Sökresultat:
191 Uppsatser om Sewage sludge - Sida 3 av 13
Vattenkemin i Fyrisån under snösmältningen
Chemical substances are spread diffusely and uncontrollably as a result of the increased consumption of goods. REVAQ is a certification system that works to reduce the flow of hazardous substances to Swedish treatment plants and to create a sustainable nutrient recycling. According to REVAQ, the yearly accumulating rate of metals should not exceed 0.2% in soil per year. Silver and bismuth are two metals that do not fulfill this requirement. The silver concentration in sludge decreased during the last decade, however the last few years, it has leveled off.
Käppalaverkets nuvarande och framtida rötningskapacitet : en studie i labskala
Käppala wastewater treatment plant situated on the island of Lidingö northeast of Stockholm is running a project during 2004 and 2005 with the purpose to map out the capacity of anaerobic digestion in the digesters that treat primary and excess sludge. The purpose of this thesis work, which is part of that project, was to characterize the present anaerobic digestion process and to investigate its capacity to treat other organic wastes such as restaurant waste and waste from water works. To decide the potential of both methane and biogas production from different substrates batch laboratory tests were carried out. To imitate the anaerobic digestion process at Käppala continuous tests with small scale reactors were carried out. These reactors were later fed with restaurant waste.The batch laboratory tests showed that primary sludge had a potential biogas and methane production of 0,62 and 0,35 Ndm3/g VS respectively after 40 days of digestion.
Optimering av biologisk fosfor och kvävereduktion i ett reningsverk för hushållsspillvatten
In connection with Henriksdals wastewater treatment plant (WWTP) a smaller plant is situated called Sjöstadsverket where new methods for wastewater treatment are tested and evaluated in different process lines. On one of the lines experiments with enhanced biological phosphorous removal (EBPR), have been carried out to evaluate if it is a good alternative to traditional chemical phosphorus removal. This thesis evaluates the results from the experiments conducted during fall 2005.The incoming water from Hammarby Sjöstad consists of only household wastewater, which gives a wastewater with high concentrations of nutrients and organic carbon. This is partly positive, because one of the limiting factors for effective biological phosphorus removal is the lack of easily biodegradable organic carbon. The high concentrations of ammonium and phosphorus demand a high reduction to achieve the requirements of outgoing concentration.To optimize the process experiments with different recirculations and different aeration techniques have been made.
Silver och vismut i plaster och färger : Källor till förhöjda halter i slam?
Chemical substances are spread diffusely and uncontrollably as a result of the increased consumption of goods. REVAQ is a certification system that works to reduce the flow of hazardous substances to Swedish treatment plants and to create a sustainable nutrient recycling. According to REVAQ, the yearly accumulating rate of metals should not exceed 0.2% in soil per year. Silver and bismuth are two metals that do not fulfill this requirement. The silver concentration in sludge decreased during the last decade, however the last few years, it has leveled off.
Miljösystemanalys av alternativa avloppssystem i ett urbant område ?Svartvattensystem : Skogaberg ? Ett pilotprojekt i Göteborg
Starting point to this Paper is the idea and wish to adapt the society and its different activities to a recycle society. A building area in Göteborg is planned and investigated for such adaptation. In the district named Skogaberg, about 130 households totally are planned from what 20 are blocks of flats. The idea with this project is to constitute an alternative sewage system, a Blackwater system, were the fractions of most nutrients and least pollution are separated, taken care of and utilised. The aim is to get a market and use the nutrients of the organic waste from the household in agriculture use.
Skillnader i vatten- och avloppshantering inom EU : En jämförelse mellan Slovakien och Sverige
The management of water resources and waste water varies between the countries of the EU. For many years, a large part of the water in Europe has been contaminated by, among other things, insufficiently treated waste water and emissions from agriculture. The EU Water Framework Directive 2000/60/EC and the Urban Waste Water Directive 91/271/EEC are intended to harmonize fresh-water management and waste water management within the whole EU, aiming at safeguarding drinking water of good quality and a high quality of all water within the EU today and in the future. There are however some problems concerning the waste-water directive. One problem is the huge investment needed in Slovakia to fulfil the demands of the waste-water directive for waste-water management in larger communities (with more than 2000 inhabitants).
Källsorterade systems påverkan på avloppsreningsverk : växthusgaser, energi- och resursanvändning i modellstudie
The aim of this study was to evaluate the effects on a simulated wastewater plant regarding GHG emissions and use of energy and resources when implementing source separated wastewater systems. The effects were studied for different restrictions of effluent quality and for different temperatures on the influent. The simulation model BSM2G calibrated for Käppala wastewater treatment plant was used. The task was executed by simulating nine different scenarios with an increase in influent load from new connections equivalent to 3, 10 and 30 % of the present connections. These new connections were served by conventional, urine separated or black water separated systems.
Occurrence of Verotoxin-encoding phages in mussels grown downstream the sewage treatment plant in Lysekil
The purpose of this study was to investigate the occurrence of Verotoxin-encoding bacteriophages in mussels, cultured downstream the sewage treatment plant in Lysekil.Mussels were collected in three growing areas from April 2008 to March 2009. Real-time PCR was performed for detection of vtx1 and vtx2 genes and enrichment of bacteriophages on non Verotoxin-producing Escherichia coli O157: H7 was carried out. All samples in real-time PCR analysis were negative; no presence of Verotoxin-encoding phages was shown. No plaque was formed on blood agar base plates, indicating that no bacteriophages had been taken up by E. coli bacteriaThe levels of Verotoxin-encoding phages and E.coli outside the sewage treatment plant in Lysekil were not high enough to be able to form VTEC in mussels, indicating that the faecal contamination was low.
