Sökresultat:
666 Uppsatser om Indoor temperature - Sida 2 av 45
Tilla?mpning och simulering av naturlig ventilation : Potential fo?r utnyttjande i kontorsrum
Mechanical ventilation is the most common type ofventilation in newly constructed office buildings. Therehas been an interest to utilize natural ventilationinstead of mechanical ventilation among architects andHVAC consultants in recent years. This is due to thesize of mechanical ventilation systems, which arespace consuming. The mechanical ventilation system isalso complex and requires maintenance. Furthermore,the fan uses a considerable amount of energy.
Kirunametoden-Jämförelse emot en konventionell injusteringsmetod
AbstractWith increasing population and increasing demands for comfort and thus an increase in energy demand, it is necessary to examine various energy-efficiency measures. This work deals with the ability to control the flow through the heating system to achieve the desired comfort with as little energy as possibleA heating system contains of different parts, roughly speaking, you can divide it to three main components: Heat source, Distribution and Heat emitters. All components are working together to bring heat to the building. What is examined in this report are different ways of adjusting the flow and supply temperature and how it affects comfort and energy use in a building.At today ?s date the conventional method is to use a high flow through the heating system, which affects pressure drop and cooling of the fluid.
Utvärdering av befintliga passivhus : En byggnadsfysikalisk bedömning och mätningar om temperatur, och fukt analys på ytterväggarna
Energy price are on the way up to a high level that will not diminish in the future make us to focus more on the sustainable development for a better solution of residential houses. Passive house or low energy housing are one of the solution to make residential more environment friendly, in same time it´s a financial security using less energy, and saving money. The last 10 years in Germany and all around Europe the concept of passive house been developed, and people aim to know more about these concept that leading the market more attractive for passive houses. A passive house is a well designed building highly insulated and air tight with mechanical ventilated system for the whole building envelope that minimizes the use of energy for heating [1].The housing company Mimer has chosen to invest in low energy consumption in every new housing project. These future plan projects are decided to use less than 75 kwh per square meter annually in purchased energy [2].This thesis is about new constructed passive houses, and focuses on the evaluations of the temperature, and moisture condition for attic, external walls and joist.
Metoder för lastprioritering i fjärrvärmecentraler
A problem in the field of district heating is the oil burners needed to provide power when a peak load occurs. One possible way of reducing the needed amount of oil is to reduce the power demand for space heating in the district-heating substations when the need for district heating water exceeds a certain limit. This can be done by use of a locally working controller function.In this Thesis the options concerning load priority are evaluated. To evaluate the potential for using controller functions concerning peak load priority an experiment was brought out in a chosen district-heating substation. The impact on the indoor thermal comfort during a heat reduction was also taken into account.
Lagring av kyla med horisontella markvärmeväxlare för kylning av koncepthus i Mellanöstern
Norconsult AB has developed a solarhousing concept, a house designed for the warm climate in the Middle East andwith large quantities of solar panels installed. The cooling system for the house was designed in an earlier report, the purpose of this thesis is to investigate the possibility of short and long term storage of thermal energy via an underground energy storage volume.Two different designs of the storage and three different filling materials have been integrated into a model to simulate different cases. The first design consisted of pipes installed in the ground, without insulation. The second design consisted of an insulated concrete box installed to prevent thermal energy from the surrounding soil to flow towards the lower temperature regions within the storage. The three different filling materials were dry saudi sand, water saturated saudi sand and the filling material used by the client for energy storage in Sweden.The results from the simulations show that neither of the designs, regardless of the filling material, managed to extract enough thermal energy from the house to the ground to uphold the demands of indoor climate.
Kroppstemperatur och vattenavdunstning via huden hos extremt underburna barn vid vård i kuvös och med kängurumetoden
Aim: To examine the reaction of extreme preterm infants with regarding to body temperature and transepidermal water loss during skin-to-skin care according to Kangaroo Mother Care (KMC) during the infant?s first week of life. Method: This was a descriptive quantitatively designed study, which was a pilot study within the framework of a larger project. Nine children, with a median gestational age of 24.91 weeks, were examined by measuring body temperature (axilla and skin temperature) as well as transepidermal water loss before, during and after KMC. Results: The study showed that skin temperature tended to rise during KMC, especially for those children who were nursed with KMC for more than 60 minutes.
Fö?rskolans inomhusmiljö? i relation till barns lä?rande : En studie om pedagogers arbetssä?tt på två Reggio Emilia-inspirerade förskolor
Background: The request for the Reggio Emilia practice has expanded enormously the last couple of years within the Swedish preschools. This particular practice describes the environment as a third educator. This third educator is supposed to work as - not only a tool - but also a support to ease children's learning experiences and help develop their mind. Previous research has shown that design of, for instance, furniture has a way of affecting the children's learning process and development.Aims: The purpose of this study is to see how two different teams of preschool educators on two differed Reggio Emilia inspired preschools work and handle the physical indoor environment. Method: We started out by contacting Reggio Emilia inspired preschools.
