Sökresultat:
176 Uppsatser om Moisture - Sida 6 av 12
Energi- och kostnadseffektiva klimatskal : För lager-, industri- och kontorsbyggnader
A study to optimize insulation thickness for stock-, industrial- and office-buildings for external walls and roof in an economical perspective has been conducted on behalf of DynaMate. DynaMate?s role is to maintain all Scania?s buildings. Analysis has also included other parts of the building envelope, such as windows, exterior doors and industrial doors. In this thesis, three different types of exterior wall constructions has been investigated, these are a sandwich design consisting of sheet metal and a another one consisting of concrete, as well as a wall of concrete with a coating of plasters.
Utredning av solenergi för drivning av sorptiv kylprocess för inomhusluften på Stockholmsarenan
Cooling down the indoor air can be done in several ways. One way is desiccantcooling which will be used at the Stockholm Arena. This method is used in airhandling units that use temperature changes and Moisture fluctuations in the air. Oneof the steps is to add heat during the cooling process in order to reduce the relativehumidity of the exhaust air. The air passes thru an adsorptions rotor which thenabsorbs Moisture from the supply air.
Att bygga i trä eller lättbetong : en jämförelse mellan väggkonstruktioner
Hudiksvall Municipality will build a new preschool. The goal is that the pre-school should reflect the municipality's environmental goals and meet building regulations. The wall structures that are compared in the report is an insulated wooden frame and a frame of lightweight concrete blocks from H + HWall structures are compared within the areas of U-values, air tightness, thermal storage capacity, fire ratings, Moisture, durability, emissions and environment. In these categories the two wall structures will be rated in a scale from 1 to 5 and then the categories are weighted against each other. The weighting is based on Hudiksvall Municipality's assessment of the categories importanse for their final selection.The results of the comparison show that the concrete structure is recommended for the construction of pre-school with 27.55 points against the wooden structures 23.70 points.
Industrialiserat byggande : Fältfabrikens användning, utveckling och framtid
The construction industry is currently receiving much criticism for inefficiency and slow development while demands for reduced built in Moisture and efficiency increases. This report examines whether the use of field factories can meet these requirements and what factors that will be critical for future use of field factories. Industrialized construction with field factory is compared with traditional loose timber construction and industrial construction in the fields of execution, logistics and working environment. The aim of this report is to provide a basis for field factories current and future use and development. To achieve the aim of the report, people with experience in the use of the various methods was interviewed and literature studies in the various fields done.
Utfackningsvägg av lättbetongblock i passivhus
AbstractThis report intends through a case study to investigate if lightweight concrete isappropriate as main material in the outer wall of a seven storey residential building.A technical design is carried out in accordance with the definitions and requirementsfor passive houses, given by FEBY?s1 ?Demand specification for passive houses?.A literature review is also carried out for a comparison between regular bolt wall andlight weight concrete wall, with a focus on the safety of Moisture.The lightweight concrete block used in the report is as a celblock produced by thecompany H+H Sweden AB.The methods used have resulted in compliance with requirements andrecommendations from authorities. Calculations of energy, noise and Moisture riskassessment has been carried out.The work has resulted in the conclusion that the lightweight concrete itself is notable to isolate in the extent necessary to obtain chosen U-value of 0,1 W/m2 ° C,without getting to thick. Therefore additional insulation is needed. There are fewrelevant reference objects built with only light weight concrete.
Upplevd trafiksäkerhet med mittbarriär
AbstractThis report intends through a case study to investigate if lightweight concrete isappropriate as main material in the outer wall of a seven storey residential building.A technical design is carried out in accordance with the definitions and requirementsfor passive houses, given by FEBY?s1 ?Demand specification for passive houses?.A literature review is also carried out for a comparison between regular bolt wall andlight weight concrete wall, with a focus on the safety of Moisture.The lightweight concrete block used in the report is as a celblock produced by thecompany H+H Sweden AB.The methods used have resulted in compliance with requirements andrecommendations from authorities. Calculations of energy, noise and Moisture riskassessment has been carried out.The work has resulted in the conclusion that the lightweight concrete itself is notable to isolate in the extent necessary to obtain chosen U-value of 0,1 W/m2 ° C,without getting to thick. Therefore additional insulation is needed. There are fewrelevant reference objects built with only light weight concrete.
Smarta Hus : Nya behov och lösningar med participativ design
In this Bachelor Thesis (20 p.), we present the history and development of "Intelligent Houses", and most important- explore some of the future possibilities in this area. The project has been carried out through an interdisciplinary cooperation between three different educations at the Blekinge Institute of Technology. By conducting a dialogue with various actors with different professions, we have been trying to identify needs within the concept of "Intelligent Houses", were the end user is not only the tenant or homeowner. Through Participatory Design methods, such as a Future Workshop, we have brought the users together to discuss their own and each others needs and hindrances in their respective work practice, and how intelligent house technology could improve their work conditions. We have also been testing a highly sophisticated CO/CO2/Moisture/Temperature/Enthalpy multi-sensor & controller, originally developed for regulating indoor climate systems.
