Förbättrad tillgång till referensmaterial vid röntgentolkning
This thesis includes an energy survey of the Herrgården pre-school, which has a modern heating- and ventilation system, and a comparison with Östers pre-school which has an older system. An energy survey of Östers pre-school has already been done by a group of three students and all the calculations and values have been collected from that survey. As of today, both pre-schools are heated thru district heating. It will be much easier to make smart and feasible energy-saving-measures by first conducting the energy survey.Herrgården pre-school in Gävle houses 81 children, therteen teachers, one cleaner and one cook. It was finished in the middle of 2009 and the staff has been very pleased with the in-door climate.
Utvärdering av magnetiska alternativ till optisk scanning
This thesis includes an energy survey of the Herrgården pre-school, which has a modern heating- and ventilation system, and a comparison with Östers pre-school which has an older system. An energy survey of Östers pre-school has already been done by a group of three students and all the calculations and values have been collected from that survey. As of today, both pre-schools are heated thru district heating. It will be much easier to make smart and feasible energy-saving-measures by first conducting the energy survey.Herrgården pre-school in Gävle houses 81 children, therteen teachers, one cleaner and one cook. It was finished in the middle of 2009 and the staff has been very pleased with the in-door climate.
APS - Akustiskt positioneringssystem
The objective of this work was to evaluate and implement a number of energy saving functions for a specific embedded system. The functions were then grouped into a number of energy levels with known properties in terms of functionality, energy consumption, and transition time between the levels.The embedded system consisted of an AT91 ARM9 processor, GSM/GPRS modem, display, Ethernet and other peripheral units. Some energy saving methods that were considered were suspend to RAM, suspend to disk, frequency scaling, and methods for saving energy in the modem, Ethernet, USB and display backlight. The functions were grouped into levels and an interface was specified for controlling the energy level.It proved possible to get known properties within the defined energy levels, even though the paritioning of functions into these levels proved to be sub-optimal in a typical application usage scenario because it was designed for mainly energy consumption, not usage.The final result is a number of energy saving functions grouped into levels, which are controllable via an application interface. Each of the levels have a known energy consumption in both loaded and un-loaded mode..
Användning av fjärravläst mätdata för framtagning av byggnaders effektsignatur.
How to use automatically read data to create a method that visually describes how energy is used in a building, the so called energy signature..
Solenergisystem i Kista Galleria
Solar energy is the one most talked about among energy sources due to its huge potential amongst renewable energy technologies. A greater use of the solar energy may be the solution to today's climate threats. Normally there are two different types of solar technologies, solar cells and solar thermal collectors. Solar cells convert solar energy in to electricity whilst solar thermal collectors convert solar energy into heat, which can be used to heat hot water for households. This goal of this study has been to investigate the possibility of implementing solar energy into the energy system of Kista Galleria, one of Sweden's foremost venues.
Prestandaförändringen hos en bergvärmeanläggning efter fem års drifttid
The aim of this report was to do a case study at a geothermal heating system which has been in operation for about 5 years, and study if its performance has changed during this period of time. A literature study about the processes involved was also done in purpose of background knowledge.The tenant-owner?s association Duvan at Petterslundsgatan in Uppsala installed year 1999-2000 a geothermal heating system. The purpose of this installation was that they hoped it would lead to a smaller usage of district heating which would lead to a reduction of the heating expenses for their buildings. The geothermal heating system consists of 19 energy wells and 4 geothermal heat pumps, and it is one of the first systems of that size in the region of Uppsala.
Det energisnåla isoleringsmaterialet
This bachelor essay is divided into two parts, the first being a construction of a single-familyhouse and the second an in-depth study of five different isolation materials, analysed from anenergy perspective.The first part, the construction of the single-family house, has been created from knowledgeacquired during three years of studying at KTH Royal institute of Technology in Stockholm, inthe program Architecture and the Built Environment. The constructed house is a one-floorhouse of 137m2with façade plaster, situated in Borlänge, Sweden. The house has a wooden framewhich is built on a on sight cast concrete foundation, on the ground. The house?s roof is a gableroof, which has an angle of 24 degrees.
Underlag för solcellsproducerad el i Stockholm : Potential och klimatpåverkan
The City of Stockholm has decided to invest in renewable energy and especially in photovoltaics. The objective of this thesis is to investigate the photovoltaic potential on roof areas that the city possesses and to further investigate some buildings of the Property Management Department. The thesis also compares some existing photovoltaic plants with the solar irradiance map which shows available roof area on each building in Stockholm. The report ends with a literature study about the climate impact and greenhouse gas emissions of photovoltaic.The total available roof area suitable for photovoltaic plants is estimated to 700 000 m2, with a potential electricity production of 110 GWh per year. This corresponds to 17 % of the City of Stockholm?s yearly electricity consumption.
