Sök:

Sökresultat:

685 Uppsatser om Solar heat - Sida 17 av 46

Funktionell validering av mutation i PUS-1 i en patient med mitokondriell sjukdom

With the climate change issues growing in importance on the social agenda, the field of urban masterplanning is of no exception when it comes to minimizing the carbon footprint in a variety of projects. The aim of this thesis has been to prepare the Carbon Critical Masterplanning tool, a software plugin for carbon dioxide emissions assessment developed by Atkins, to be used in Swedish conditions. The main targets were to improve the areas of the tool associated with energy conversion and renewable energy sources, and to test the tool in a real case. A planned construction of a new campus in Albano, Stockholm was chosen for the pilot study. A 3D model was built in the tool and the carbon footprint was calculated for a variety of combinations for energy supply to the future area.

Biogas till kraftvärme på Wapnö : en projektanalys utifrån ett företagsekonomiskt perspektiv

Biogas is a gaseous fuel, rich in methane, produced through a biological route in an anaerobic digester. A gas engine generates combined heat and power, which can be used at the farm to reduce energy cost. The process also generates a digestate, with better utilization of nutrient compared to cattle manure. The aim of this study is to analyze the profitability of a farm-scale biogas plant for combined heat and power (CHP) at Wapnö. Wapnö is an agriculture company located in the southern part of Sweden.

Stadsklimat/Gatuklimat :

The purpose of this paper is to understand the climate of the street and how it can be modified to better meet the needs of the street and the user groups. At the same time the conditions of the street and its surroundings also has to be taken into account. To accomplish this it is necessary to have a broad knowledge of the climate conditions in the city. Therefore an overview of the climate elements and how these are modified in the built-up areas are given. The part of the paper which deals with the city climate has a global approach to be able to give an as complete picture as possible.

Värmeväxlare med luftkonditionering för tvättstugor

The energy in laundry rooms, in form heated air, can be utilized with a heat exchanger. A concept and an early prototype of the heat exchanger have already been developed to show that the theory works. This report describes the continued development and construction of the product.A field study was made in order to investigate the environmental usage and establish the product design. The most common washing machine was used as a calculation model, and calculations were also made to estimate the amount of energy in the air. A previous analysis of the existing prototype is also presented in this report, to show the products potential capacity.

Utvärdering av miljönytta för olika miljöcertifieringssystem för byggnader : En jämförande fallstudie på Swecos kontor i Stockholm, Göteborg och Malmö

This thesis examines the environmental benefits resulting from the choice of environmental certification scheme, with focus on energy. This was carried out by studying the measures that were implemented as a result of the certification of Sweco's three largest office buildings in Stockholm, Gothenburg and Malmö. The office property in Stockholm has been certified with the Swedish Environmental Building, Gothenburg with the British BREEAM and Malmö with the U.S system LEED.The results from the study indicate that an environmental certification can reduce the energy consumption by up to 59 percent and the water consumption by 20 to 66 percent. However; the interviews, literature study and simulations in MATLAB indicate that the size and scope of these environmental benefits depend on several identified factors: the type of building and its conditions, system selection, grade level, the choice of indicators, the ambition of those involved and when in time the certification process begins. The comparison between Environmental Building, LEED and BREEAM showed that Environmental Building for the office property in Stockholm gave the largest environmental benefit in terms of reduced energy consumption thanks to several large measures.

Effektiviseringsåtgärder i tryckluftsystemet hos Vattenfall Värme Uppsala

In this work an assessment of the compressed air system in the facilities of Vattenfall Heat Uppsala has been conducted. The facilities constitutes, among others, a combined heat and power plant, and two waste incineration plants. The compressed air is supplied primarily by seven rotary screw compressors and yearly electric energy consumption in these has been determined. Furthermore, the usage of compressed air has been mapped in order to find processes with energy savings potential. Several suggestions how to reduce the usage of compressed air have been presented, resulting in decreased need of electric energy and reduced CO2-emissions.The results show that total need of electric energy in the compressors, during a standard production year, amounts to 5.83 GWh.

Utvärdering av AOT för ett pilotskaligt, recikulerat akvakultursystem för fiskodling

With the climate change issues growing in importance on the social agenda, the field of urban masterplanning is of no exception when it comes to minimizing the carbon footprint in a variety of projects. The aim of this thesis has been to prepare the Carbon Critical Masterplanning tool, a software plugin for carbon dioxide emissions assessment developed by Atkins, to be used in Swedish conditions. The main targets were to improve the areas of the tool associated with energy conversion and renewable energy sources, and to test the tool in a real case. A planned construction of a new campus in Albano, Stockholm was chosen for the pilot study. A 3D model was built in the tool and the carbon footprint was calculated for a variety of combinations for energy supply to the future area.

Carbon Critical Masterplanning tool : klimatpåverkan från samhällsplaneringsprojekt

With the climate change issues growing in importance on the social agenda, the field of urban masterplanning is of no exception when it comes to minimizing the carbon footprint in a variety of projects. The aim of this thesis has been to prepare the Carbon Critical Masterplanning tool, a software plugin for carbon dioxide emissions assessment developed by Atkins, to be used in Swedish conditions. The main targets were to improve the areas of the tool associated with energy conversion and renewable energy sources, and to test the tool in a real case. A planned construction of a new campus in Albano, Stockholm was chosen for the pilot study. A 3D model was built in the tool and the carbon footprint was calculated for a variety of combinations for energy supply to the future area. The results show that use of locally installed renewable energy sources can reduce the total climate impact when life cycle perspective is applied.

