Uppsatser om passive-house
68 uppsatser · sida 3 av 5
Kvarter Trettondagen
Högskoleuppsats · KTH
… a requirement that ”Kv. Trettondagen” should reach the technical standard of a passive house. Calculations by hand does not give a result that matches those requirements but calculations using data-driven energy calculation programs shows a result that meets the requirements of …
Kandidatuppsats · Högskolan i Halmstad
This thesis tries to clarify why more houses such as passive houses is not built and at the same time the differences is described with the conventional construction as a starting point. Sweden has set environmental objectives to reduce energy consumption in buildings by 50 …
Kandidatuppsats · Karlstads universitet
… energy-efficient multi-dwelling buildings. The report is based on Älvstrandens passive house, Hamnhuset, a house whose energy consumption is far below the BBR's requirements. The report looks at the opportunities for improvement within windows, insulation, solar energy …
Kandidatuppsats · Växjö universitet
… U-values the building is given is matched to the values of recommendation for passive houses. Our reference house is a two story apartment building, located in the village of Lammhult, with brick facades at the ends and plaster at the long sides. One of the long sides contains …
En fallstudie av ett flerbostadshus, Kv. Fyrtornet
Masteruppsats · Mälardalens högskola
… performed, by using a package of measures, the building has been upgraded to a passive house level and the energy demand has become 21, 5 kWh/m2 annually. A reasonably large amount of energy has been reduced in connection with the improvement package as well as the whole …
Högskoleuppsats · Linköpings universitet
… for a dwelling in Boverkets Building Regulations. The difference between a passive and a typical air tight construction is that the passive house have a maximum requirement of 0.3 l /s m2 of air leakage through the building climate screen. The requirement imposed on passive …
En jämförelse mellan en platstillverkad konstruktion och prefabelement från Masonite Lättelement AB
Examensarbete, grundnivå · Uppsala universitet
… incorporated into ahouse projected to accomplish the demanding criteria of a passivehouse. The thesis is organized as a comparison betweenthe prefabricated elements and an on-site built component fromthe passive house area of Oxtorget in Värnamo, Sweden. Theaspects investigated …
En studie av två verkliga byggnader
Examensarbete, avancerad nivå · Uppsala universitet
The aim of this report was to investigate the economy of passive houses. The work was focused on economy in total and on the economy of different components such as windows, insulation, heat exchanger and the air tightness of the climate shell. No attention was paid on the …
Examensarbete, avancerad nivå · Uppsala universitet
… flow proportional measurements which were more expensive and complicated, and passive measurement, which were simpler and cheaper. A comparison between the measurement methods was done in order to be able to use only the passive measurement method at the next sampling session …
Examensarbete, grundnivå · KTH
A passive house in Norra Djurgårdsstaden drawn by Tengbom Arkitekter is going to be built. A shaft for airing is needed for a few apartments in the house. The airing shaft is designed for a few two room apartments in the house, which are not able to achieve satisfactory airing …
Examensarbete, avancerad nivå · Uppsala universitet
This master’s degree project concerns the combination of a multi dwelling passive house with solar energy for the generation of electricity and domestic hot water (DHW). Different alternatives with either solar thermal systems or photovoltaic (PV) systems are compared with two …
Brand- och fuktegenskaper i passivhuskonstruktion
Examensarbete, grundnivå · Uppsala universitet
… the company currently uses in the establishment of Sweden's first certified passive house for international standards. Their current material, Rockwool, is compared to a relatively new material on the Swedish market called SEALECTION Agribalance sold by the company ISO Green AB …
En jämförelse mellan Miljöbyggnad, Svanen, FEBY12 och PHI
Examensarbete, grundnivå · Högskolan i Gävle
… should be calculated currently. Key words: environmental assessment tools, Passive house standards, Miljöbyggnad, Svanen, FEBY12, PHI, energy, environmental impact
Förstudie Till Aktivhusområde i Halmstad
Kandidatuppsats · Högskolan i Halmstad
… aboutongoing work in the field of energy efficient buildings and active house which we have usedto develop a model. The feasibility study for Ranagård we have e.g been forced tofollow laws on groundwater covered, resulting in the construction of basements for singlefamilyhome is …
Högskoleuppsats · Umeå universitet
… buildings energy performance have been sharpened through the years. Today, ”passive house” and ”low energy house” are commonly used phrases in the construction industry and is expected to become increasingly common in the future. For houses with well-insulated building envelope …