Sök:

Sökresultat:

2676 Uppsatser om Energy efficient ventilation - Sida 12 av 179

Lufttäta byggnader

The viscosity of air buildings is a hot topic within the construction performers, which the industry feel they have too little knowledge about. This study is mainly aimed against air density in apartment buildings and airflow measurement. The study consists of a theoretical reference, educational visit, interviews and a survey conducted among construction workers at Magistratshagen in Linkoping.Earlier requirement in terms of air leakage through the climate screen was removed and today there are only energy requirement for a dwelling in Boverkets Building Regulations. The difference between a passive and a typical air tight construction is that the passive house have a maximum requirement of 0.3 l /s m2 of air leakage through the building climate screen. The requirement imposed on passive houses is to minimize the supply of power and energy for heating the building.Air tight constructions have heavy demands on the performance and accuracy of everyone involved with the project. The client must specify their requirements and also be prepared to pay for any additional costs. The architect and building planners have to design the building with regard to air tightness. Finally, the construction workers are required to do a careful work in order to get all the connections in the building air tight.The study suggests that an air tight building is a closed system where no forced ventilation exists. There are no reasons not to build too tight as long as there is a functioning ventilation. In this study the authors ask themselves how an air tight building changes over time. No theoretical information has been found on these changes, but the respondents assume that air density decreases with time. The deterioration is mainly assumed to be caused by construction materials changes over time. The study shows that construction workers knowledge of air tight construction is mixed, which they themselves admit in the survey..

APS - Akustiskt positioneringssystem

The objective of this work was to evaluate and implement a number of energy saving functions for a specific embedded system. The functions were then grouped into a number of energy levels with known properties in terms of functionality, energy consumption, and transition time between the levels.The embedded system consisted of an AT91 ARM9 processor, GSM/GPRS modem, display, Ethernet and other peripheral units. Some energy saving methods that were considered were suspend to RAM, suspend to disk, frequency scaling, and methods for saving energy in the modem, Ethernet, USB and display backlight. The functions were grouped into levels and an interface was specified for controlling the energy level.It proved possible to get known properties within the defined energy levels, even though the paritioning of functions into these levels proved to be sub-optimal in a typical application usage scenario because it was designed for mainly energy consumption, not usage.The final result is a number of energy saving functions grouped into levels, which are controllable via an application interface. Each of the levels have a known energy consumption in both loaded and un-loaded mode..

Användning av fjärravläst mätdata för framtagning av byggnaders effektsignatur.

How to use automatically read data to create a method that visually describes how energy is used in a building, the so called energy signature..

Solenergisystem i Kista Galleria

Solar energy is the one most talked about among energy sources due to its huge potential amongst renewable energy technologies. A greater use of the solar energy may be the solution to today's climate threats. Normally there are two different types of solar technologies, solar cells and solar thermal collectors. Solar cells convert solar energy in to electricity whilst solar thermal collectors convert solar energy into heat, which can be used to heat hot water for households. This goal of this study has been to investigate the possibility of implementing solar energy into the energy system of Kista Galleria, one of Sweden's foremost venues.

Energisystemanalys av ABB AB LV Motors

With a larger awareness of the climate changes and increasing electricity prices, energy efficiency measures in the industry have become more common. By rationalize the activity and by the same time decrease the emission of greenhouse gases the company can both save money and reduce negative environmental impact. For the Swedish industries the electricity price have traditional been relative low, which has resulted in a considerable larger usage than other European countries. By a deregulation of the European electricity market the electricity price will level off between the countries, which will cause a higher electricity price in Sweden than we are use to. To prevent that the Swedish industry don?t lose competitiveness against the other European countries, it will require energy efficiency activities in all different forms.ABB Sweden has decided to decrease their total energy usage with five percent in two years.

Utveckling av försäljnings- och leveransmodell

The objective of this work was to evaluate and implement a number of energy saving functions for a specific embedded system. The functions were then grouped into a number of energy levels with known properties in terms of functionality, energy consumption, and transition time between the levels.The embedded system consisted of an AT91 ARM9 processor, GSM/GPRS modem, display, Ethernet and other peripheral units. Some energy saving methods that were considered were suspend to RAM, suspend to disk, frequency scaling, and methods for saving energy in the modem, Ethernet, USB and display backlight. The functions were grouped into levels and an interface was specified for controlling the energy level.It proved possible to get known properties within the defined energy levels, even though the paritioning of functions into these levels proved to be sub-optimal in a typical application usage scenario because it was designed for mainly energy consumption, not usage.The final result is a number of energy saving functions grouped into levels, which are controllable via an application interface. Each of the levels have a known energy consumption in both loaded and un-loaded mode..

Osäkerheter vid brandteknisk dimensionering av ventilationssystem

This masters thesis deals with smoke spread via ventilation systems. One aim of the thesis is to investigate and explain the differences in efforts to prevent smoke spread via ventilation systems in different countries. A second aim of this thesis is to investigate how frequently occurring smoke spread via ventilation systems in Swedish buildings are. A third aim is to investigate how uncertainties in input variables to smoke spread calculations will affect the result of calculation. To be able to do this the most important input variables are identified and analysed.

