Sök:

Sökresultat:

110 Uppsatser om Anaerobic membrane bioreactor - Sida 1 av 8

Rening av avloppsvatten med anaerob membranbioreaktor och omvänd osmos

This master's theses was carried out on assignment from Stockholm Vatten AB as a part of a project developing new waste water treatment techniques. The goal of the theisis has been to evaluate an Anaerobic membrane bioreactor for treatment of waste water from Hammarby Sjöstad. The bioreactor has not been heated and the main interest has been to study the gas production, power consumption and the reduction of organic matter and nutrients.The system has been completed with a reverse osmosis unit and a total of four batch runs have been made with good results. The use of reverse osmosis allows nutrient in the waste water to be reintroduced into circulation as the reverse osmosis concentrate can be used as crop nutrient.The membrane unit is of VSEP ("Vibratory Shear Enhanced Processing") type and an extensive membrane test has been conducted. This so called L-test helped determine the most suitable type of membrane for the system to allow a higher ±ux and thus lower power consumption.

Uppgradering av biogas i systemperspektiv med avseende på miljöpåverkan och kostnader

Swedish biogas is currently produced mainly by anaerobic digestion of sewage sludgeat sewage treatment plants, landfills and anaerobic digestion of household or industrialwaste. Also cattle ma-nure from farms can be used to produce biogas. Upgradingbiogas represents an increase in methane concentration from about 65 % to about 97%. In addition, particles and contaminants must be sepa-rated from the upgradedbiogas. There are various methods for upgrading and this report compares sixdifferent methods with respect to environment and economy: water scrubber,Biosling, cryo technology, chemical absorption, Pressure Swing Adsorption (PSA) andmembrane separation.According to the used ORWARE model, chemical adsorption with amine has the leastenvironmen-tal impact (methane emissions) and the lowest costs.

Avloppsvattenbehandling med membranbioreaktor : En jämförande systemanalys avseende exergi, miljöpåverkan samt återföring av närsalter

In the pilot plant at Hammarby Sjöstad, Sjöstadsverket, several new methods are tested in order to achieve a good use of resources. When a new technique is considered it is often the performance of the technique itself, under given conditions, that is evaluated. However, in order to evaluate the overall function the whole picture is needed. With a system analysis it becomes possible to make a comparison where all the positive aspects are put up against the negative ones, for the technique itself as well as its requirements. In this way the influence that minor components have on an entire system can be considered.This report presents a system analysis of an anaerobic membrane reactor (MBR) with a VSEP-membrane (Vibratory Shear Enhanced Process).

Återvinning av näringsämnen från hushållsspillvatten med omvänd osmos

Hammarby Sjöstad is a new district in Stockholm with high environmental standard. Stockholm Water Company evaluates a local wastewater treatment plant with cutting edge technology. The first step is an experimental treatment plant (Sjöstadsverket) with four parallel lines of treatment, each with a capacity to treat wastewater from 150 persons. Within the membrane technology subproject the possibility of using reverse osmosis (usually called RO) to regain nutrients is examined.Reverse osmosis separates the incoming water in a clean permeate and a concentrate that, as the name indicates, is a more concentrated version of the incoming water. Using this method in wastewater treatment, a solution high in nutrients can be obtained without the use of chemical precipitation agent and with no production of sludge.

Anaerob rening vid StoraEnso Skoghalls Bruk

An analysis of a specific application of anaerobic wastewater treatment at a pulp and board mill, Stora Enso Skoghall, was carried out. A literature study was done and effluent wastewater from CTMP pulp production was analyzed. The analysis consisted of a broad constituent analysis and an anaerobic treatment trial. Results from these test where used to calculate the treatment effectiveness and resulting energy potential at the mill.The literature study and constituent analysis showed that toxicity of the water to be treated, due to wood extractives and sulphur content, was of concern. Detoxification chemicals targeting these constituents where used in the anaerobic treatment trial.

Vindpark Vänern : Fundamentteknik och Logistik

An analysis of a specific application of anaerobic wastewater treatment at a pulp and board mill, Stora Enso Skoghall, was carried out. A literature study was done and effluent wastewater from CTMP pulp production was analyzed. The analysis consisted of a broad constituent analysis and an anaerobic treatment trial. Results from these test where used to calculate the treatment effectiveness and resulting energy potential at the mill.The literature study and constituent analysis showed that toxicity of the water to be treated, due to wood extractives and sulphur content, was of concern. Detoxification chemicals targeting these constituents where used in the anaerobic treatment trial.

Analys av system för rening av avloppsvatten i en anaerob membranbioreaktor

The most common way to treat wastewater in Sweden today is by a combination of an activated sludge process and a chemical treatment. These processes are not very energy efficient and may not be the most environmentally friendly. That is why it is interesting to evaluate new alternative methods to see if they can be less harmful to the environment and help to a lower resource consumption. New techniques are tested in a pilot installation at Hammarby Sjöstad, Sjöstadsverket. To be able to evaluate these techniques in a wide perspective system analyses are conducted where different impacts can be considered, advantages and disadvantages in the systems.Five system structures for water treatment have been constructed in Matlab/Simulink in this study.

Klostridier och jästsvamp i ensilage ? orsak, verkan och samverkan

Yeast and Clostridia is a problem in silage for farmers as contaminated silage may result in poor animal health and milk quality. Clostridia can produce toxins that, when consumed, acts as neurotoxins, it may also cause blown cheeses if the Clostridia contaminates milk. The purpose of this study was to investigate the cause, effect and interaction of yeasts and Clostridia in silage. Clostridia are microorganisms which are strictly anaerobic and consume carbohydrates and protein in the silage. Yeast is a fungus that is facultative aerobic and feed on carbohydrates in the silage.

