Sök:

Sökresultat:

6442 Uppsatser om Demand response energy markets value potential - Sida 22 av 430

Energieffektiv högtalare med trådlös kommunikation

Music today is a big part of a person's everyday life and can influence emotions as wellas initiative and motivation. This effect together with development in technology hasled to that music today is accessible and can be played from a large amount of differentkinds of products. This in turn has meant that the demand for smaller audio playbackdevices is greater than ever.The goal of this project is to develop a concept for energy-efficient speakers withwireless communication that has the ability to obtain and play high quality music. Thespeakers will use the latest available technology and at the same time, using digitalsignal processing, have a low environmental impact through high energy efficiencyand low power consumption. Parallel to this work a pilot study will be conducted tosee trends in listener preference of sound.The result achieves the goals pledged while power consumption in sleep mode is solow that they meet the demands of tomorrow.

Osäkerhet i energisimuleringar av flerbostadshus : Analys av fem nybyggnationer

Since energy simulations are used to verify that projected residential buildings will reach the current energy requirements it is important that the results are reliable.This report investigates the extent of uncertainty in energy simulations, estimates the causes of the uncertainty and its economic and environmental consequences.The method used in this report is based on three validation methods; empirical validation, analytical validation and comparative validation. The analysis was carried out for five multi-family dwellings in Uppsala with installed meters for energy measurements. One of these objects, Klockarlunden, was studied in more detail than the others.The results show that the deviations are between 10 and 29% for the studied objects, which means that the uncertainty is estimated to be at least 29%. All simulations underestimate the buildings need of energy. The simulation for Klockarlunden can predict the energy consumption to be within the range of 46-98 kWh/m2year with 90% confidence level based on the current uncertainty.

Utvärdering av inomhuslokalisering med Bluetooth Low Energy

Wireless communication is becoming more common, a relatively new technology within the area is Bluetooth Low Energy. It?s been developed to be energy efficient and in regard to compatibility. Alongside the growth of wireless technology, scientists and companies are looking for new areas of use. One of these is localization, which means to determine the position of a moving device with the use of stationary devices, an example of this would be GPS.This report means to evaluate indoor localization using Bluetooth Low Energy and was made for Combitech AB in Jönköping.

Utvärdering och åtgärdsförslag av energianvändning i kontorsbyggnad

AbstractEmbla 5 is an office building which has done a large improvement. The clients of this building has made an order of WSP and the student Anders Kempe to calculate the use of energy for the building, and after that result proposing further measures which can decrease the energy use of Embla 5.The ground for this report is when calculation of the present energy use of the building is stated. To make that information of a number of parameters such as envelope, the heating system and ventilation has been located and set in to the simulation program IDA ICE which calculate the energy use.To improve the energy use further this project has been concentrated to change the system of ventilation. Today the ventilation system is of the kind CAV (constant air volume) and the air flow is dimensioned for after recommendations from BBR and Arbetsmiljöverket in the office spaces. Consider that Embla 5  is an office building where the people only staying for 8-10 hours/day so was the ide to see how much energy saving if the air flow is reduced the time people not being in the building.

Energieffektivisering i flerbostadshus : En analys av ägarformens påverkan på arbetsprocessoch resultat

In Sweden the residential and commercial sector is a major user of energy, why the Swedish government has set a specific goal to half the energy usage in buildings by 2050, compared to 1995. The Swedish Energy Agency has therefore started the campaign ?Halvera Mera? to encourage demonstration projects that will show how to renovate in an energy efficient way, and in doing so prove that it is possible to reduce a building?s energy usage by half and still make a profit. These projects are intended to serve as good examples and give inspiration to residential owners to perform energy efficient renovations. To make sure that these projects serve their purpose, it is important to know what will inspire and what will impede a residential owner to invest in energy efficiency improvements.

Studie av värmeflöden i befintligt bostadsbestånd : Utvärdering av energieffektiva besparingsåtgärder

The purpose of this master thesis is to investigate different types of measures for making buildings more energy efficient and to estimate their profitability. The calculations were performed with the building simulation program VIP+ and the evaluation of the profitability with the life cycle cost method. Furthermore, it was examined how losses in the distribution of secondary systems of district heating can be avoided. Options to replace district heating with a local district heating system based on bio-energy have been investigated. The possibilities of achieving more efficient thermal energy consumption and production for the chosen estate were also examined.The object of the study has been a residential estate with 133 detached houses in Uppsala, built in 1974.

Tilläggsisolering - lönsamt enligt en livscykelkostnadsmodell?

It is found that the properties of the record years of 1965-1975 is leaking a lot of energy andthese properties are facing a major energy efficiency. From the energy aspect, the facade isafflicted with poor thermal insulation which is a big problem. To address this problem addinginsulation is a good alternative to reduce overall energy consumption of a building. Thewindows on these buildings are also a problem from the energy point of view. Therefore,there are many reasons considered for energy upgrading.

Konvertering från direktverkande el i kommersiella lokaler : Ekonomisk och hållbar utveckling

Buildings worldwide account for 40 % of the total energy use. Climate change is of increasing importance, but few are willing to reduce their standard of living or get a higher cost for the change. Energy efficiency of existing buildings gives the greatest benefit economically and environmentally. The real estate company Klövern AB manages 46 properties in Karlstad. Heating is the major cost of the total operating costs of real estate. Rising energy prices increase the need for Klövern AB to improve energy efficiency and to investigate alternative sources of heat.

