Frånluftsvärmepumpens möjligheter i flerbostadshus

If a building is heated by a heat pump, it is of high importance that the heat pump has a high coefficient of performance. An Exhaust air heat pump extracts heat from the building?s exhaust air. The air has a relatively high and constant temperature all year around, leading to a high seasonal coefficient of performance. This thesis examines whether it is profitable to complement an exhaust ventilation system with an Exhaust air heat pump in an apartment block that already has geothermal heat pump, district heating, oil- or biofuel heated system.

Jämförelse av frånluftsvärmepumpar

In order to reach the environmental targets, set up by the EU, there are many measures taken to make Sweden more energy efficient. In the housing and real estate sector, an installation of an Exhaust air heat pump that reuses the heat in the exhaust air in order to lower the amount of acquired energy, is an example of such an action. The recovered energy can then be used for heating of radiators and tap water. This report aims to evaluate and compare three different systems using Exhaust air heat pumps regarding COP, degree of coverage and cost savings. This study was delimited to only account for apartment buildings.The theory chapter describes the different conditions and factors that affect a building?s energy balance.

Luft/luftvärmepump : - Med möjlighet till återvinning

Sweden has long had access to low electricity prices due to the wide availability of hydro and nuclear power. This has now changed because of today's rising electricity rates resulting in increasing heating costs for properties, especially in the properties with electric heating systems."Ankaret" is a parish for "Svenska Alliansmissionen", which is located at "Gullbrannagården".The parish has installed electrical radiators and an exhaust ventilation system that makes the energy demand high due to the large ventilation flows. The building was built as the price of electricity was still low and would reduce energy use today by combining its heating system with an air/air heat pump. The heat pump delivers more heat into the room than the electrical energy that it uses. This lowers the electricity needs.

Solmodul jord- och bergvärmepump

An increasing number of heat pump producers have developed heat pumps that can be connected to solar panels. In this thesis we have examined the possibilities of connecting solar panels to existing ground source- and geothermal heat pumps that has not been adapted to solar panels. During the work process, a prototype plant has been built to compare our theory with the practical results and with our designed sizing tool. The work has rendered in knowledge that will be used to build a sun module that can be easily connect to the existing heat pump system. The existing heat pump, our test plant, has been supplemented by an advanced storage tank used to allow different operating modes.

Ljudreducering av värmepump

This degree project handles acoustic measurements of the heat pump EcoAir 107, made by Enertech CTC AB. The sound from the three sound sources of the heat pump, fan, compressor and four way valve, have been measured to find out how they affect the total sound level of the product.Measures to attenuate the sound level have been developed and tested. By comparing these with the sound of the heat pump, in its original state, we have found out the measures which have best effects.The best attenuating measures came to be: taped openings and holes around the compressor space, isolating the top and the bottom of the whole construction, support of the fan bottom part and shielding of the sound source with a screen at a distance of 110 mmThese measures have been tested together and an average attenuation of the total sound level with 3,9 dB have been accomplished. In the front of the fan where the continuous sound is the strongest, the attenuation was 4,7 dB.This project is meant to be used as a guide by Enertech CTC AB:s during their future developing process..

Studie av skyddsavstånd mellan bergvärmeanläggning och skyddsobjekt i ett vattenskyddsområde

During installation and operation of a geothermal heat pump system leakage of an antifreezing agent can appear in a borehole and leak out in surrounding groundwater. To guarantee high quality drinking water for generations to come Sweden has dedicated some areas as water protection areas. The local authority gives permits for the installation of heat pump systems within water protection areas. Before giving a permit the local authority makes an evaluation of the risks involved in installation and operation of the system within the area. By keeping a certain distance between the protected object in the area and the heat pump system the risk of polluting the protected object with an anti-freezing agent can be reduced.This thesis makes a comparison between three different methods of calculating an appropriate distance between the protected object and the heat pump system.

Hur byggnadsdetaljer ändrar fasadens uttryck

An energy study has been performed on two blocks in an area called Gävle Strand. The buildings are owned by a tenant-owner?s association called brf Carolina and were built by the company Skanska 2008. The builder as well as brf Carolina are pussled by the fact that electricity use is higher than expected while heating is less. Skanska is also very interested in finding out how much heat recovery from stale exhaust air through a geo-thermal heat pump is contributing to the general heating requirement and energy balance in four out of the ten buildings located on the properties.To find possible answers to the higher electricity use a literature survey on user behaviour was conducted.