Utvärdering av en ny selektionsmetod för hingstsperma : med avseende på membranintegriteten och membranstabiliteten

Today, equine breeding is based on performance and conformation, resulting in a vast variation in fertility among different horses, with noticeable economic losses as a consequence. The horse breeding industry is therefore in need of methods that diagnose the spermatozoa concerning their quality and provide the best sperm for AI. The commonly used selection methods for sperm today are: centrifugation, where extender is added, the sample is centrifuged and then resuspended; swim-up self-migration; adherence separation; and density gradient centrifugation. However, none of these methods are in used routinely in practice before inseminating mares with fresh or cooled semen. The aim of this study was to evaluate a new selection method, Single Layer Centrifugation (SLC), and its effect on sperm viability. The viability was analyzed with regard to membrane integrity and membrane stability of ejaculated spermatozoa.

?-galaktosidas assay för studie av promotorregion i kloritdismutas från Ideonella dechloratans

Oxochlorates are anions with a partially naturally occurrence in nature but are also spread by human activities, including the paper industry. These compounds are harmful to both nature and humans, which makes it necessary to find a good way for their degradation. There are two different kinds of bacteria that can use oxochlorates as electron acceptors in their metabolism, bacteria that break down perchlorate and bacteria that break down both perchlorate and chlorate. A bacterium that can break down chlorate under anaerobic conditions is Ideonella dechloratans which holds the genes for chlorite dismutase and chlorate reductase which are enzymes for the degradation of chlorate. Gene expression and enzyme activity of chlorite dismutase are induced under anaerobic conditions, which makes it interesting to find out how this regulation functions in order to better exploit these bacteria in biological wastewater treatment.

Utvärdering och jämförelse av olika fälttester för fotbollsspelare

Different field tests are currently used in a wide extent in different levels of soccer teams. To be able to assess the players? physiological status the tests must have high validity, reliability and external validity. Many different tests have been developt, but currently only five of these tests are most commonly used: Yo-Yo intermittent recovery test (YIRT), Yo-Yo intermittent endurance test (YIET), Multi-sprint-test, Beep-test and Cooper-test. Presently there is no definitive conclusion regarding which of these tests is most suitable for soccer players.

Detektion av mRNA från en cytokrom c gen belägen i genklustret för kloratmetabolism i Ideonella dechloratans

Abstract:In previous experiments with the bacterium Ideonella dechloratans a probable sequencecoding for a cytochrome c protein (cyt c) was observed, the sequence is assumed to have afunction in the bacterial respiratory chain. Detection attempts have been made to try to findthis protein, but have not succeeded. The purpose of this project is to detect the expressionof mRNA associated with the cytochrome c. And if it is detected, it will also be investigated ifthere is any difference in expression of the mRNA due to aerobic or anaerobic environment.Total RNA was purified from cultures grown under aerobic and anaerobic conditions. cDNAwas then synthesized using reverse transcriptase and subsequently amplified with thespecific primers in a qRT-PCR.qRT-PCR testing showed a distinct amplification of primer product, confirming that I.dechloratans expresses mRNA coding for the cyt c protein.

Faktorer som påverkar magnesiumabsorptionen i våmmen hos kor

In metabolism Mg plays an important role because it affects many cellular enzymes in the body. The energy metabolism and protein synthesis are dependent on Mg as an enzyme activator, Mg is also involved in the synthesis of RNA and DNA. Absorption of Mg primarily takes place over the ruminal epithelium in ruminants. The main storage of Mg is in the bones but that can only be reached if the cow is in great need of calcium or phosphorus, it's a hormonal regulated process that induces catabolism of bones. Free and available sources of Mg are found in soft tissues and in the extra cellular fluids that includes cerebrospinal fluids and blood.

Anaerob psykrofil behandling av hushållsavloppsvatten i UASB : Utvärdering av kapaciteten hos en två-stegs UASB-reaktor för behandling av hushållsavloppsvatten

Hammarby Sjöstad is a new district in southern Stockholm. A main objective with the Sjöstad project was to halve the environmental impact compared to other construction work. The environmental goals involve a halved water consumption rate, a local treatment of storm water and trials aiming to extract nutrients from the waste water. Sjöstadsverket is an experimental treatment plant used for testing new treatment processes for domestic waste water from Hammarby Sjöstad. The results are to be compared with the conventional process used at Henrikdals treatment plant today.

Effekterna av praktisk ocklusionsträning periodiserat med ett traditionellt styrketräningsprogram på anaerob prestation

Background: Practical blood flow restriction (pBFR) combined with resistance training has been proven to facilitate muscle strength despite training at low intensity. However, research investigating the effects of long-term pBFR-training and its periodization with strength training (ST) at a higher intensity is lacking, as well as the effects of occlusion training on blood lactate levels (BLL) over time.Purpose: To compare the effects of 2 weeks of pBFR training followed by 2 weeks of ST (BFR-ST) with 2 weeks of ST followed by 2 weeks of pBFR training (ST-BFR) on anaerobic performace and BLL.Method: 5 adults (age 23 ± 2 years) with a minimum of 1 year of ST experience were recruited and randomized into BFR-ST (n=2) or ST-BFR (n=3). Anaerobic performance was measured using a 30-s Wingate-test and BLL samples were collected <1 and 5 minutes post-Wingate. Data and samples were collected before the intervention and after the 2 protocols.Results: No differences were seen between groups in anaerobic output or BLL after 4 weeks of training (p>0,1 for all values). A decrease in time to peak power (tPP) were seen in both groups with an advantage for BFR-ST (-37 ± 8 %) over ST-BFR (-27 ± 22 %).

1 Nästa sida ->