Prestandaförändringen hos en bergvärmeanläggning efter fem års drifttid
The aim of this report was to do a case study at a geothermal heating system which has been in operation for about 5 years, and study if its performance has changed during this period of time. A literature study about the processes involved was also done in purpose of background knowledge.The tenant-owner?s association Duvan at Petterslundsgatan in Uppsala installed year 1999-2000 a geothermal heating system. The purpose of this installation was that they hoped it would lead to a smaller usage of district heating which would lead to a reduction of the heating expenses for their buildings. The geothermal heating system consists of 19 energy wells and 4 geothermal heat pumps, and it is one of the first systems of that size in the region of Uppsala.
Effektivare energianvändning på Totebo AB
The main goal with this thesis report was to come up with ideas of how to make the use of energy more effective and thus save money for the company.First a survey was made to find out where and how the energy consumers were divided within the company. The results were then used in calculations to find out how much money that could be saved and how long it would take to get back the investments.There is a big potential in saving money by recovering heat from the UV-lamps with a heat exchanger. It would also even out the pressure in the factory which is a source to heat loss and a cause for discomfort amongst the employees. It?s possible to save 105 000 kr in a year and the money needed for the investments is 600 000 kr.By using the recovery air more effectively the company could save up to 250 000 kr a year in lowered heat purchases, but this would require the use of automatic dampers.If you reschedule the running times for the wood chipper and invest in some kind of load management, for example Sydkraft?s ?Energidirigent? you can save at least 42 000 kr.
Beräkning av värmeförluster och energieffektivisering av elbussar
The ?civilized? world is in need of fossil fuel in order to function. Hybricon AB is a company in Umeå that is developing a technology that hopefully can reduce parts of this need. They are currently testing their two electrical busses (with Hybrid backup) in city traffic on the roads of Umeå in cooperation with the county of Umeå. The busses are originally diesel-busses, but the diesel motor has been replaced with two electrical hub-motors with a power of 145 kW each that are powered by batteries.The batteries are charged at the end station after each route. In case the batteries should run low on capacity during driving, they can be recharged by the so called genset.
Jämförelse av solhybrider
Research in solar energy is taking big steps in both solar heating and solar electricity. It´s not only the technologies alone, but also the combination of both solar electricity and solar heating which is what is called a solar hybrid. The idea of a solar hybrid is that a solar cells efficiency decrease with increased temperature and can with help from a solar collector be cooled and the heat can be utilized. This thesis report compares heat production and electricity production with respect of, in first hand, a solar hybrids geometry in the cooler. The theory chapter describes solar heating and how different solar cell technologies work and their environmental impact at the production and how compatible these technologies are for the solar hybrid.
Hållbara uppvärmningsalternativ för hotellstugorna på Grinda : En kvantitativ studie gällande hållbara uppvärmningsalternativ på en skärgårdsö
Skärgårdsstiftelsen, which is responsible for several of the archipelago islands in Stockholm, has chosen to explore the possibilities for more sustainable heating systems in buildings on the islands in collaboration with KTH. A reduction of energy use and improving the efficiency of existing heating systems are included as part of the environmental work. This report studies the island of Grinda, which is located outside the area of Vaxholm in Stockholm. The study area consists of a guesthouse consisting of a restaurant as well as conference facilities and four neighboring cottages used for overnighting. The cottages now run solely on direct electricity, both for heating and hot water.
Utvärdering av ett större bergvärmesystem i en flerbostadsfastighet som har konverterats från fjärrvärme
This master thesis is an in-depth study of an existing heating system at a household cooperative in Uppsala that has been converted from district heating to a bedrock heat pump system. The study focuses on an economical system optimisation of the building?s complete heating system. The aim was to determine how well a heat pump system in large buildings actually work, find out possible ways to optimize the existing system and point out important system parameters for new heat pump installations in larger buildings.The project points out a possible energy cost reduction of 45 % without investment and further cost reductions with equipment investments. A reduction by 30 % is possible by improvements in the regulation system and 15 % is possible by maintaining the brine system.
Artificiell insemination av får
AbstractThe purpose of this bachelor thesis is to describe the use of artificial insemination (AI) in sheep and discuss the possibilities for AI in Sweden. Male and female fertility, heat detection, semen handling and insemination techniques in sheep are described. Advantages and disadvantages of AI are discussed. In order to achieve genetic progress it is important with well planned and implemented breeding programs. The Swedish Sheep Recording Scheme and computer software from Elitlamm are the basis for sheep breeding in Sweden.
