Sök:

Sökresultat:

608 Uppsatser om Rotating heat exchanger - Sida 4 av 41

Geotermisk fjärrvärme i Gunsta

Gunsta is situated about 10 km east of Uppsala. Today there are plans to establish 1000 new households in Gunsta before year 2030. The required energy for heating houses and water would be distributed via a district heating system, which also includes 200 existing residences. The annual required energy, according to this study, would be 16.2 GWh with a maximal peak effect of 6.9 MW. To meet this need, the study suggests a system with heat pumps to upgrade the 31?C water from a 1.8 kilometre deep borehole.

Spillvärmeåtervinning ur kylvattensystemet ismältverket på Sapa Profiler AB i Sjunnen

The smelting process at Sapa Profiler AB in Sjunnen generates large quantities of waste heat which is absorbed by the cooling water when the aluminum is cooled down. This paper is the result of a Master?s Degree Project aiming to present the conditions for recycling the waste heat. The cooling water absorbs the heat from the aluminum at an average rate of 600 kW and the paper shows that it can be used to replace electrical power consumption for heating the production plant?s facilities.

Heat Maps : En metod för att uvärdera banor

Denna rapport har undersökt om game metrics genom heat maps kan användas för att hitta en choke point i en bana gjord till spelet Team Fortress 2. Game metrics och kvantitativa  metoder  erbjuder  ett  objektivt  och  nästan  automatiserat  alternativ  till kvalitativa metoder när det kommer till balansering. En bana har konstruerats med en choke point och har speltestats för att generera en heat map. För att undersöka om det går att hitta en choke point med hjälp av en heat map så har en enkät gjorts där respondenter   bads   hitta   choke   pointen   med   hjälp   av   den   heat   mapen   som genererades från speltestningen av banan. Alla respondenter lyckades hitta mitten av choke  pointen  med  hjälp  av  heat  mapen.  I  framtiden  skulle  arbetet  kunna  utökas genom  att  undersöka  om  användandet  av  bottar  eventuellt  skulle  helt  kunna automatisera  balanseringsprocessen.  Det  skulle  också  gå  att  undersöka  hur  olika klasser rör sig i en bana..

Högtempererat borrhålslager för fjärrvärme

The district heating load is seasonally dependent, with a low load during periods of high ambient temperature. Thermal energy storage (TES) has the potential to shift heating loads from winter to summer, thus reducing cost and environmental impact of District Heat production. In this study, a concept of high temperature borehole thermal energy storage (HT-BTES) together with a pellet heating plant for temperature boost, is presented and evaluated by its technical limitations, its ability to supply heat, its function within the district heating system, as well as its environmental impact and economic viability in Gothenburg, Sweden, a city with access to high quantities of waste heat.The concept has proven potentially environmentally friendly and potentially profitable if its design is balanced to achieve a good enough supply temperature from the HT-BTES. The size of the heat storage, the distance between boreholes and low borehole thermal resistance are key parameters to achieve high temperature. Profitability increases if a location with lower temperature demand, as well as risk of future shortage of supply, can be met.

Solmodul jord- och bergvärmepump

An increasing number of heat pump producers have developed heat pumps that can be connected to solar panels. In this thesis we have examined the possibilities of connecting solar panels to existing ground source- and geothermal heat pumps that has not been adapted to solar panels. During the work process, a prototype plant has been built to compare our theory with the practical results and with our designed sizing tool. The work has rendered in knowledge that will be used to build a sun module that can be easily connect to the existing heat pump system. The existing heat pump, our test plant, has been supplemented by an advanced storage tank used to allow different operating modes.

Potential för värmeåtervinning från mjölkkylanläggningar

The present climate discussion has made energy efficiency an interesting topic. Saving energy does not only help the climate but also saves money for the energy consumer. The purpose of this thesis was to examine the potential of heat recovering from milk cooling. Two milk farms, one with voluntary milking system, VMS, and the other with conventional milking system was used to measure interesting temperatures and electricity consumptions. The numbers were used both to do theoretical calculations and to construct a SIMULINK model. To calculate the potential for heat at milk farms theoretical calculations were made in MATLAB using a reference farm with different combinations of heat recovery and pre cooling. The farm was assumed to keep a dwelling house with the annual heat consumption 18165 kWh.

Energieffektiviserande åtgärder i samband med renovering av flerbostadshus

In Sweden, a big part of the energy use is used in the housing sector. Political goals and targets are set up which the housing sector needs to work towards. Apartment buildings are a major part of the housing sector in Sweden and therefore reduction of energy use in these kinds of buildings are key to lower the energy use in Sweden. But there are not only political incentives to reduce the energy use. Some energy?saving measures are directly profitable and should thus be performed.

