Sök:

Sökresultat:

2394 Uppsatser om Energy efficient - Sida 5 av 160

Energieffektivisering av modern tillbyggnad till äldre skola : fallstudie från Österbyskolan i Österbybruk

The Swedish government has introduced a goal to reduce the energy intensity by 20% to the year 2020. To reach this goal actions need to be taken throughout the energy sector which includes residential and commercial buildings. This thesis considers the possibility to reduce the energy usage in a building located close to Uppsala. The analyzed building is a combined office, cafeteria and entrance and was completed about half a year before this project started. Therefore the measures presented for a more Energy efficient building are presented as measures for future constructions.Simulations have been made in VIP-Energy, a dynamic energy calculation program.

Utvärdering av energieffektiviseringsåtgärder på Bokelundskolan i Växjö

The purpose with this report is to examine how the implemented energy efficiency measures on Bokelundskolan in Växjö have had impact on the energy use. The measures which have been implemented are, new ventilation system, new heating system, optimized adjustment of the heating system, new windows with U-value 1.2 and lower window height, insulation under windows and in the crawl space. The school's energy use before and after rebuilding has been calculated with the calculation program, Vip-Energy 1.5.5.Calculations of energy use for the school with windows on U-value, 0.9 and 0.7 have also been done. The replacement of windows has been studied from a cost perspective. The conclusion is that the exchange of heat and ventilation system was the biggest contributor to reduced energy use on Bokelundskolan.

Energieffektivisering på Skutskärs Bruk : Varvtalsstyrning till utvalda pumpenheter på Blekeri 4

In modern society in terms of economics and environmental impact, it is important to ensure that a company is as Energy efficient as possible to reduce the amount of energy used. About 10 TWh of electricity used annually to pump drives in Swedish industry. Therefore, pumping system has great potential for energy savings.The objective of this report was to determine how much energy and money that can be saved with the insertion of variable speed drive to six pumps on Bleach plant 4 in Skutskär Mill. The work was performed with electrical measurements during one week, analysis of pump curves and the compilation of production data over a year.The results show that four of these six pumps were profitable and yielded an annual saving of 1172 MWh of electricity and 560 000 SEK. With an economic lifetime of 10 years and a discount rate of 6.8% the final result for the entire life-cycle savings became 3 355 000 SEK.

Renovering av flerbostadshus - en studie om energieffektivisering och lönsamhet

In today?s society a large focus is put on energy systems and how our energy systems are built up. In order to make sure that we in the future still can enjoy the living standards that we are used to today, Sweden and EU have made a number of decisions on making our energy system more Energy efficient and consequently reduce the usage of energy resources. By 2020 the European Union should have reduced its energy consumption by 20 % compared to 1990?s level, and by 2050, 50%.

Energieffektivisering och solenergi i en universitetsbyggnad : Undervisningshuset och Biblioteket i Uppsala

Akademiska hus is a real estate company that specializes in providing Swedish universities with housing facilities for educational and research purposes. The company strives to reduce its use of energy by 40% between the years 2000 and 2025. The aim of this thesis is to determine which measures can be taken to reduce the need of purchased energy in a building that is used by theSwedishUniversityof Agricultural Sciences inUppsala.In order to determine the results of various changes to the building envelope and ventilation system, the building was modelled in the computer simulation program VIP-Energy. Other proposed changes to make the use of energy more efficient concerned water use and lighting. The need of purchased energy can also be reduced by producing electricity or heat on site, using solar energy.Results show that economically viable measures include upgrading windows and faucets, adjusting control systems for ventilation and lighting, and installing roof mounted solar panels for power production.

Jämförelse av frånluftsvärmepumpar

In order to reach the environmental targets, set up by the EU, there are many measures taken to make Sweden more Energy efficient. In the housing and real estate sector, an installation of an exhaust air heat pump that reuses the heat in the exhaust air in order to lower the amount of acquired energy, is an example of such an action. The recovered energy can then be used for heating of radiators and tap water. This report aims to evaluate and compare three different systems using exhaust air heat pumps regarding COP, degree of coverage and cost savings. This study was delimited to only account for apartment buildings.The theory chapter describes the different conditions and factors that affect a building?s energy balance.

Energikartläggning av Försäkringskassans lokaler : rekommendationer för ett fortsatt energieffektiviseringsarbete

With new energy directives in place, the Swedish Social Service (SSS) stands beforethe challenge how to reduce the energy demand in its locales. It is a complex matter,as the locales are rented from various property owners and it becomes a question ofhow to reduce the operational electricity and influence the property owners to workmore with energy efficiency. This thesis takes a balanced research approach in threeparts. Firstly a qualitative part in form of interviews with personnel at the SSS and itsproperty owners, secondly a quantitative part of descriptive nature in form of energystatistics and thirdly a literature review of Energy Management (EM) Supply ChainManagement(SCM), Green Supply Chain Management(GSCM) and EnviromentalPerformance Indicators (EPI). This in order to be able to give normativerecommendations of how the SSS should act to reduce its energy consumption in itslocales and provide new insights on how EM, SCM, GSCM and EPI can be applied ineffect.