Skalkonstruktion : Med inriktning mot hållfasthet och dämpning av ljud

The sound part is mainly practical and is dependent on concepts that have been tested through measuring with a sound level meter. The design part is more theoretical and has been verified with CAD models and finite element analysis.With a sound damping hood on the compressor the sound level is reduced with up to four dB. An optimized absorbent for the compressor space gives a reduction with three dB. By using the insulation for the heat water tank as absorbent we can see a sound reduction on the lover octave bands. A reduction like this is elsewhere hard to achieve as at it requires thick absorbents.By changing the today?s insulation to the heat water tank to a form of polystyrene polymer insulation the weight from the heat pump above can be transferred to the stable heat water tank.

Analys av energianvändningen i kvarteren Carolina och Jenny : en fallstudie

An energy study has been performed on two blocks in an area called Gävle Strand. The buildings are owned by a tenant-owner?s association called brf Carolina and were built by the company Skanska 2008. The builder as well as brf Carolina are pussled by the fact that electricity use is higher than expected while heating is less. Skanska is also very interested in finding out how much heat recovery from stale exhaust air through a geo-thermal heat pump is contributing to the general heating requirement and energy balance in four out of the ten buildings located on the properties.To find possible answers to the higher electricity use a literature survey on user behaviour was conducted.

Konceptstudie av Waste Heat Recovery System på Tunga Fordon

In today?s fast growing and closely connected society, a reliable and energy efficient transportation system is more than ever desirable. Nowadays the significant part of the transportation sector?s energy demand is supplied by fossil fuels.Improving energy efficiency in combustion engines will result in reduction of fuel consumption and CO2 emissions. A modern internal combustion engine has an efficiency of 30-45 %, where the most energy loss occurs as result of heat losses in the exhaust and cooling systems.

Värmeförluster vid utvändigt placerade ventilationssystem

To be able to handle tomorrows need for limited energy consumption we need to reduce our use of energy. The building sector stands for around 40 % of all energy consumption in the society. The government has put up a goal to reduce the energy consumption in our buildings with 20 % by year 2020 and 50 % by year 2050 compared with year 1995. To be able to do reach that goal we need a more energy efficient building stock.The main part of the energy used in our buildings is used for space heating. By installing ventilation systems with heat recovery on the exhaust air it is possible to use the heat-energy in the exhaust air to warm up the incoming air.

En kombinerad Organisk Rankinecykel och värmepump integrerat med ett fjärrvärmesystem : Där värme- och elproduktion samt lönsamhet studeras och avfall är huvudbränslet

The demand for district heating is expected to decrease in the future, due to competition from heat pumps and energy efficiency measures in buildings. Development of existing district heating systems is therefore necessary for district heating companies to maintain market shares. This Master?s thesis describes and investigates the heat and electricity production and profitability of a combined Organic Rankine Cycle (ORC) and heat pump that is integrated with an existing district heating system. The studied district heating system is utilizing heat from waste incineration. In Sweden waste constitute 20 % of the fuel mix used in district heating systems, and this share is expected to increase in the future.

Projektering av ett småhus samt ekonomisk jämförelse av värmesystem

Design of a house requires knowledge of both technology and economics. Heating and ventilation shall be designed, costs are calculated and estimated and requirements must be fulfilled. Which heating system is to be elected is also a difficult choice, especially with rising energy prices as a factor.The choice of energy system is not always given, because it depends on several factors. Below is a comparison between district heating, geothermal heat pump and electric boiler from an economic standpoint. In a previous report appears district heating and geothermal heat pump as the best options.

Vitvarueffektivisering med hjälp av värmelagring : Simuleringsstudie kring energiförsörjning av vitvaror med hjälp av värmepump & ackumulatortank

The constant need of energy is something that affects us all no matter our current situation. Whether we are driving our car to work, taking the elevator or using the oven to cook dinner we end up relying on energy. Our whole society is continuously striving to achieve a higher grade of efficiency and the process of supplying ourselves with energy is no exception. The importance of appliances in our everyday life cannot be exaggerated and thus the importance of their high efficiency.Efficiency is already a keyword in the appliance industry with labels, stars and numbers helping us choosing the most suitable option for the task ahead. No matter how efficient appliances often use pure electricity as their energy source.

Värmeöverföring i bergvärmesystem : En numerisk analys av den ringformade koaxiala borrhålsvärmeväxlaren

The borehole heat exchangers of today suffer from poor thermal and hydrodynamic performance. The purpose of this thesis is to improve the performance of ground source heat pump systems and thermal energy storages by increasing the energy efficiency of the borehole heat exchangers. For this reason, the annular coaxial borehole heat exchanger (CBHE) has been analyzed. This type of heat exchanger is interesting in terms of both thermal and hydrodynamic performance. A model has been set up in the program Comsol Multiphysics in order to investigate the heat transfer characteristics along the borehole.