Sökresultat:
656 Uppsatser om Heat Pumps - Sida 8 av 44
Igensättning av övre spalten i centrifugalpump
This report focuses on the upper slit. The upper slit is located between the impeller andthe drive unit. The slit design depends on pump type and application. However it isuncertain why the design varies, The purpose of this report is to clarify why the designvaries and to recommend an improved slit design.A research has been done; information was gathered from interviews, but also fromsearching of databases and studies of drawings, reports and documents. The originalpurpose of the slit was to prevent twining around the driveshaft, and prevent dirt fromentering the cooling system.
Biogas på Wapnö : Analys av framtida energisystem
Considering that the price and demand for energy gradually has risen over the past decade and a wider discussion about the human impact on the environment has become increasingly more important and given a clearer role in modern society. This has contributed to increased incentives to reduce the use of fossil fuels and increase the use of renewable energy.The agriculture currently accounts for 20 % of Sweden's total greenhouse gas emissions. A way for an agricultural company like Wapnö AB to reduce their emissions could be to utilize existing renewable energy sources within their own premises.The report's aim is to create an energy audit of Wapnö?s existing energy system and how it changes with a future biogas plant in operation. The energy audit is used to illustrate how the company?s climate footprint could change.
Analys av massapumps- och mixerarbete vid Metsä Board Sverige AB, Husums Fabriker : Energibesparingsåtgärder vid blekeri 4 & 5 med jämförelse mot ny utrustning
Husums plant has a selection of different pulp pumps at bleaching plant 4 and 5. The displacement- (HC-pump, Sund Defibrator PTD-60) and centrifugalpumps (MC-pump, MCA 42-200, MCP 30/20) are of interest in this report. The centrifugal pumps are controlled by throttle valves, which result in an energy loss. Chemical mixers are used to mix ClO2 into the pulp before proceeding into a holding tower where the bleaching process occurs.The energy demand of the different positions has been measured or calculated to be used in comparisons against new equipment. Quotations were requested and delivered from Valmet and Sulzer.
Passivhus vid polcirkeln : Fungerar det?
This report is the product of the course AF101X, a bachelors degree in Samhällsbyggnad atKTH. The task of the course is to design a small house at a given location and also implement adeepening study. The house in this report is located in Kiruna in the north of Sweden, where theclimate is much colder than in the rest of the country.The deepening study of this report is to evaluates how realistic passive housing north of thePolar Circle is based on those facts. The house will to some extent be designed to fit the passivehousing standard.
Energikartläggning vid biogasanläggningen, Kungsängens gård
The purpose of this thesis was to make an energy survey and quantify energy flows of
individual unit operations associated with the biogas production in Uppsala Vatten och Avfall
AB:s biogas plant, located at Kungsängens gård. Moreover, large consumers of energy would
be identified and analyzed. The objective of this energy survey was to obtain a detailed
understanding of the energy use in the biogas production.
The energy survey was divided into two parts: electricity and heat. Each part was treated
separately and with somewhat different approach. To estimate the electricity usage during the
projcet the rated power of each selected unit operation was noted and multplied with the
measured time of usage.
Energikartläggning av biogasanläggningen, Kungsängens gård
The purpose of this thesis was to make an energy survey and quantify energy flows of individual unit operations associated with the biogas production in Uppsala Vatten och Avfall AB:s biogas plant, located at Kungsängens gård. Moreover, large consumers of energy would be identified and analyzed. The objective of this energy survey was to obtain a detailed understanding of the energy use in the biogas production.The energy survey was divided into two parts: electricity and heat. Each part was treated separately and with somewhat different approach. To estimate the electricity usage during the projcet the rated power of each selected unit operation was noted and multplied with thenmeasured time of usage.
Effektivare energianvändning på Totebo AB
The main goal with this thesis report was to come up with ideas of how to make the use of energy more effective and thus save money for the company.First a survey was made to find out where and how the energy consumers were divided within the company. The results were then used in calculations to find out how much money that could be saved and how long it would take to get back the investments.There is a big potential in saving money by recovering heat from the UV-lamps with a heat exchanger. It would also even out the pressure in the factory which is a source to heat loss and a cause for discomfort amongst the employees. It?s possible to save 105 000 kr in a year and the money needed for the investments is 600 000 kr.By using the recovery air more effectively the company could save up to 250 000 kr a year in lowered heat purchases, but this would require the use of automatic dampers.If you reschedule the running times for the wood chipper and invest in some kind of load management, for example Sydkraft?s ?Energidirigent? you can save at least 42 000 kr.