En kombinerad Organisk Rankinecykel och värmepump integrerat med ett fjärrvärmesystem : Där värme- och elproduktion samt lönsamhet studeras och avfall är huvudbränslet

The demand for district heating is expected to decrease in the future, due to competition from heat pumps and energy efficiency measures in buildings. Development of existing district heating systems is therefore necessary for district heating companies to maintain market shares. This Master?s thesis describes and investigates the heat and electricity production and profitability of a combined Organic Rankine Cycle (ORC) and heat pump that is integrated with an existing district heating system. The studied district heating system is utilizing heat from waste incineration. In Sweden waste constitute 20 % of the fuel mix used in district heating systems, and this share is expected to increase in the future.

Genetisk variation i brunststyrka hos svenska mjölkkor :

When cows in Sweden are inseminated the heat strength is reported to the Swedish milk-recording scheme and AI scheme. Cows that show strong signs of estrus are desirable and the trait is included in the Swedish breeding goal. A strong heat makes it easier to inseminate at the right time and to avoid long and expensive days open. Since ten years the heat strength is scored from one to five by the farmer and reported to the milk-recording scheme and AI scheme. Earlier the score was from one to three and the decision was made by the AI technician.

Energianalys av hygieniseringssystem : jämförelse av befintlig pastörisering med integrerad termofil hygienisering på Kungsängens gårds biogasanläggning i Uppsala

The biogas plant Kungsängens gård, owned by Uppsala Vatten och Avfall AB, produces biogas and biomanure from organic household waste, food processing waste and slaughterhouse waste. In year 2012, 4.4 million Nm3 of biogas were produced from 25 200 tons of waste. Before digestion all substrate is sanitized by pasteurization at 70°C in order to kill pathogens. Another method, integrated thermophilic sanitation (ITS), is of interest in order to decrease the energy demand. The method implies that the substrate is sanitized during ten hours in the digestion chamber, where the temperature is 52°C.

Energianalys av hygieniseringssystem : jämförelse av befintlig pastörisering med integrerad termofil hygienisering på Kungsängens gårds biogasanläggning i Uppsala

The biogas plant Kungsängens gård, owned by Uppsala Vatten och Avfall AB, produces biogas and biomanure from organic household waste, food processing waste and slaughterhouse waste. In year 2012, 4.4 million Nm3 of biogas were produced from 25 200 tons of waste. Before digestion all substrate is sanitized by one hour?s pasteurization at 70°C in order to kill pathogens. Another method, integrated thermophilic sanitation (ITS), is of interest in order to decrease the energy demand.

En studie av Uppsala stads värmeö

The urban heat island is an area restricted to a city center where the temperatureis higher than its surrounding environment. The greatest temperature difference isfound at night when the weather is calm and the sky is clear of clouds. There are twomajor causes behind this phenomena and the first one is the use of energy forheating of houses. The heat leaks through the walls of the buildings and warms upthe surrounding mass of air. The second one is the use of building material whichstore the suns radiation on daytime and releases the heat during night.

Utveckling av kyl- och smörjsystem för ekobilen Agilis HCCI motor

Every year, KTH participates in the Shell Eco Marathon, a competition whose goal is to design a vehicle that can go as far as possible using only the equivalent energy of one liter of petrol fuel. This year, one of KTH?s contributions to this race is the Agilis prototype; a car powered by a uniquely configured HCCI-engine developed at the university. The engine is dependent of several subsystems in order to work properly, among other, systems for cooling and lubrication.Combustion engines are in need of a cooling system that reduces the heat developed during the combustion. In general, two main types of cooling systems are employed; either air cooling, where the outside of the cylinder is exposed to a flow of the surrounding air, ore water cooling, where water flows in tubes around the engine, and the heat are transferred by the water to the surrounding air through a heat exchanger.The purpose of the lubrication system is to prevent the friction that builds up in the interference between moving parts in the engine.

Skalkonstruktion : Med inriktning mot hållfasthet och dämpning av ljud

The sound part is mainly practical and is dependent on concepts that have been tested through measuring with a sound level meter. The design part is more theoretical and has been verified with CAD models and finite element analysis.With a sound damping hood on the compressor the sound level is reduced with up to four dB. An optimized absorbent for the compressor space gives a reduction with three dB. By using the insulation for the heat water tank as absorbent we can see a sound reduction on the lover octave bands. A reduction like this is elsewhere hard to achieve as at it requires thick absorbents.By changing the today?s insulation to the heat water tank to a form of polystyrene polymer insulation the weight from the heat pump above can be transferred to the stable heat water tank.

Integrering av pelletsfabrik med Rya kraftvärmeverk i Göteborg : en teknisk och ekonomisk utredning

Göteborg Energi has a surplus of district heating during spring, summer and fall. The heat surplus is due to a constant production of waste heat from oil refineries and heat from waste incineration over the year. It would be desirable to increase the demand for heat and the uptime for the newly built combined heat and power generation plant, Rya Kraftvärmeverk. One alternative could be to integrate Rya Kraftvärmeverk with a pellet production facility. By producing heat, electricity and pellet in a joint process the energy use can be decreased.

<- Föregående sida 4 Nästa sida ->