Utveckling av försäljnings- och leveransmodell
The objective of this work was to evaluate and implement a number of energy saving functions for a specific embedded system. The functions were then grouped into a number of energy levels with known properties in terms of functionality, energy consumption, and transition time between the levels.The embedded system consisted of an AT91 ARM9 processor, GSM/GPRS modem, display, Ethernet and other peripheral units. Some energy saving methods that were considered were suspend to RAM, suspend to disk, frequency scaling, and methods for saving energy in the modem, Ethernet, USB and display backlight. The functions were grouped into levels and an interface was specified for controlling the energy level.It proved possible to get known properties within the defined energy levels, even though the paritioning of functions into these levels proved to be sub-optimal in a typical application usage scenario because it was designed for mainly energy consumption, not usage.The final result is a number of energy saving functions grouped into levels, which are controllable via an application interface. Each of the levels have a known energy consumption in both loaded and un-loaded mode..
Gotlands solelpotential
The aim of this thesis is to investigate the electric solar potential on the Swedish island Gotland. The Gotlandic habitations have been divided into four house categories. For each category energy demand, roof area, geographic orientation androof tilt have been decided. Solar radiation data have been collected from the Swedish solar radiation model STRÅNG (STRÅNG, 2012).The buildings characteristics and the solar radiation have been used as input values in common solar formulas, the solar potential for each building category have been summed up to a total electric solar potential for the region.The electric solar potential on Gotland was calculated to 242 GWh/year with solar data from 2010. Gotlands largest city, Visby, is marked as cultural heritage by UNESCO (UNESCO, 2012).
Höghus : En alternativ lösning på vår snabba stadsexpansion
Uppsala like many other Swedish cities is affected by heavy housing shortage, in terms of too few existing flats and residents within the city limits. Every semester thousands of new students are facing the same problems of finding themselves adequate accommodation. The waiting lists for flats and student-dorms are getting longer for each year, and the situation is just getting worse. Simultaneously, Uppsala?s ambition is to increase its population and expand as a Swedish metropolitan, according to the Swedish governmental environment goals. This paper investigates and analyses the possibilities of expanding a city?s population by building high-rise buildings.
Energideklarationen : Uppfyller energideklarationen sitt syfte?
The Energy Performance Certification in Sweden was developed as a tool to achieve the Government's target to reduce Sweden's energy consumption by 20 percent by 2020. The Energy Performance Certificate has previously received some criticism for not fulfilling its purpose. Questions that formed the basis for this report is how the energy performance certification provides support to buyers of single-family houses and if the energy performance improved in terms of reliability. The report begins with a background description that describes how the energy declaration works and some of the findings of previous evaluations and surveys. A survey to investigate the broker's position to energy performance have been conducted as well as interviews with buyers and sellers of houses. An investigation whether the energy performance can vary between different calculation programs, depending on various assumptions made by the energy declarant, has been made.Brokers and sellers have proved negative attitudes towards energy performance, particularly brokers.
Uppvärmningssystem : Ekonomi, miljö och drift
This bachelor thesis aims at investigate how a specified house can optimize its energy consumption.Today the house often stands for the major part of the energy consumption in a consumers? life,whereas an energy optimization creates economic as well as environmental advantages. It is importantto make old houses more energy efficient, but putting high energy demands on new houses could beargued to be more important. The installations functions as both the heart and brain in a house, thusmaking it important to energy optimize these. Since the background describes the importance ofenergy efficiency and optimization in a house, the focus area of this report will be an investigation ofdifferent types of heating systems in order to be able to choose the one most suited for the house.Aspects considered when choosing the heating system was how economic the system is both inservice- and investment costs and how environmental and operational friendly the system is.Through literature reviews there were sufficient information gathered that served as a foundation whencomparing and choosing between the four systems - district heating, pellet-fired boiler, geothermalheating and solar heating.
Förskolor med passivhusteknik : En utredning av passiva förskolor
As a result of directives from EU, with the ambition to reach environmetal goals, The German organisation Passivhaus Institut has defined a passive house. A passive house is a building that is very energy efficient and makes a small impact on the environment. The energy from the inhabitants as well as the appliances & fixtures in the building should equal the energy that is required to heat the building. A Swedish version of the passive house definition has been defined, taking into account the climate conditions and the difference in building regulations.This thesis is a request from Skanska on how it can improve and develop an ongoing passive house project, involving an infant school. The intention of this thesis is to identify difficulties & display potential development areas for infant schools.The method of research conducted is as follows: interviews of clients, ventilation consultant, consultant for heating system and an energy calculation consultant, an inspection of the infant shcool in process, investigation of completed infant schools and a study of relevant literature.From this research it was found that it is difficult for infant schools to pass the criteria for passive houses. The conclusion of this thesis provide several guidelines on how to improve the outcome of existing projects & the steps needed to be taken for future development in this area..
Energiaspekter på gestaltning : fallstudie Energihuset i Uppsala
This thesis has been carried out at the Department of Urban and Rural Development at SLU Ultuna during the spring semester 2009. The topic of the paper is how energy consumption can be influenced through design and if the conditions for good design decreases when solutions based on energy efficiency are used. The report is divided into one literature study and one part where energy efficient solutions are used in a design. The thesis work has its origin in a project called "Energihus i Uppsala." The planned building will be a center for energy research in Uppsala. The project aims to demonstrate to the public what is currently happening in research related to energy.