Varför uppförs så få bostadsrätter med passivhusstandard i Sverige? : En fallstudie mellan ett passivhus- och en konventionell fastighet

Abstract Background: In 1997 the Kyoto Protocol was signed, it?s an international agreement which is aimed to reduce greenhouse gas emissions. Sweden's goal is to reduce energy using in buildings with 20 percent by 2020 and 50 percent by 2050. This is a comparison with levels from 1995 (Glad, 2006). For Sweden to be able to reach its goals, they need to construct more low-energy buildings (Åhman, Wahlström & Lundblad, 2010).

Energibalansen för ett nytt flerbostadshus i Mellansverige : Beräkningar intervjuer och analys av energikraven i Boverkets Byggregler

Abstract   This degree project comprises 30 credits, i.e. 20 weeks of work. The work mainly deals with the energy balance for a multi-family house in Västerås and the requirements for energy conservation in the Swedish building code, BBR. Calculations of the energy balance are supplemented by a number of interviews. Energy conservation in general has become more important in recent years and the subject is in line with increased public awareness. This importance and attention is explained by environmental problems in general and global warming in particular, but also by rising energy prices.

Energieffektivisering av modern tillbyggnad till äldre skola : fallstudie från Österbyskolan i Österbybruk

The Swedish government has introduced a goal to reduce the energy intensity by 20% to the year 2020. To reach this goal actions need to be taken throughout the energy sector which includes residential and commercial buildings. This thesis considers the possibility to reduce the energy usage in a building located close to Uppsala. The analyzed building is a combined office, cafeteria and entrance and was completed about half a year before this project started. Therefore the measures presented for a more energy efficient building are presented as measures for future constructions.Simulations have been made in VIP-Energy, a dynamic energy calculation program.

Projektering av ett småhus samt ekonomisk jämförelse av värmesystem

Design of a house requires knowledge of both technology and economics. Heating and ventilation shall be designed, costs are calculated and estimated and requirements must be fulfilled. Which heating system is to be elected is also a difficult choice, especially with rising energy prices as a factor.The choice of energy system is not always given, because it depends on several factors. Below is a comparison between district heating, geothermal heat pump and electric boiler from an economic standpoint. In a previous report appears district heating and geothermal heat pump as the best options.

Statuskontroll av Paradisskolans elektriska belastning

In this thesis is studied the electrical load of Paradisskolan with respect to power quality and energy consumption. The school's owner Trollhättans Tomt AB is also interested to know if they can reduce their costs by changing to smaller meter fuses. A recurring ground fault that?s been recorded from powerpanel A1A has been investigated. The school's equipped with an electrical bonding system, harmonic filters for the third harmonic currents, TN-S system from feeding transformer and groundfault monitoring.

Hållbara projekteringsverktyg : Från byggnadsinformationsmodell till simulering ? en utvärdering av Revit och Virtual Environment

This study examines the use of building modeling and energy simulations in the design process  of  a  building.  The  take-off  point  is  the  notion  of  energy  simulations  being needed early and throughout the building design process, and that the lack of energy simulations may be explained by the fact that they are time consuming and therefore often too expensive. A greater interoperability between software tools used by relevant disciplines,  such  as  the  architect  and  the  energy  specialist,  would  create  smoother workflows, which would reduce this cost and open up for more frequent and iterative energy  simulation  processes.  The  study  is  an  assessment  of  the  modeling  tool  Revit and  the  simulation  tool  Virtual  Environment  and  whether  they  can  create  smoother workflows, and make leeway for a more frequent use of energy simulations throughout the  design  process.  It  also  investigates  the  limitations  of  what  can  be  examined  by simulations in Virtual Environment. This will hopefully help clarify the future role of energy  simulations  in  design  processes.  The  method  is  a  trial  by  error  approach  of testing the two software tools by building and simulating a model. The results of these tests  show  that  the  workflow  is  not  optimal  (and  therefore  time  consuming)  for frequent  and  iterative simulations  throughout the  design  process,  but  it  also  reveals some  great  possibilities  of  what  can  be  performed  with  these  two  powerful  tools  at hand.  Further  development  with  regards  on  platform  independency  of  the  building information  model,  including  seamless  exporting  and  importing,  seems  necessary  to strengthen the future role of energy simulations..

Högtempererat borrhålslager för fjärrvärme

The district heating load is seasonally dependent, with a low load during periods of high ambient temperature. Thermal energy storage (TES) has the potential to shift heating loads from winter to summer, thus reducing cost and environmental impact of District Heat production. In this study, a concept of high temperature borehole thermal energy storage (HT-BTES) together with a pellet heating plant for temperature boost, is presented and evaluated by its technical limitations, its ability to supply heat, its function within the district heating system, as well as its environmental impact and economic viability in Gothenburg, Sweden, a city with access to high quantities of waste heat.The concept has proven potentially environmentally friendly and potentially profitable if its design is balanced to achieve a good enough supply temperature from the HT-BTES. The size of the heat storage, the distance between boreholes and low borehole thermal resistance are key parameters to achieve high temperature. Profitability increases if a location with lower temperature demand, as well as risk of future shortage of supply, can be met.

<- Föregående sida 22 Nästa sida ->