Uppsatser om reference sample
63 uppsatser · sida 1 av 5
en utvärdering av QBC-V och Scil Vet abc för analys av prover från hund och katt
Examensarbete · SLU
… Sciences (SLU), Uppsala, Sweden. The QBC-V and Vet abc were compared to a reference instrument, the Cell-Dyn 3500. Fresh blood samples were obtained from canine and feline patients from the University Veterinary Hospital, SLU. The QBC-V was used for 111 canine samples and 78 …
Kandidatuppsats · Linnéuniversitetet
… marrow. The purpose of this project was that by approved methods to establish reference ranges for the parameters, RDW and reticulocyte counts. The individuals who participated in the study, n=124, were considered healthy and had varying ethnicity. Reference subjects had not …
Hur förändras ackumulationen i sjöar påverkade av avverkning jämfört med referenssjöar?
Kandidatuppsats · Umeå universitet
… differs between years and between lakes affected by clearcutting and untreated reference lakes. Water- and gas samples were collected from four boreal lakes (two affected by clearcutting and two untreated reference lakes) located in Västerbottens inland in spring. The lakes were …
Examensarbete · SLU
Establishing a reference interval for plasma fibrinogen in foals Fibrinogen concentrations were analysed in EDTA preserved blood plasma samples from 34 thoroughbred foals born in 2001 and 2002 at one stud farm. The foals were between 0 and 240 days old at the time of the …
Kandidatuppsats · Uppsala universitet
… that almost all normetanephrine results for women were higher than the upper reference limit and therefore pathological, the accuracy of the present reference intervals was questioned. Therefore new reference intervals for both urinary catecholamines and methylated …
Magisteruppsats · Lunds universitet
… limestone from the Sinemurian stage in the lower Jurassic was sampled. As a reference, a sample comprising 14,0 kilogram from the chromite- enriched part of the middle Ordovician Orthoceratite Limestone was examined. In this study, a total of 3 extraterrestrial chromite grains …
Examensarbete, grundnivå · Linköpings universitet
The interest in tiny wireless applications raises the demand for an integrated reference oscillator with the same performance as the macroscopic quartz crystal reference oscillators. The main challenge of the thesis is to prove that it is possible to build a MEMS based …
Examensarbete · SLU
… group. To be able to compare these results 20 other farms were picked out as a reference group. This group also had to answer the inquiry. A sample from the manure storage was taken at each farm in the compared groups. This sample was used in the study and would represent the …
Övrigt arbete · SLU
… is unique for each species, is used. For identification of fungal species a reference library was prepared from the ITS sequences of pure isolations of fungi on the beans and the inserted fungal ITS sequences in cloned Escherichia coli bacteria. The ITS regions were sequenced …
Kandidatuppsats · Malmö högskola
… analyzed with glass- and plastic hemocytometers with Sysmex XN-2000 as the reference method. The study results showed high correlation between the reference method and plastic hemocytometer at low PLT but were not suitable for WBC-determination. The capillary whole blood showed …
ett odlingsförsök vid tre rödfyrshögar i Västra Götalands län
Examensarbete · SLU
… alun shale and lime mixed with peat, only burnt alun shale and lime, and a reference soil. The reference plots were natural soil mixed with peat adjacent to the mounds. After harvest the vegetables were dried and weighed in order to determine the growth. Growth medium samples …
evaluation of kit for low-cost and fast preparing of DNA-samples before genotype analysis
Kandidatuppsats · Uppsala universitet
… was evaluated. QIAamp® DNA Blood Biorobot® MDx Kit was used as the reference method. The purpose of the comparison was to find a method that makes DNA extraction from blood samples cheaper and faster, but with the same reliability as the reference procedure. The results of the …
Magisteruppsats · Högskolan i Kalmar
… have been measured on all samples. The chemical values were then compared to reference values in order to establish the level of contamination. Within the risk assessment framework where then also a exposure modelling conducted. This was made both for an average exposure …
Examensarbete, avancerad nivå · SLU
… study, laser data was used to classify the forest in the Abisko area, using reference data from sample plots. From the point cloud obtained from the laser scanning, different types of metrics were calculated and used to classify the forest. Classification results were evaluated …
effect of pH, carrageenan and storage time
Masteruppsats · SLU
… T3 (low pH; high carrageenan), T4 (high pH; high carrageenan) and a reference (center point). The products consequently had two factors varied at three levels; high and low pH and high and low concentration of carrageenan; and a center point with values between high and low. The …