Sök:

Sökresultat:

3339 Uppsatser om District Heating Production - Sida 2 av 223

Lantbruket som energiproducent : tekniska, ekonomiska och miljömässiga förutsättningar för fjärrvärmeproduktion med lokalt skogsbränsle

A third party access to district heating networks has been proposed in Sweden, to increase the competition on the district heating market. Such third party access could create opportunities for the agricultural sector as an energy producer. This study describes the technical, economical and environmental prerequisites for a farmer cluster to build and run a heating plant, fueled with local wood fuel. The heating plant in the described scenario is 8 MW and will supply a village of 1000 houses, and is fueled with wood chips exclusively. Supplying a heating plant with fuel puts high demands on the logistics, since there need to be a continuous flow of fuel. In the scenario, wood residues from felling and thinning is stored in stacks in the forest, and a few times a year chipped and transported to a storage area at the heating plant. In the study, an estimation of the profitability has been made by estimating the cost of the investment, personnel, operating and maintenance costs and costs for the fuel and ash handling.

Högtempererat borrhålslager för fjärrvärme

The district heating load is seasonally dependent, with a low load during periods of high ambient temperature. Thermal energy storage (TES) has the potential to shift heating loads from winter to summer, thus reducing cost and environmental impact of District Heat production. In this study, a concept of high temperature borehole thermal energy storage (HT-BTES) together with a pellet heating plant for temperature boost, is presented and evaluated by its technical limitations, its ability to supply heat, its function within the district heating system, as well as its environmental impact and economic viability in Gothenburg, Sweden, a city with access to high quantities of waste heat.The concept has proven potentially environmentally friendly and potentially profitable if its design is balanced to achieve a good enough supply temperature from the HT-BTES. The size of the heat storage, the distance between boreholes and low borehole thermal resistance are key parameters to achieve high temperature. Profitability increases if a location with lower temperature demand, as well as risk of future shortage of supply, can be met.

Utvärdering av en väggkonstruktion utan PE-folie : Med en undersökning av hårdvaxolja som diffusions-/konvektionsspärr

District heating covers around 80 % of the heating demand in apartment buildings and 10 % in single-family homes in Sweden. In the year 2010 the total input of energy to the Swedish district heating grids was about 70 TWh, which corresponds to 11 % of the total energy input to the whole energy system in the country. Through the combined production of heat and power the CHP-plants often reaches an efficiency of 90 % from energy in the fuel to produced heat and power. In order to keep the efficiency high it is important for the owners of the plant to have good knowledge about the plants performance at different operation points. Strängnäs Energi AB initiated this diploma work together with FVB Sverige ab in order to come up with a program for short term planning of the production of heat and power at the company´s CHP-plant.The work consists of three main parts.

Life Cycle Cost : Studie om LCC som verktyg att utva?rdera geoenergianla?ggningar

Life Cycle Cost, often abbreviated as LCC, is a common tool for comparing the total cost of different alternatives, such as heating and cooling methods. Common heating and cooling methods in Sweden are geothermal energy, district heating and district cooling. This report aims to evaluate how different heating and cooling methods differ from each other while being applied on three different types of buildings, using selected LCC-models. Information about the selected LCC-models wasretrieved from each separate model and its website. Reports and agencies were used as sources for information about the heating and cooling methods.

KORTSIKTIG PRODUKTIONSPLANERING I MINDRE FJÄRRVÄRMESYSTEM : En studie vid Strängnäs Energi AB

District heating covers around 80 % of the heating demand in apartment buildings and 10 % in single-family homes in Sweden. In the year 2010 the total input of energy to the Swedish district heating grids was about 70 TWh, which corresponds to 11 % of the total energy input to the whole energy system in the country. Through the combined production of heat and power the CHP-plants often reaches an efficiency of 90 % from energy in the fuel to produced heat and power. In order to keep the efficiency high it is important for the owners of the plant to have good knowledge about the plants performance at different operation points. Strängnäs Energi AB initiated this diploma work together with FVB Sverige ab in order to come up with a program for short term planning of the production of heat and power at the company´s CHP-plant.The work consists of three main parts.

Geotermisk fjärrvärme i Gunsta

Gunsta is situated about 10 km east of Uppsala. Today there are plans to establish 1000 new households in Gunsta before year 2030. The required energy for heating houses and water would be distributed via a district heating system, which also includes 200 existing residences. The annual required energy, according to this study, would be 16.2 GWh with a maximal peak effect of 6.9 MW. To meet this need, the study suggests a system with heat pumps to upgrade the 31?C water from a 1.8 kilometre deep borehole.

Kyla på Swedavia Stockholm Arlanda : Kartläggning av nuvarande fjärrkylasystem och framtida utvecklingsmöjligheter

Arlanda airport is Sweden?s largest airport. The demand for comfort cooling of the airport?s buildings is high and is mainly provided by district cooling. District cooling is based on the same principle as district heating.

Energieffektivisering i ett verkstadsföretag : En analys av energibesparande åtgärder samt uppvärmnings- och kylsystems driftkostnader och koldioxidutsläpp

The energy use in a workshop company has been examined in this work in order to find areas for energy efficiency improvement. The combined oil and electricity heating in the company were compared with other alternative heating systems including cooling of the premises in following combinations:Ground source heat pump for heating and coolingDistrict heating and absorption coolingDistrict heating and low temperate surface water coolingEnergy use, operation costs and carbon dioxide emissions were calculated for the current heating systems and the three alternatives including cooling. The ground source heat pump for heating and cooling decreases bought energy with 34 MWh annually compared to current heating only. The district heating and low temperate surface water cooling has the largest reduction of operation cost and carbon dioxide. The operation cost decreases with 42 kSEK and the carbon dioxide with 43 metric ton CO2 annually.