Spårning av miljöstörande ämnen i Uppsala stads spillvattennät
To the sewer systems households, industries and other activities are connected. The wastewater is collected at treatment plants where a nutritious sludge is produced. The sludge does not only contain nutrients, but also hazardous substances originating from different activities in society. To reduce the flow of hazardous substances to treatment plants and to create a sustainable recycling of plant nutrients the Swedish Water & Wastewater Association has developed the certificate system REVAQ. This certificate requires a good quality of the sludge but also that the treatment plants maps the origin of the unwanted substances.
LTA kontra självfall : Ett långsiktigt perspektiv
Detta arbete syftar till att göra en utvärdering av hur de två skilda spillvattensystemen LTA (Lätt TryckAvlopp) och konventionellt självfallsavlopp står sig mot varandra ur ett långtidsperspektiv. Aspekter så som investering, drift, underhåll, miljöpåverkan, teknik och anläggning har analyserats och sammanställs av denna rapport, samt ett program som beräknar den ekonomiska aspekten mellan respektive system. Programmet, där användaren ges möjligheten att specificera sitt eget område, ger en fingervisning om den lösning som ur ekonomisk aspekt är mest fördelaktig. Detta kombinerat med den kunskap som samlats i rapporten ska leda till ett mer medvetet val hos kommuner och andra VA-huvudmän i Sverige..
Geokemisk undersökning vid Rävlidmyrgruvan, Västerbottens län : provtagning, analys och förslag till åtgärder
The mining industry, in terms of ore excavation and metal production, is and has been
important to the Swedish economy. In connection with the ore excavation process, large
amounts of partly sulphidic waste are produced. When the metal sulphides are exposed to air and water they are eventually oxidised, which leads to the formation of acidic water with high concentrations of metal cations and sulphate ions, so called Acid Mine Drainage
(AMD). This water may reach the nearest surroundings and cause negative environmental
effects. By covering the waste with soil or water, the oxidation process can be minimised.
At the Rävlidmyran mine in the county of Västerbotten open pit mining took place between
1951 and 1991.
Förbehandlingstekniker och LCA för rötning av organiskt avfall : Modellkonstruktion och Utvärdering med ORWARE
The goal of this master thesis project was to develop computer models of some plausiblepretreatment techniques and to assess the potential benefits/costs of using pretreatment andanaerobic digestion for waste management of organic waste from a system perspective. Forthis purpose a computer program called ORWARE has been used. ORWARE (organic wasteresearch) is a program for making life cycle assessments of waste management. As the mainpart of the project work the ORWARE system has been provided with three new models ofpretreatment techniques. The additions consist of: One model of pretreatment with ultrasound,one model of thermal hydrolysis and one model of a screw press.
Hydrolys av primärslam för förbättrande av biologisk fosforreduktion vid behandling av hushållsavloppsvatten [Hydrolysis of primary sludge for enhancement of biological phosphorus removal in household wastewater]
Hammarby Sjöstad is a new district of southern Stockholm built with focus on reduced environmental impact by recirculation of materials and sustainability. The environmental goals aim to cut the water consumption by half and a separate storm water treatment. Thus, the wastewater will be more concentrated and will originate from the households only. The Sjöstad project includes the idea of a local treatment plant for the household wastewater. To evaluate this possibility, Sjöstadsverket, an experimental treatment plant was constructed.
Beräkningsmodell för massbalanser för Slottshagens reningsverk
In the next few years the pollutants loading at the Slottshagen wastewater treatment plant in Norrköping is going to increase due to the reason that one of the waste water treatment plant in the district will be shut down.A survey of how these different pollutants are divided in the treatment process is therefore necessary for mapping out both the loading and treatment efficiency.This can be achieved by studying mass balances.Mass balances were carried out for the water treatment process for the mechanical/chemical,biological and the chemical stage.The mass balance studies show that the treatment efficiency was very good. However in order for the mass balances to be quite consistent and to ensure complete coverage of results and conclusions i.e. more reliable results, sludge samples should be collected and taken at different times per day and the influent rate should be investigated.In this work mass balance has been set up in order to illustrate and identify the factors that should be considered and taken care of for further estimation using mass balances in the future. Furthermore this survey results in a calculating model for the mass balances at thisplant.This calculating model is used as a tool to facilitate future calculations for mass balances for the water treatment process at Slottshagens wastewater treatment plant.Moreover it provides a basis for carrying out further estimation of the treatment process in the near future.In this project the importance of some operating parameters was also taken in consideration.This calculating model can be modified so that calculations of such operating parameters i.e. sludge loading and sludge age can be easily performed.Such information can be used further to evaluate different operation alternative in order to ensure an optimal use of the treatment process with in the plant..
Utvärdering av avloppsvattenreningen vid Hallsta Pappersbruk : Kartläggning av inkommande avloppsvatten och optimering av driftparametrar
Hallsta paper mill uses large amounts of water during the pulp and paper making processes. The wastewater is treated in two separate activated sludge processes referred to as BIO 1 and BIO 2. The main aim is to reduce the organic substance content, measured as COD (Chemical Oxygen Demand) before the wastewater is released into the environment. Since the effluent produced is very rich in organic substances, the addition of nitrogen (N) and phosphorus (P) are necessary to give satisfactory treatment results. Problems with sludge bulking sometimes occur which lead to increased levels of suspended matter and nutrients in the effluent.