Examensarbete, avancerad nivå
Validering av vattenkraftmodeller i ARISTO
Sammanfattning
This master thesis was made to validate hydropower models of a turbine governor,
Kaplan turbine and a Francis turbine in the power system simulator ARISTO at
Svenska Kraftnät. The validation was made in three steps. The first step was to make
sure the models was implement correctly in the simulator. The second was to
compare the simulation results from the Kaplan turbine model to data from a real
hydropower plant. The comparison was made to see how the models could generate
simulation result that was similar to the reference power station. The third was to
validate in which way the Francis turbine model influenced the simulation result from
a small power system. Data from the Swedish black start test system was available
and used as reference data. The main question for step three was if the simulation
result got better and more like reference data if the Francis turbine model was used.
The result showed that the models was correct implemented in ARISTO and that the
models can generate simulation result that was similar to reference data if the correct
parameters was collected from individual power plants. The torque tables for the
turbines models and the parameters for the PID-controller in the turbine governor
had greater impact on the simulation results then other parameter in the models.
Key word: turbine, hydropower models, power system simulation