Are changes in heart rate and/or arborisation of vaginal mucus useful parameters for detecting heat in heifers? :

The milk production per cow has increased considerably during the last 50 years and due to the breeding for higher milk production also brings decreased reproduction efficiency. In a Swedish study 1996 it was shown that on average only half of all estruses were detected. Every time a farmer fails to detect oestrus it costs the farmer about 1200 Swedish crones and the need of means of detecting oestrus is therofore large. With this study we wanted to investigate if heart rate respectively crystallisation of vaginal mucus (arborisation) could be useful means of detecting oestrus. We monitored two oestrus cycles in four heifers.

Carbon Critical Masterplanning tool : klimatpa?verkan fra?n samha?llsplaneringsprojekt

With the climate change issues growing in importance on the social agenda, the field of urban masterplanning is of no exception when it comes to minimizing the carbon footprint in a variety of projects. The aim of this thesis has been to prepare the Carbon Critical Masterplanning tool, a software plugin for carbon dioxide emissions assessment developed by Atkins, to be used in Swedish conditions. The main targets were to improve the areas of the tool associated with energy conversion and renewable energy sources, and to test the tool in a real case. A planned construction of a new campus in Albano, Stockholm was chosen for the pilot study. A 3D model was built in the tool and the carbon footprint was calculated for a variety of combinations for energy supply to the future area.

Energianalys av hygieniseringssystem : jämförelse av befintlig pastörisering med integrerad termofil hygienisering på Kungsängens gårds biogasanläggning i Uppsala

The biogas plant Kungsängens gård, owned by Uppsala Vatten och Avfall AB, produces biogas and biomanure from organic household waste, food processing waste and slaughterhouse waste. In year 2012, 4.4 million Nm3 of biogas were produced from 25 200 tons of waste. Before digestion all substrate is sanitized by pasteurization at 70°C in order to kill pathogens. Another method, integrated thermophilic sanitation (ITS), is of interest in order to decrease the energy demand. The method implies that the substrate is sanitized during ten hours in the digestion chamber, where the temperature is 52°C.

Energieffektivisering i ett verkstadsföretag : En analys av energibesparande åtgärder samt uppvärmnings- och kylsystems driftkostnader och koldioxidutsläpp

The energy use in a workshop company has been examined in this work in order to find areas for energy efficiency improvement. The combined oil and electricity heating in the company were compared with other alternative heating systems including cooling of the premises in following combinations:Ground source heat pump for heating and coolingDistrict heating and absorption coolingDistrict heating and low temperate surface water coolingEnergy use, operation costs and carbon dioxide emissions were calculated for the current heating systems and the three alternatives including cooling. The ground source heat pump for heating and cooling decreases bought energy with 34 MWh annually compared to current heating only. The district heating and low temperate surface water cooling has the largest reduction of operation cost and carbon dioxide. The operation cost decreases with 42 kSEK and the carbon dioxide with 43 metric ton CO2 annually.

Energianvändning för markkonstruktioner förlagda med ytvärme : En teknisk och ekonomisk utredning av fördelarna med att isolera under värmerören

The need for snow-free surfaces at squares, bus stops, platforms, car parks and sports facilities increases and at the same time energy price rise and the environment is becoming a hotter issue. The construction of the ground heating systems often lack thermal insulation under the heating pipes, which means that the heat from the pipes not only warm up the soil surface but also heats the surrounding soil. The insulation also has more features, by insulating the risk of frost damage is minimized. The goal of this report is to demonstrate the large heat loss and energy costs in the absence of insulation under the heating system.The report begins with a scientific way to study and treating the soil heating system uses, and the theory involved. Furthermore it also deals with different routing principles of heat pipes depending on the facility.All calculations are made with so called finite element method (FEM), in COMSOL Multiphysics 3,5a, where models are created with different conditions.

Funktionsupphandling av solelanläggningar

This thesis aims to contribute to improved functional procurement of photovoltaic systems, PV systems. Functional procurement means that criteria concerning a function are set rather than specifying technical details or products. Possible advantages and difficulties in using functional procurement have been analyzed by interviews, simulations and a case study. Electricity production and surplus production for different scenarios have been simulated via MATLAB. The MATLAB script was also used to generate rules of thumb on feasible solar fraction for six different load profiles; a church, a farm, a car mechanic, an office, an industry and an apartment building.

Passivhus, detaljutformning och dess köldbryggor

Along with rising energy prices and increasing awareness of environmental issues, the criteria for buildings energy performance have been sharpened through the years. Today, ?passive house? and ?low energy house? are commonly used phrases in the construction industry and is expected to become increasingly common in the future.For houses with well-insulated building envelope the importance of well constructed details increases when minimizing the heat losses. Examples of these details are floor-wall junction and window openings in the wall. In such connections thermal bridges occur, which means that heat more easily is transported out of the building, compared to the rest of the building envelope.This report deals with detail solutions around windows and a comparison between a traditional slab and a foundation from Koljern consisting of foam glass.

<- Föregående sida 17 Nästa sida ->