Effects of storage time, die channel length and moisture content on pellet quality of lodgepole pine (Pinus contorta Dougl. var. latifolia)
The use of renewable resources is rapidly increasing in Sweden, especially the use of fuel pellets. Through pelletizing the energy content per volume unit is greatly increased and the pellets are more homogeneous with regard to Moisture content, particle size and density compared to unrefined fuels like forest residues and chips. For further development of the Swedish pellet industry, the use of different assortments from lodgepole pine (Pinus contorta Dougl. var. latifolia) is of particular interest, mainly because of its high volume production.
Försäkringsbolags kostnader för reparation av fuktskadade badrum
The purpose of this report is to compile and examine the cost of renovation of Moisture-damaged bathrooms, to derive a target price. The target price can then be used by insurance companies to estimate the ultimate cost of future bathroom renovations. The method is based on the compilation and comparison of the cost of repairs of previous water damage in bathrooms. The calculations compiled based on repair estimates for different insurance losses from one of the leading insurance companies in Sweden. The result shows the average price per square meter of floor area for different sizes of bathrooms. The average price is the basis for the estimate of future renovation costs of bathrooms. The results further show that the bathroom finishes, area and the distance between the entrepreneur and the location of the renovation have great impact on the final repairing cost.
Passivhus med prefabelement : En jämförelse mellan en platstillverkad konstruktion och prefabelement från Masonite Lättelement AB
This thesis conducted at the University of Uppsala investigateshow well a prefabricated building component from the manufacturerMasonite Lättelement AB can be incorporated into ahouse projected to accomplish the demanding criteria of a passivehouse. The thesis is organized as a comparison betweenthe prefabricated elements and an on-site built component fromthe passive house area of Oxtorget in Värnamo, Sweden. Theaspects investigated were air leakage, energy, Moisture, economyand noise conditions.Results of the comparative analyzes shows that the prefabricatedproducts were capable of accomplishing the requirementsof passive houses and therefore this thesis should beviewed as a basis to confirm that the technology of prefabricatedbuilding components today in Sweden are mature enoughto be a significant part of the passive houses that are to be builtin the near future. The development of prefabricated technologyis of crucial significance if we are to accomplish the goalsof reduced energy consumption by the year 2020..
Veingeskolan F - Undersökning av inomhusmiljön samt en konstruktionsmässig utvärdering
Title: Veingeskolan F - Investigation of the indoor environment and a structural analysisMethod: Complete analysis of structural drawings to determine if the school have been constructed correctly. In my teorethical studies of the drawings I must seek out points that may have been damaged from Moisture, this contains a full survey of the foundation, walls and ceiling. To strenghten the data collected from the drawings I must visit the school and do field investigations to find out if the school has any problems with the indoor environment.Analysis: I determined that we had some damages on specific places, these damages was caused by leaking roofs, a carpet that was tarnished by strong sunlight in connection with some type of glue and also the ventilation that may have been drawing malodorous air from a shaft in the foundation.Conclusion: I was able to see that the decision to demolish the school was quite drastic, if the county would have done continuous fixups on the construcion when the employes had complained maybe the action to the tear the school down would have been unnecessary. The lack of communication between the two parts lead up to the decision to demolish and build a complete new school..
Ny konstruktionslösning och kostnadsförslag för stansverktyg
The task for this thesis is to design a tool that is used to cut-out preforms of thermoplastic adhesive and also to make an estimate of costs for the stamping tool. The tool is used in the repair process at the MCM production line.
The result of gathered information has affected how the design of the stamping tool has developed. The handling of thermoplastic adhesive in the repair process is one of the factors that influenced the design. The adhesive is sensitive for exposure to Moisture. Therefore an automated feeding system of the adhesive is not recommended.
The users wished for an automated stamping tool.
Smarta Hus: Nya behov och lösningar med participativ design
In this Bachelor Thesis (20 p.), we present the history and development of
"Intelligent Houses", and most important- explore some of the future
possibilities in this area.
The project has been carried out through an interdisciplinary cooperation
between three different educations at the Blekinge Institute of Technology.
By conducting a dialogue with various actors with different professions, we
have been trying to identify needs within the concept of "Intelligent Houses",
were the end user is not only the tenant or homeowner.
Through Participatory Design methods, such as a Future Workshop, we have
brought the users together to discuss their own and each others needs and
hindrances in their respective work practice, and how intelligent house
technology could improve their work conditions.
We have also been testing a highly sophisticated
CO/CO2/Moisture/Temperature/Enthalpy multi-sensor & controller, originally
developed for regulating indoor climate systems.
Based on the needs we have found in our fieldwork, we have been looking at
possibilities to make multi user solutions with the sensor..
Effektivare hantering av foderspannmål : en fallstudie
The purpose with this work was to investigate some alternatives for an effective handling with grain, to find the most economic alternative.
It is not common that Moisture content is below 14% when harvesting grain in Sweden. To store the grain safe it has to be preserved in some way. I have described some of the most common systems for preserving grain in this paper. I have used the systems as a basis when I made calculations in handling the grain for a company.
I have chosen a company placed in south of Sweden. The productions are crop farming and pork.
Ytbehandling baserad på hampolja
The varieties of paint are today very big, but many of the more popular paints are less than environmental friendly. The uses of fossilized fuel in paints are common because these paints dry fast and are color true. It would be beneficial for the environment if more renewable source were used to produce paint. Linseed oil is an old base for oil paints. It is renewable and easily procured.