Sökresultat:
1233 Uppsatser om Load-carrying capacity - Sida 2 av 83
Påbyggnad av våningsplan medlättkonstruktion : En jämförelse av stommaterialen trä ochtunnplåt
The purpose of this thesis is to examinethe possibilities for adding a floor to anexisting building using the two materialswood and sheet metal profiles as the loadbearing structure. An apartment buildingfrom the 60s has been used as referencehouse. Two different suggestions for thedesign are presented in the rapport. Oneof them has been analyzed with wood andsheet metal as the load bearing structure.Using the old constructional calculationsand blueprints of the existing buildings,the load bearing capacity has beencalculated. In the calculation programFEM-Design the building has been testedwith the loads that an extra floor wouldgive.
Två nya trailerkoncept för transport av rundvirke hos Stora Enso : en analys av prestation och flexibilitet
The need for roundwood transport capacity vary throughout the year. The need during a period is influenced mainly by the volume transported the period, the number of days during which transport can be carried out, seasonal variations in road conditions and the weight of the roundwood, and the origin of the wood (private forest owners/ forest companies). The need for transport capacity generally increase during the winter and in spring, after thawing. Lack of logging trucks combined with a lack of drivers for these trucks make it hard to hire extra help during periods of increased transport capacity needs. It is also very expensive to keep logging trucks for use only during these periods.
In this thesis, two new concepts based on the partial transport by truck tractors have been examined, to find out the possibility for increased performance and flexibility.
Utvärdering av ett Bränslecellsdrivet Flygplan.
With the increases in fuel costs due to the depletion of the world oil reserves and the increase of greenhouse gasses as a consequence to using oil as a fuel many companies are looking to new and innovative ways to power their aircraft. One of these new ways to power an aircraft is using fuel cells powered using hydrogen and oxygen, thus producing nothing but water vapour and small amounts of nitrogen dioxide as well as trace amounts of other emissions. Both Boeing (1) and Politecnico di Torino (2) have shown that it is possible to build an all-electric aircraft powered by fuel cells. Both flights used small, two-seater aircraft and a constant between them was the loss of the co-pilot seat due to weight and lack of space. As this paper will deal with a commercial aircraft a primary concern is the cargo and passenger capacity and whatever impact switching propulsion system has on these.
Momentbärförmåga för semikompakta ståltvärsnitt av HSQ-balkar : En modell för interpolering mellan eurokodens klass 2 och 3
The current standards for design of steel beams are divided into four classes based on the slenderness of cross-sectional parts. Depending on the section class a beams load capacity is either determined by a plastic, elastic or a reduced elastic model. The division between cross-sections calculated by a plastic and an elastic model is today done in a very harsh way with no smooth transition. This leads to a large difference in the calculated resistance for the sections located near the class limits. Elasto-plastic sections are in the current situation calculated as purely elastic and their large plastic reserve is not considered in the current standards.
Buntning av grot med lastbilsmonterad utrustning :
During the transportation of logging residues (LR) the material´s low density is a problem that results in low use of pay-load capacity. Comminution or compression of LR are possible methods to increase pay-loads. In the present thesis studied a bundling machine which was mounted on a truck chassis, and the subsequent transport and crushing. The truck bundler created bundles that were larger and longer than other bundling equipment on the market. The objectives were to determine the total time consumption and its allocation over work element and machinery, to measure dry matter (DM) content of green and brown LR-bundles.
Vindkraft och elbilar på Öland år 2020 : Är smart laddning av elbilar lösningen på ett framtida flaskhalsproblem?
The Island of Öland has one of the best wind climates for land based wind power in Sweden. An objective for the Island is to become self sufficient using electricity from renewable source of energy such as wind. There is currently 55 MW capacity installed on the Island and it is estimated that grid congestion will occasionally occur if more than 135 MW was installed.The aim of this thesis is to investigate he possibilities for load management by smart charging of electric vehicles, EV. The definition of smart charging is that the charging is done to some extent with an ICT-system, (information and communication technology) that correlates wind electricity generation to the charging of electric vehicles. The purpose is to avoid grid congestions on the sub-sea cable that connects Öland to the mainland because that in turn would curtail wind energy production.
Spänningsstyrd underfrekvenslastfrånkoppling i elektriska kraftsystem
This report is a Master?s Thesis performed by Andreas Adolfsson and David Jacobsson atChalmers University of Technology. The purpose of this master?s thesis is to evaluate anew method for load-shedding, the voltage controlled underfrequency load-sheddingdeveloped by ABB. This report presents a comparison between conventionalunderfrequency load-shedding and this new method for load-shedding.