Framtidens energilagring : en studie av befintliga samt potentiella metoder fo?r lagring av fo?rnybar el pa? ett ha?llbart sa?tt

In today?s society there is an increasing demand for renewable energy sources such as sun and wind power. These sources are intermittent, and energy storage is therefore needed to ensure a constant power supply. This report compares pumped hydro energy storage (PHES), compressed air energy storage (CAES), flywheels, batteries, super magnetic energy storage (SMES) and hydrogen energy storage.The opportunities for further development are limited for PHES and CAES in comparison with the other technologies. Lithium-ion batteries and hydrogen energy storage are considered to have the most potential in the future.

Konsumentvänlig Energibesparingsmodell : Ett verktyg som hjälper småhusägare att sänka sina energikostnader

Energy awareness is growing among the Swedish population and a one­?to­?two-family dwelling can save energy. The purpose of this paper is to design a tool that helps these home owners reduce their energy costs.The paper develops a model that gives them an indication of how much energy they can save. For the majority of homeowners, the next step in the quest to reduce theirs is most likely an energy audit. Therefore, information to help home owners to get a good energy audit performed is included in the model.A prototype running the operating system iOS is created and validated against existing models, as well as an energy audit. .

Energieffektiv Linjesjöfart Till Och Från Gotland

The ferry traffic to Gotland is essential for the island?s ability to live and develop. Yearly, it transports 1,6 million passengers, 500 000 personal vehicles and 750 000 lane meters of freight with four Ro-Pax ferries. The traffic is controlled and subsidized by the Swedish government since 1971 in order to guarantee the inhabitants and industry of Gotland a satisfactory transportation service. As a consequence of the past decades increased traffic quality, mainly due to a decrease in crossing times, the traffic?s environmental impact and costs has also increased.The Master Thesis proposes a new Energy efficient traffic arrangement that satisfies the users? preferences in the same extent as today.

En energiutredning och miljöklassning av Hemsta 12:16

The purpose of this study was to implement an energy analysis and environmental evaluation of the property Hemsta 12:16 in Gävle. Based on two different methods, Energy Balance calculation and Environmental Building, the result of the property's energy use, energy performance and environmental impacts are presented. Except that, measures to reduce final energy consumption are presented.      The proposed measures can reduce energy usage by 100 400 kWh / year, which represents a decrease of 18% of the present energy usage. This would represent a total savings of 63 000 SEK per year. In addition, the environmental performance is improved by adopting the suggested measures..

Nollenergihus i Borlänge : Är det möjligt med biomassa, solenergi och vindkraft?

This report is of technical character and treats how to plan a small building in Borlänge, Sweden.The technical components that have been treated in the report are the construction, foundation,installations and thermic abilities of the house. In addition to planning this house the report alsocontains a part that deepens in net zero energy buildings. The purpose of the report is toinvestigate if the house in Borlänge can be constructed to meet net zero energy buildingdemands.Energy efficient houses such as passive- and net zero energy houses are showing more frequenton the market in Sweden. Ongoing climate changes and growing consciousness about theenvironment in society have contributed to that the environment is a well discussed topic. Toconsume small amounts of energy and at the same time produce local energy is thereforesomething that lies in the future and future houses.

Solenergi och värmelagring i kvarteret Lagern

Humanity stands before a huge challenge to lower its emissions of carbon dioxide and its use of energy at the same time as the global population is rising and the developing countries are being industrialized. A lot of newly built buildings are due to this challenge, designed to be more Energy efficient but also use renewable energy resources instead of pollutant fossil fuels .Solar energy is one of the purest forms of energy that exists in abundant amounts, which is why it is most likely that it could come to play a major part in the future energy market. The main purpose of this report is to investigate the possibility to implement a sustainable energy system with solar thermal heat and  heat storage as main sources of energy in the neighborhood ?kvarteret Lagern?, which is the area where the old football stadium ?Rasunda Stadion? was located. New developments within different heat storage techniques have opened up new approaches to enable buildings an all year round heat supply from solar energy. This report will focus on heat storage in boreholes. At the present here is only a preliminary plan of how the neighborhood is supposed to be designed.

Power supply monitoring for wireless sensor platforms

Most of the portable electronic devices use a battery as a primary power source. Nowadays, when the applications are becoming smaller and smaller and more power efficient, the designer needs to concentrate more on reducing power consumption, using secondary power sources and introducing power storage devices. Multiple power source availability and a power storage device on the board will make the applications much more useful and efficient in everyday use. This thesis proposes a power supply unit (PSU) for wireless sensor platforms which is capable of supplying a sensor node with energy from multiple sources, as well as status information from the PSU. Present power storage devices, like electric double-layer capacitors (EDLCs) and batteries, have become more and more common as their characteristics have developed.

Analys av hur byggnadens höjd påverkar energiförbrukningen i flerbostads- och kontorshus

This diploma work has been carried out in collaboration with the building contractor Sh Bygg Fastighetsutveckling AB in Uppsala with the intention to investigate how the height of a building affects various energy aspects such as transmission losses, infiltration, and the specific energy usage. Three different reference objects have been studied. The reference objects have been simulated for four different heights in the calculation program VIP-Energy.The results show that an increase in floor number can lead to both advantages and disadvantages. As the number of floors increases, transmission losses per square meter floor area decreases. However, as the height of the building increases, the reduction rate decreases.

<- Föregående sida 5 Nästa sida ->