Sökresultat:
2676 Uppsatser om Energy efficient ventilation - Sida 21 av 179
Low Temperature Waste Heat Solutions : with proposals for energy technological actions based on Scania?s building 64
The report comprises two separate parts:part 1: Temperature needs for district heating in the paint shop for axles in building 210part 2: Energy and low temperature waste heat solutions in heating and cooling systems for building 64 with surroundingsThe paint shop for axles in part 1 has air quality requirements in places for coating of axles. Toachieve desired air properties there are different process ventilation systems, which consist ofventilation coils for heating and cooling, plus air humidifier. The ventilations coils for heating usedistrict heating. Today the ventilation coils use water of 100°C to achieve necessary air demands inthe coating boxes. This part of the report investigates whether the existing system would achievethe air requirements with a water temperature of 75°C instead of 100°C in the ventilation coilsduring the coldest parts of the year.
Stålfiberarmerad betong - En ekonomisk jämförelse
This report is a study in voltagelevel in connection with regeneration of brake energy from the tramtype M31 in Gothenburg.In the act of braking, the tram M31 uses electrical braking where the electrical motors generates energy and if possible send it back to the overheadline, where other trams in the nearby can use this regenerated energy for its own driving force. In cases where no other energyconsumers are located in the same section, there is a resistance witch task is to convert this energy into heat. The regulation of this resistance appears to cause an increase in the voltagelevel into far too high levels.Investigations of the trams regulationequipment and its construction have been done. Further have measurements on the overheadline been performed in order to map the voltagevariations during a longer period of time.The result have been showing that the voltagelevel during regeneration often is as high as 880V-920V, more extreme values have not been observed in a large scale. The values are especially high compared to the nominal voltagelevel.
Nya inslag i bostadspolitiken konsekvenser för Helsingborg
This report is a study in voltagelevel in connection with regeneration of brake energy from the tramtype M31 in Gothenburg.In the act of braking, the tram M31 uses electrical braking where the electrical motors generates energy and if possible send it back to the overheadline, where other trams in the nearby can use this regenerated energy for its own driving force. In cases where no other energyconsumers are located in the same section, there is a resistance witch task is to convert this energy into heat. The regulation of this resistance appears to cause an increase in the voltagelevel into far too high levels.Investigations of the trams regulationequipment and its construction have been done. Further have measurements on the overheadline been performed in order to map the voltagevariations during a longer period of time.The result have been showing that the voltagelevel during regeneration often is as high as 880V-920V, more extreme values have not been observed in a large scale. The values are especially high compared to the nominal voltagelevel.
Utveckling av en metod för avvikelsehantering i byggföretag
This report is a study in voltagelevel in connection with regeneration of brake energy from the tramtype M31 in Gothenburg.In the act of braking, the tram M31 uses electrical braking where the electrical motors generates energy and if possible send it back to the overheadline, where other trams in the nearby can use this regenerated energy for its own driving force. In cases where no other energyconsumers are located in the same section, there is a resistance witch task is to convert this energy into heat. The regulation of this resistance appears to cause an increase in the voltagelevel into far too high levels.Investigations of the trams regulationequipment and its construction have been done. Further have measurements on the overheadline been performed in order to map the voltagevariations during a longer period of time.The result have been showing that the voltagelevel during regeneration often is as high as 880V-920V, more extreme values have not been observed in a large scale. The values are especially high compared to the nominal voltagelevel.
Att övervinna barriärer för kunskapsåterföring - En fallstudie av NCC
This report is a study in voltagelevel in connection with regeneration of brake energy from the tramtype M31 in Gothenburg.In the act of braking, the tram M31 uses electrical braking where the electrical motors generates energy and if possible send it back to the overheadline, where other trams in the nearby can use this regenerated energy for its own driving force. In cases where no other energyconsumers are located in the same section, there is a resistance witch task is to convert this energy into heat. The regulation of this resistance appears to cause an increase in the voltagelevel into far too high levels.Investigations of the trams regulationequipment and its construction have been done. Further have measurements on the overheadline been performed in order to map the voltagevariations during a longer period of time.The result have been showing that the voltagelevel during regeneration often is as high as 880V-920V, more extreme values have not been observed in a large scale. The values are especially high compared to the nominal voltagelevel.
Framtidens byggarbetsplats. Organisation och Kompetens
This report is a study in voltagelevel in connection with regeneration of brake energy from the tramtype M31 in Gothenburg.In the act of braking, the tram M31 uses electrical braking where the electrical motors generates energy and if possible send it back to the overheadline, where other trams in the nearby can use this regenerated energy for its own driving force. In cases where no other energyconsumers are located in the same section, there is a resistance witch task is to convert this energy into heat. The regulation of this resistance appears to cause an increase in the voltagelevel into far too high levels.Investigations of the trams regulationequipment and its construction have been done. Further have measurements on the overheadline been performed in order to map the voltagevariations during a longer period of time.The result have been showing that the voltagelevel during regeneration often is as high as 880V-920V, more extreme values have not been observed in a large scale. The values are especially high compared to the nominal voltagelevel.
BIM i produktionen vid väg- och anläggningsprojekt
This bachelor thesis has the purpose to visualize and document the air movementsprovided by different ventilation principles in an operating theatre. The visualizationwill be made as simple as possible in a physical model. The model and thedocumentation should be able to use in educational purposes.The study is based on the two most common systems for airflow, currently used inoperating theatres. The first principle is displacement ventilation in which the air issupplied at low velocity along the floor. The second principle is vertical parallel laminarairflow in which the air is compressed like a piston from ceiling to the floor.A review of literature resulted in the choice of size, design, and scale factor for themodel, as well as choices of ventilation principles and airflows.