Inventering av värmelager för kraftvärmesystem
When a combined heat and power plant produces heat and power it often faces a deficit of heat load during the summer or other periods of time. This heat is often unnecessarily cooled away or the power production has to be reduced or shut off. If it is possible to store heat from periods with low heat demand to periods with high heat demand one can get many benefits. Among these benefits are: increased power production, decreased operation with partial load, uniformly distributed load.To be able to store heat in situations like this long-term thermal heat storages are needed. In this thesis five different types of stores are presented: rock cavern storage, tank storage, pit water storage, borehole storage and aquifer storage.
Acceptansgränsen för solceller i lågspänningsnät : Kan den ökas?
Microproduction, also called distributed generation, is something that has become more and more popular in the electric grid. Microproduction can however lead to unacceptable performance if several units are installed in the same low voltage network. It is therefore good to know a limit where the performance of the low voltage network becomes unacceptable based on given parameters. This limit is usually called hosting capacity.In this report the hosting capacity with respect to voltage and current have been studied in three low voltage networks which are located in Falu Elnäts concession area. This has been done by simulations in a GIS-program where critical times of the grid have been simulated.
Utvärdering av den bärande tegel- och betongstommen i en byggnad från år 1916
This Master thesis is about a postal- and telegraphic building in Eskilstuna, Sweden. The construction methods for the specific building and buildings in general from the same time are described. The purpose of the report is to describe the loads acting on the building and how it has been built and why it has been rebuilt during the years. After this, possibilities of reconstruction and adaptation for today?s demands can be evaluated.
Persontäthet vid utrymningsberäkningar : Köpcentrums persontätheter
The aim of this study is to evaluate whether the value of occupant load is over or under estimated when the Swedish general value for department stores, 0,5 person/m2, is used for dimensioning shopping centers. The data that was analyzed derives from seven shopping centers and one department store. A conservative method was used to calculate the occupant load factor. The analysis shows that two groups can be discerned: one group that is characterized by a lower occupant load factor that does not exceed 0,3 person/m2, and one group with a higher occupant load factor. Shopping centers with a higher occupant load factor are located centrally in large urban areas.
Bättre åtkomst till avverkningstrakter med anpassat marktryck från avverkningsmaskinerna
The global climate-change means increasing mean-temperature and higher precipitation in Sweden, which leads to shorter periods of frozen ground in the forest. At the same time the harvesting machines are getting bigger and more powerful. The forest industry aim at an even wood flow, and the ground damage has to be as low as possible. The two biggest causes for ground-damage is the bearing capacity of the forest ground and the ground-pressure of the harvesting machines. The aim of this study was to find out some rules for the machine choice considering ground pressure, when harvesting on ground with low bearing capacity.A field study, using a Valmet 890.3 forwarder, was carried out where different ground pressures and their effect on the ground were tested on two different types of ground.Additionally, an inventory of damaged harvesting grounds was made.
Analys och kontroll av hållfasthet på grenställsarm
The thesis was done in collaboration with EAB situated in Smålandsstenar. In the initial discussion faze on doing a thesis with them there was a need to analyze and ensure the strength of an existing product, cantilever racks. This included performing FEM calculations on a model and comparing the results with physical tests.EAB has two models of cantilever racks, a light duty and a heavy duty. Within the heavy duty model series there are five product variants that differ in both size and load capacity. We will be working with the product variant with a load capacity of 1000 kg/arm which is the variant that is in the middle of the series.When we started work on the thesis we did a literature study and couldn?t find any well defined methodology that integrates both product development and computer aided design analysis.
Energiewendes påverkan på det nordiska kraftsystemet
Both the German and the Nordic power markets are seeing dramatically changed conditions due to an ongoing process of expanding the share of renewable production in the systems. For the German part this comes from heavy subsidies which have led to an explosive development in installed capacity of photovoltaic and wind based production. After the Fukushima incident it has been decided to shut down all Germanys nuclear plants. This capacity drop is however not of the same magnitude as the
increase in renewables, but will impact the stability of the power system. The Nordic power system which already has a surplus of power sees an even further increase, coming mainly from construction of new nuclear plants in Finland and a general increase in wind farms.
Analys av spänningsstabilitetsberäkningar i det svenska elsystemet
Numerical simulations play a vital role in both static and dynamic stability assessment of electric power systems and the foreseeing of voltage collapse. Simulations performed by Svenska Kraftnät(SvK) are mainly done in the specialized voltage collapse predicting software tool, SPICA and the more all?purpose software tool, ARISTO.The grid operators at SvK use SPICA to predict the maximum transfer limit at specified sections (in this report the section in concerns is the southern part of Sweden i.e. interface1 4). SPICA is mainly used as an online application by using actual states from the grid, these states update every quarter of an hour.This thesis is a continuation of the master thesis SPICA ? ARISTO JÄMFÖRELSE by Jakob Katzman and Johan Fält.