Fördelning av samkostnader - En studie över hur svenska energibolag fördelar samkostnader mellan el och fjärrvärme i ett kraftvärmeverk

Cost allocation ? a study of how Swedish energy companies allocate costs between electricity and district heating in a combined heat and power plant District heating is today the most utilized alternative for heating in Sweden. In a combined heat and power plant (CHP) electricity and heat are cogenerated. The environmental and economic advantages with this kind of production are high. A problem in a CHP-plant is to allocate costs between electricity and heat since both products are generated in the same process.

Uppvärmningssystem : Ekonomi, miljö och drift

This bachelor thesis aims at investigate how a specified house can optimize its energy consumption.Today the house often stands for the major part of the energy consumption in a consumers? life,whereas an energy optimization creates economic as well as environmental advantages. It is importantto make old houses more energy efficient, but putting high energy demands on new houses could beargued to be more important. The installations functions as both the heart and brain in a house, thusmaking it important to energy optimize these. Since the background describes the importance ofenergy efficiency and optimization in a house, the focus area of this report will be an investigation ofdifferent types of heating systems in order to be able to choose the one most suited for the house.Aspects considered when choosing the heating system was how economic the system is both inservice- and investment costs and how environmental and operational friendly the system is.Through literature reviews there were sufficient information gathered that served as a foundation whencomparing and choosing between the four systems - district heating, pellet-fired boiler, geothermalheating and solar heating.

Hur fungerar logistiken i produktionen på ett byggföretag?

The Work has been performed to, and in cooperation with Vetlanda Energi och teknik AB.District heating for commercial purpose started in the USA in 1877. Today the network has grown into big and complex systems, which demand maintenance and service to keep up the security of the delivery. When a district heating network expand, it becomes difficult to perform reliable calculations. For this purposes there are a few suppliers who design and deliver systems for documentation and calculation of district heating networks.Vetlanda Energi och Teknik AB is in the position where they must get a system for documentation and calculation for district heating, and therefore they need a basis to get a system. The target is to write a requirement specification that will follow the basis.The Swedish market has been inventoried, and suitable systems have been selected.

Dokumentationssystem för fjärrvärmenät

The Work has been performed to, and in cooperation with Vetlanda Energi och teknik AB.District heating for commercial purpose started in the USA in 1877. Today the network has grown into big and complex systems, which demand maintenance and service to keep up the security of the delivery. When a district heating network expand, it becomes difficult to perform reliable calculations. For this purposes there are a few suppliers who design and deliver systems for documentation and calculation of district heating networks.Vetlanda Energi och Teknik AB is in the position where they must get a system for documentation and calculation for district heating, and therefore they need a basis to get a system. The target is to write a requirement specification that will follow the basis.The Swedish market has been inventoried, and suitable systems have been selected.

Lantbrukaren som energiproducent : en fallstudie i energisatsningar inom lantbruket

The intrest and development of bioenergy and energy from renewable sources in Sweden has increased rapidly over the last few years. There are a whole lot of alternatives for those who would like to venture and invest in renewable energy production. Production of renewable energy opens up many opportunities for forestry and farming to venture a new branch of production, on basis of the primary production. Several of the new energy sources grows on farmland or in the forest. The opportunities exist in the primary products, as well as in refining and reselling, in the value chain of energy. The starting-point is the Farmer as an energyproducer. This master thesis studies the nature of farmer-own firms, who has invested in production of renewable energy.

Beräkning av värmeenergiförluster i flerbostadshus genom analys av den totala fjärrvärmeenergianvändningen :

This thesis has been carried out on behalf of IV Produkt AB and intends to set an average ratio of thermal energy losses in apartment buildings that were built during the 1960-1990. This shall be derived by analyzing the total district energy consumption that has been divided into three parts: heat energy losses (the actual heating requirements), the heating of domestic hot water and heating energy consumption for the controlled ventilation.Three different residential areas that were built during the years 1962-1966 and one that was built in 1993 has been analyzed. All residential areas are located in Växjö urban and contains between four and six apartment buildings.The analyzed objects have a mechanical exhaust ventilation systems and district heating as the heating method. No own laboratory work or experiments have been done in this thesis, the calculations have been done on the basis of parameters from VEAB, interviews with property managers, and literature studies. By calculations, we have got a result that is reported in Chapter 6.

Utveckling av lastmodell för Uppsala fjärrvärmenät

The aim of this study was to develop a load prognosis model for Uppsala district heating system to be used as a tool for heat production optimization. The methodwas to build three models for the different customer types; housing, industry andoffices and then scale them for the total system using data from Uppsala districtheating system. The heat load consists of two parts, one that is temperaturedependent and one that is dependent of the social behavior of the customers. Thetemperature part was modelled with an ARX model using an outdoor temperatureprognosis as input signal. The social behavior part was modelled using the mean ofthe social behavior from some days before and additionally by distinguishing betweenweekdays and weekends.

<- Föregående sida 2 Nästa sida ->