Kartläggning av energianvändning under byggfasen vid nyproduktion av flerbostadshus

The energy consumption in the sectors of residential and public buildings is 40 % of the total energy consumption in Sweden. The main part, 85 %, of the energy use in these sectors is for operation of the buildings. The rest is used in the building process. When energy-efficiency measures are taken the energy use during the operation time decreases and the fraction of energy consumption during the building time increases. This project is carried out in cooperation with JM AB and concerns the energy use during the building time of production of blocks of flats at the building site.The main part of the electricity that is used during the production of apartment buildings goes into the heating of portacabins and illumination of the building during the construction phase.

Energideklarationen : Uppfyller energideklarationen sitt syfte?

The Energy Performance Certification in Sweden was developed as a tool to achieve the Government's target to reduce Sweden's energy consumption by 20 percent by 2020. The Energy Performance Certificate has previously received some criticism for not fulfilling its purpose. Questions that formed the basis for this report is how the energy performance certification provides support to buyers of single-family houses and if the energy performance improved in terms of reliability. The report begins with a background description that describes how the energy declaration works and some of the findings of previous evaluations and surveys. A survey to investigate the broker's position to energy performance have been conducted as well as interviews with buyers and sellers of houses. An investigation whether the energy performance can vary between different calculation programs, depending on various assumptions made by the energy declarant, has been made.Brokers and sellers have proved negative attitudes towards energy performance, particularly brokers.

Uppvärmningssystem : Ekonomi, miljö och drift

This bachelor thesis aims at investigate how a specified house can optimize its energy consumption.Today the house often stands for the major part of the energy consumption in a consumers? life,whereas an energy optimization creates economic as well as environmental advantages. It is importantto make old houses more energy efficient, but putting high energy demands on new houses could beargued to be more important. The installations functions as both the heart and brain in a house, thusmaking it important to energy optimize these. Since the background describes the importance ofenergy efficiency and optimization in a house, the focus area of this report will be an investigation ofdifferent types of heating systems in order to be able to choose the one most suited for the house.Aspects considered when choosing the heating system was how economic the system is both inservice- and investment costs and how environmental and operational friendly the system is.Through literature reviews there were sufficient information gathered that served as a foundation whencomparing and choosing between the four systems - district heating, pellet-fired boiler, geothermalheating and solar heating.

Avvikelser i energiprestanda

Calculated and measured energy in residential buildings is going to differ. The reason to this may be due to many factors. In this study there is a study on how these factors affect the energy use in a building. To get an insight in what defines energy, there is first a description of energy supply both worldwide and used in Sweden, followed by a description of the energy balance. In this study energy will be studied in residential buildings only.

Energieffektivisering i sambandmed renovering : ? Analysmodell för energibesparande åtgärderutifrån ett företagsekonomiskt perspektiv

Rising energy prices and higher energy demands have led to an increased focus on energy efficiency, in particular in the real estate business, where high potential for energy savings exists. Within the next few years, buildings that were constructed in the sixties and seventies will be in need of renovation. One of the challenges of these renovations will be to improve energy efficiency. A real estate company that is facing this challenge is Uppsalahem AB, based in the city of Uppsala, Sweden. This study focused on analyzing energy efficiency measures when renovating old buildings.

Larynxmask : - en metod för att möjliggöra fri luftväg och adekvat ventilation

Ofri luftväg kan uppstå på grund av bakåtfallen tunga hos den medvetslösa patienten eller om luftvägen blir tilltäppt av sekret, blod, maginnehåll eller främmande kropp. Att kunna säkerställa fri luftväg hos den medvetandesänkta patienten är en kompetens som varje anestesisjuksköterska måste behärska för att kunna säkerställa adekvat ventilation. Syftet med studien var att beskriva om larynxmask (LMA) är en patientsäker metod för att skapa fri luftväg och upprätthålla adekvat ventilation. Studien genomfördes som en litteraturstudie där 19 vetenskapliga artiklar analyserades. Resultatet av de granskade artiklarna gav följande fem teman; LMA är en säker metod för att skapa fri luftväg, LMA är en säker metod för att upprätthålla adekvat ventilation, personalens kompetens vid användning av LMA, aspirationsrisk vid användning av LMA med undertema LMA vid övervikt samt LMA vid elektiva- och akuta situationer.

Opera i Stockholm, Galärvarvet

Suggestion for a new operahouse in stockholm, förslag på nytt operahus i stockholm. Stockholmsoperan..

Energiaspekter på gestaltning : fallstudie Energihuset i Uppsala

This thesis has been carried out at the Department of Urban and Rural Development at SLU Ultuna during the spring semester 2009. The topic of the paper is how energy consumption can be influenced through design and if the conditions for good design decreases when solutions based on energy efficiency are used. The report is divided into one literature study and one part where energy efficient solutions are used in a design. The thesis work has its origin in a project called "Energihus i Uppsala." The planned building will be a center for energy research in Uppsala. The project aims to demonstrate to the public what is currently happening in research related to energy.

<- Föregående sida 12 Nästa sida ->