Utomhusgym, några fördelar? : En studie om affekter vid styrketräning inomhus respektive utomhus
PurposeThe aim of the study was to examine the affects perceived by young people aged 18-19 years old after resistance training outdoors versus resistance training indoor. The aim of the study was also to examine if the rate of perceived exertion was affected by whether the resistance training took place outdoors or indoors. What immediate affects are perceived in conjunction with resistance training outdoors and indoors in people aged 18-19 years?What immediate affects are perceived after resistance training outdoors compared to equivalent resistance training indoor in people aged 18-19 years?What perceived exertion level can be seen in conjunction with resistance training outdoors compared to equivalent resistance training indoors in people aged 18-19 years?How does exercise habit correlate with affects and exertion in conjunction with resistance training? Method22 pupils in a secondary school conducted two resistance training sessions, one outdoors and one indoor. A questionnaire about their mood and exercise habits was answered before and immediately after the training session. Rate of perceived exertion rate was also included in the questionnaire the participants received after the workout.
Test och verifiering av en ny inkapslingsmetod för SiC BJT och MOSFET
The use of silicon carbide (SiC) as a base material in power electronics has manyadvantages, including high breakdown voltage and excellent temperature endurance.However, the packaging of such electronics presents major challenges and there is aneed for packaging that can operate in higher temperature. The purpose of this thesishas been to develop a test method and verify the functionality of SiC powertransistors prototypes with a new packaging technique developed by Swerea IVF AB.It includes setting up an electrical test-bed for power and high temperature cyclingand analysis of the results. Even though test confirmed functionality after thepackaging process, (at room temperature) the performance seemed to have been reduced. This could be a result of the measurement setup and the packaging process.In higher temperature the transistors failed to operate longer than a couple ofminutes which showed the weaknesses in the design and the challenges with this typeof packaging..
En pilotstudie av unghästars användning av ligghall i grupphållningssystem
Today, individual indoor stalls and individual outdoor paddocks are the most common way to house horses in Sweden. The way that we manage, house and feed the horses are not optimal for the species natural basic behavioural needs. However, the awareness of this grows in the context of research and the emergence of alternative housing systems. One of the alternatives to the traditional format in individual boxes is called group housing. Group housing systems allow horses to live in herds and they can choose how they want to distribute the hours of the day between movement, resting and foraging.
The purpose of this study is to examine how frequently the young horses in a group housing system use the indoor lying area.
Den fysiska inomhusmiljöns effekt på ettåringars sociala samspel
The aim of this study is to look at the environmental effect on toddlers? social interactions during free play in two older and two newer preschools. Furthermore, we would like to investigate four preschool teachers? thoughts about the indoor environment when it comes to toddlers? interaction during free play.Qualitative methods containing interviews of the preschool teachers and observations of the children during their free playtime have been used to help us reach our conclusions. In addition, our theoretical conclusions have been derived from both the sociocultural perspective and the environmental psychology perspective.Our results have shown that variations in the preschool environment are of importance in the outcome of toddlers? different social interactions.
Indoor Positioning Using WLAN
This report evaluates various methods that can be used to position a smartphone running the Android platform, without the use of any special hardware or infrastructure and in conditions where GPS is unavailable or unreliable; such as indoors. Furthermore, it covers the implementation of such a system with the use of a deterministic fingerprinting method that is reasonably device independent, a method which involves measuring a series of reference points, called fingerprints, in an area and using those to locate the user.The project was carried on behalf of Sigma, a Swedish software consulting company..
Inomhusmiljöproblem i fuktiga byggnader : En utredning av åtgärder vid fuktrelaterade inomhusmiljöproblem
Dampness in the indoor environment have been a major issue of discussion the last decades since more and more people complain about their indoor environment. In the present situation there are difficulties to find what causes people?s discomfort in a damp environment even though there is a strong connection between dampness and human health.The aim of the thesis was to contribute to the work done today to achieve a better indoor environment in damp buildings. The purpose of the work was to evaluate whether the measures issued for dampness in the indoor environment contributes to the improvement of health and environment for those who are living or working in that space. Through a literature review, interview and survey the following three questions were answered to achieve the aim and purpose:How are people affected by the indoor environment in damp buildings?Which are the measures issued to prevent dampness in the indoor environment?Do these interventions contribute to a better indoor environment?How people are affected by the indoor environment in damp buildings and how these problems are prevented were the foundation for the continued work with the survey.
Inomhuspositioneringssystem : Utvecklande av server-funktionalitet, klient-kommunikation och en grafikmotor
The projects goal was to make an already existing indoor positioning system useful forthe average smartphone user. This was achieved by creating an Android applicationwhich, along with a running server, continuously presents the user with all the currentneeded information. It uses the graphics engine andEngine to create the graphical userinterface. The application was created in the development environments Eclipse andAndroid Studio..
Skadliga nollflödespunkter i Fortum Värmes fjärrvärmenät i Stockholm : En analys av dess förekomst och effekter
When several production units provide a district heating network, water is pumped from different directions. When the flows from the plants finally meet in the network, the water can be completely still. These places are called zero flow zones. In district heating networks with several plants, which also have different supply temperatures, large and frequent temperature fluctuations can occur when the zero flow zones move. This may cause wear on the pipes, a phenomenon called low cycle fatigue.For this reason it is important to examine where and when zero flow zones that cause temperature changes occur.