenterprises today become more anxious to render energy more effective and find alternativesolutions to their ancient heating systems. This is something that Skandinaviska kraftprodukterAB in Halmstad has become aware of.The purpose with this examination is to find the most cost-efficient and environmental measuresfor the office and workshop premises of SKP AB. Where one of the bigger things is to find agood alternative for their current oil furnace, which was heating the workshop.
Förluster i olika ensileringssystem
In Sweden the climate makes it impossible to feed fresh herbage to cattle during many months of the year. During periods when preserved forage must be supplied it is important that this forage is stored in such a way that high quality is retained, both nutritionally and hygienically.
Furthermore, it is essential that losses occurring when handling and storing the forage are kept as low as possible. This study compares storage in tower silos, bunker silos, big bags and bales,estimating dry matter losses as well as losses in metabolizable energy and crude protein that occur during storage. The results show that tower silos, bunker silos and big bags, the systems with the
largest amount of forage and a long feed out period involve larger losses than bales, which are fed out immediately after being opened. As the feed out rate influences the losses, tower silos and bunker silos should be used during the period of the year when the feed out rate is as high as
possible, i.e.
Termisk analys av kompakta jordvärmesystem - Sensitivitetsanalys och korrektions faktorer baserat på fältmätningar i referensanläggningar i Östergötland
Chapter 1 defines the aim of the project and gives a general orientation about ground heat extractors. In chapter 2 physical processes that could be expected to be involved in the heat transport around a ground heat exchanger are discussed. It is shown from a literature study what amount of moisture transport due to thermal gradients there could be expected in a ground heat exchanger. The conclusion is drawn that the moisture gradient (Sr) is of same magnitude as the driving temperature gradient (°C). At the expected amount of increased moisture around the pipes the moisture transport could be considered to have a little effect on the brine temperature.
Solmodul jord- och bergvärmepump
An increasing number of heat pump producers have developed heat pumps that can be connected to solar panels. In this thesis we have examined the possibilities of connecting solar panels to existing ground source- and geothermal heat pumps that has not been adapted to solar panels. During the work process, a prototype plant has been built to compare our theory with the practical results and with our designed sizing tool. The work has rendered in knowledge that will be used to build a sun module that can be easily connect to the existing heat pump system. The existing heat pump, our test plant, has been supplemented by an advanced storage tank used to allow different operating modes.
Potential för värmeåtervinning från mjölkkylanläggningar
The present climate discussion has made energy efficiency an interesting topic. Saving energy does
not only help the climate but also saves money for the energy consumer.
The purpose of this thesis was to examine the potential of heat recovering from milk cooling. Two
milk farms, one with voluntary milking system, VMS, and the other with conventional milking system
was used to measure interesting temperatures and electricity consumptions. The numbers were used
both to do theoretical calculations and to construct a SIMULINK model.
To calculate the potential for heat at milk farms theoretical calculations were made in MATLAB using
a reference farm with different combinations of heat recovery and pre cooling. The farm was
assumed to keep a dwelling house with the annual heat consumption 18165 kWh.
En kombinerad Organisk Rankinecykel och värmepump integrerat med ett fjärrvärmesystem : Där värme- och elproduktion samt lönsamhet studeras och avfall är huvudbränslet
The demand for district heating is expected to decrease in the future, due to competition from heat pumps and energy efficiency measures in buildings. Development of existing district heating systems is therefore necessary for district heating companies to maintain market shares. This Master?s thesis describes and investigates the heat and electricity production and profitability of a combined Organic Rankine Cycle (ORC) and heat pump that is integrated with an existing district heating system. The studied district heating system is utilizing heat from waste incineration. In Sweden waste constitute 20 % of the fuel mix used in district heating systems, and this share is expected to increase in the future.
Genetisk variation i brunststyrka hos svenska mjölkkor :
When cows in Sweden are inseminated the heat strength is reported to the Swedish milk-recording scheme and AI scheme. Cows that show strong signs of estrus are desirable and the trait is included in the Swedish breeding goal. A strong heat makes it easier to inseminate at the right time and to avoid long and expensive days open. Since ten years the heat strength is scored from one to five by the farmer and reported to the milk-recording scheme and AI scheme. Earlier the score was from one to three and the decision was made by the AI technician.
TCP/IP i taktiska ad hoc-nät
TCP (Transmission Control Protocol) is a transport protocol designed for the wired Internet. In wireless networks packet losses occur more frequently due to the unreliability of the physical link. The main problem is that TCP treats all losses as congestion, which leads to a lower throughput. Ad hoc networks are multihop wireless networks of mobile nodes, where each node can allow other packets to pass through it. Topology changes often occur and may lead to packet losses and delays, which TCP misinterprets as congestion.
Småskalig säsongslagring av solenergi för uppvärmning av bostäder : Simulering av lagerutformning och konsekvensen av adderade uppvärmningsbehov motsvarande en pool och ett atrium
The sun is a huge energy source with great potential of providing energy to the heating of homes and other buildings in an environmentally sustainable manner. In order to provide buildings with energy from the sun it is necessary to transfer the energy supply over time to when the demand arises. By storing the heat in a seasonal storage, solar energy from the summer can be used in the winter when the demand for heating is greatest.Today's existing plants are mainly in Europe and particularly in Germany. These facilities are designed to supply heat demands greater than 400 MWh and covers about 40-50 % of this need which consists of energy for space heating and domestic hot water. How much of the heat demand that is covered, the solar fraction, is partly due to losses from the storage which in turn is connected to the surface area of the storage.