Kyla i Nyköping och Motala : Kartläggning av kylapotential för Vattenfall Värm
The Swedish energy company Vattenfall is currently the owner of the district heatingsystems in Nyköping and Motala. To be able to also offer cooling solutions tocustomers are becoming more and more important. This report describes the resultsof an investigation of the cooling market in the two cities and the potential needs forcooling today and in the coming 20 years. The total potential for the coming 20 yearsis estimated to be roughly 17 MW for Nyköping and 9 MW for Motala.Two possible district cooling systems for each of the two city centers was modeledand a comparison was made between different cooling techniques namely absorptionand compressor chillers.Absorption chillers driven with district heating during the summer is one way ofincreasing the load in a combined heat and power plant and thereby the possibleelectricity generation. The cost of heat production must be low for absorption chillerto be able to compete as an alternative.
Enegiutredning Hotell Princess
This report will show the energy usage of Hotel Princess in Sandviken, Sweden. When the hotel changed owner an examination of the hotels heating, ventilation and sanitary systems were done. The report showed flaws in the ventilation system, and is why the new owner wanted a closer look at the energy use of the hotel. The original building was built in the 1930s and two major extensions have been built, one in the 1950s and the most recent in the 1980s. An assumption made is that the building parts were built to the restrictions during the time. Activities on the hotel include sleep over, conference, night club, massage and swimming in the hotels pool section.
Expansionsmaskiner istället för strypventiler - en effektivisering
In Uppsala CHP Plant, there are six pressure reducing valves to reduce the pressure from 15 to 3 bars, before six absorption heat pumps. During the process the energy is conserved but losses occur in form of exergy. The aim of this thesis is to reduce the losses of exergy. This can be done by letting turbines replace the pressure reducing valves.In this thesis an investigation has been done of the conditions today, the conditions after the change from pressure reducing valves to turbines and a comparison of three different types of turbine solutions. The three examined solutions are one turbine, several helical screw expanders and several small turbines in parallel with asynchronous generators.The six absorption heat pumps have been divided into two groups; one group of four and one group of two absorption heat pumps.
Uppvärmd konstgräsplan : Beräkning av utnyttjningstid för en uppvärmd konstgräplan med alternativa rörplaceringar
For Skattkärr IF a turf field with warming has been projected to increase field?s utilization hours and to have a longer period for athletes to perform their activities outdoors. The technique chosen to heat the plan is a type of a geothermal heating system without a heat pump. The brine, which is water with 30% ethanol, collects heat from the borehole and discharges it to a coil in the field. There is at position 11 boreholes but it is planned to increase the number to 31, which is the design for the facility.
Utredning av solenergi för drivning av sorptiv kylprocess för inomhusluften på Stockholmsarenan
Cooling down the indoor air can be done in several ways. One way is desiccantcooling which will be used at the Stockholm Arena. This method is used in airhandling units that use temperature changes and moisture fluctuations in the air. Oneof the steps is to add heat during the cooling process in order to reduce the relativehumidity of the exhaust air. The air passes thru an adsorptions rotor which thenabsorbs moisture from the supply air.
Återvinning av industriell restvärme som värdeskapande process : En fallstudie på SSAB EMEA i Borlänge
The industrial sector accounts for a large share of greenhouse gas emissions. To reduce its negative impact on the environment is crucial in the quest for a sustainable future. In discussions of the industrial sector's impact on the environment guidelines have been highlighted as a tool to assist the industries in their efforts to change the relationship between the consumption of energy and production. This by improving energy efficiency and a shift to the best available technology. During the past 30 years the steel industry has reduced its energy consumption per ton of steel produced by 50 percent.
Det energiproducerande huset
We are heading towards a huge switch of how energy is produced with fossil fuels being replaced by renewable energy sources. It is not difficult to replace the energy you use in the house and there is no need for futuristic technology. There are already many established products on the market such as high efficiency vacuum solar collectors, heat pumps & small wind power stations that can supply the energy being used in a house. The company Sol & Energiteknik SE AB in Huskvarna has many different products which can reduce the need for an outside energy distributor. An average house in Sweden uses 15 000 kWh for heating, 5000 kWh for tap water and 5000 kWh for electricity.
Produktutveckling och prestandatest av ett vattenvärmedrivet torkskåp : Jämförelse mellan tre utvecklade versioner av ett vattenvärmedrivet torkskåp
AbstractElectricity consumption is a globally increasing problem caused by the high share of electricity produced in coal power plants. These contribute to high carbon emissions when only about 1/3 of the heat generate electricity and the remaining 2/3 of the heat cools off. Combined heat and power plants (CHP) have high efficiency because they use the residual heat for domestic heating. The CHP plant often use fuels from renewable resources, giving them a lower carbon footprint, but are also depending on the heat demand. If electric powered products such as drying cabinets convert to heat powered products more environmentally friendly electricity will be produced by CHP plants, which can supplant electricity, produced from coal power plants and reduce carbon emissions.