Energieffektivisering i ett verkstadsföretag : En analys av energibesparande åtgärder samt uppvärmnings- och kylsystems driftkostnader och koldioxidutsläpp
The energy use in a workshop company has been examined in this work in order to find areas for energy efficiency improvement. The combined oil and electricity heating in the company were compared with other alternative heating systems including cooling of the premises in following combinations:Ground source heat pump for heating and coolingDistrict heating and absorption coolingDistrict heating and low temperate surface water coolingEnergy use, operation costs and carbon dioxide emissions were calculated for the current heating systems and the three alternatives including cooling. The ground source heat pump for heating and cooling decreases bought energy with 34 MWh annually compared to current heating only. The district heating and low temperate surface water cooling has the largest reduction of operation cost and carbon dioxide. The operation cost decreases with 42 kSEK and the carbon dioxide with 43 metric ton CO2 annually.
Är det lönsamt att ta hänsyn till temperatursvängningar? : En fallstudie om prognostisering på Karlstads Energi
Being able to predict the future had been an invaluable competitive advantage for any corporation. Forecasting is a vital part of any business, hence a good forecast allows enterprises to invest in a beneficial way. However, there are several ways to prepare forecasts and the forecast methodology can vary. An industry that is dependent on forecasts is the energy industry. By predicting consumers' energy consumption, Swedish energy companies can hedge on the Nordic power market Nord Pool.
Passivhus - lönsamt eller ej? : En jämförelse mellan ett passivhus och ett konventionellt hus
As a result of increased energy prices more and more energy-efficient homes are coveted. An energy-efficient alternative is passive houses, which is characterized by an extremely well insulated building envelope that recovers the heat without the use of radiators or under floor heating. But a passive house requires a higher investment cost than a conventional building project, since it will require more construction materials, training of construction workers, greater land area, and long construction period. But the lower operating cost expects to pay back the higher cost of investment. We therefore question how profitable a passive house is in relation to houses built according to modern conventional building techniques.The aim of our study is to investigate the viability of passive houses compared to conventional houses.
Fuktrisker i kallvindsutrymmen - problem och förbättringsmetoder
This report has a dual focus. The first goal was to increase the knowledge of how the use of electricity in a residential building is distributed. Electricity in residential buildings is used for lighting in common areas, elevators, pumps and many other appliances. The electricity used for these different parts is to a great extent unknown. A few studies have been carried out and the result of these is referred to in this report.By means of measurements and approximations the use of electricity for various appliances became known.
Fastighetsel och belysning i flerbostadshus : inventering, mätning och effektivisering
This report has a dual focus. The first goal was to increase the knowledge of how the use of electricity in a residential building is distributed. Electricity in residential buildings is used for lighting in common areas, elevators, pumps and many other appliances. The electricity used for these different parts is to a great extent unknown. A few studies have been carried out and the result of these is referred to in this report.By means of measurements and approximations the use of electricity for various appliances became known.
Ständiga förbättringar inom kundserviceavdelningen på IKEA Bäckebol
This bachelor thesis has the purpose to visualize and document the air movementsprovided by different ventilation principles in an operating theatre. The visualizationwill be made as simple as possible in a physical model. The model and thedocumentation should be able to use in educational purposes.The study is based on the two most common systems for airflow, currently used inoperating theatres. The first principle is displacement ventilation in which the air issupplied at low velocity along the floor. The second principle is vertical parallel laminarairflow in which the air is compressed like a piston from ceiling to the floor.A review of literature resulted in the choice of size, design, and scale factor for themodel, as well as choices of ventilation principles and airflows.
Luftföring i operationsrum. Visualisering av olika luftföringsprinciper i modellskala.
This bachelor thesis has the purpose to visualize and document the air movementsprovided by different ventilation principles in an operating theatre. The visualizationwill be made as simple as possible in a physical model. The model and thedocumentation should be able to use in educational purposes.The study is based on the two most common systems for airflow, currently used inoperating theatres. The first principle is displacement ventilation in which the air issupplied at low velocity along the floor. The second principle is vertical parallel laminarairflow in which the air is compressed like a piston from ceiling to the floor.A review of literature resulted in the choice of size, design, and scale factor for themodel, as well as choices of ventilation principles and airflows.
Trygghet ur ett boendeperspektiv
Vid projektering idag ställs konstruktören ofta inför valet att projektera för antingen ventilation med konstanta flöden, eller med variabla flöden. Vidare kan även flödena varieras manuellt eller automatiskt. Det konstruktören måste ta hänsyn till är investeringskostnaden, men även potentiella energi- samt kostnadsbesparingar över tid. Många gånger är det svårt att veta hur energianvändningen påverkas av de olika systemvalen varför det är svårt att välja det mest optimala systemet.Detta arbete undersöker livscykelkostnaden, LCC, med nuvärdeskostnaden på en skola i Uppsala med tre olika system, antingen konstant ventilationsflöde, CAV med timer, manuellt styrd variabel ventilation, VAV, eller automatisk VAV med styrning på temperatur och CO2. Huvudanledningen till det är att skolor består av en mängd olika klassrum och lokaler som inte alltid används under skoltiden, risken finns alltså att skolan överventileras med ett traditionellt CAV.