Beräkning av värmeförluster och energieffektivisering av elbussar
The ?civilized? world is in need of fossil fuel in order to function. Hybricon AB is a company in Umeå that is developing a technology that hopefully can reduce parts of this need. They are currently testing their two electrical busses (with Hybrid backup) in city traffic on the roads of Umeå in cooperation with the county of Umeå. The busses are originally diesel-busses, but the diesel motor has been replaced with two electrical hub-motors with a power of 145 kW each that are powered by batteries.The batteries are charged at the end station after each route. In case the batteries should run low on capacity during driving, they can be recharged by the so called genset.
Jämförelse av solhybrider
Research in solar energy is taking big steps in both solar heating and solar electricity. It´s not only the technologies alone, but also the combination of both solar electricity and solar heating which is what is called a solar hybrid. The idea of a solar hybrid is that a solar cells efficiency decrease with increased temperature and can with help from a solar collector be cooled and the heat can be utilized. This thesis report compares heat production and electricity production with respect of, in first hand, a solar hybrids geometry in the cooler. The theory chapter describes solar heating and how different solar cell technologies work and their environmental impact at the production and how compatible these technologies are for the solar hybrid.
Utvärdering av ett större bergvärmesystem i en flerbostadsfastighet som har konverterats från fjärrvärme
This master thesis is an in-depth study of an existing heating system at a household cooperative in Uppsala that has been converted from district heating to a bedrock heat pump system. The study focuses on an economical system optimisation of the building?s complete heating system. The aim was to determine how well a heat pump system in large buildings actually work, find out possible ways to optimize the existing system and point out important system parameters for new heat pump installations in larger buildings.The project points out a possible energy cost reduction of 45 % without investment and further cost reductions with equipment investments. A reduction by 30 % is possible by improvements in the regulation system and 15 % is possible by maintaining the brine system.
Artificiell insemination av får
AbstractThe purpose of this bachelor thesis is to describe the use of artificial insemination (AI) in sheep and discuss the possibilities for AI in Sweden. Male and female fertility, heat detection, semen handling and insemination techniques in sheep are described. Advantages and disadvantages of AI are discussed. In order to achieve genetic progress it is important with well planned and implemented breeding programs. The Swedish Sheep Recording Scheme and computer software from Elitlamm are the basis for sheep breeding in Sweden.
Kyla i Nyköping och Motala : Kartläggning av kylapotential för Vattenfall Värm
The Swedish energy company Vattenfall is currently the owner of the district heatingsystems in Nyköping and Motala. To be able to also offer cooling solutions tocustomers are becoming more and more important. This report describes the resultsof an investigation of the cooling market in the two cities and the potential needs forcooling today and in the coming 20 years. The total potential for the coming 20 yearsis estimated to be roughly 17 MW for Nyköping and 9 MW for Motala.Two possible district cooling systems for each of the two city centers was modeledand a comparison was made between different cooling techniques namely absorptionand compressor chillers.Absorption chillers driven with district heating during the summer is one way ofincreasing the load in a combined heat and power plant and thereby the possibleelectricity generation. The cost of heat production must be low for absorption chillerto be able to compete as an alternative.
Enegiutredning Hotell Princess
This report will show the energy usage of Hotel Princess in Sandviken, Sweden. When the hotel changed owner an examination of the hotels heating, ventilation and sanitary systems were done. The report showed flaws in the ventilation system, and is why the new owner wanted a closer look at the energy use of the hotel. The original building was built in the 1930s and two major extensions have been built, one in the 1950s and the most recent in the 1980s. An assumption made is that the building parts were built to the restrictions during the time. Activities on the hotel include sleep over, conference, night club, massage and swimming in the hotels pool section.
Uppvärmd konstgräsplan : Beräkning av utnyttjningstid för en uppvärmd konstgräplan med alternativa rörplaceringar
For Skattkärr IF a turf field with warming has been projected to increase field?s utilization hours and to have a longer period for athletes to perform their activities outdoors. The technique chosen to heat the plan is a type of a geothermal heating system without a heat pump. The brine, which is water with 30% ethanol, collects heat from the borehole and discharges it to a coil in the field. There is at position 11 boreholes but it is planned to increase the number to 31, which is the design for the facility.
Transientanalys för Forsmark block 2 och 3 : Studie av hur val av driftpunkt och pumpreglering påverkar torrkokningsgränsvärdet
The dry out criterion (MCPR) has been calculated for the most limiting H2-events for Forsmarks unit 2 and 3, at operating points that are normally not analyzed before each cycle. The operating points that normally are regarded as the ones with the lowest margin to dry out are the ones where the thermal power is the highest at agiven recirculation flow. This report shows that this is not the case for Forsmark 3. MCPR-values at partial power operating points are higher for the limiting case inside rather than on the boundary of the region of operation. It is therefore recommended that the method for determining the dry out criterion for Forsmark 3 is revised to account for this effect.