Uppsatser om insulation
113 uppsatser · sida 2 av 8
Kandidatuppsats · Högskolan i Jönköping
… chosen U-value of 0,1 W/m2 ° C, without getting to thick. Therefore additional insulation is needed. There are few relevant reference objects built with only light weight concrete. A villa in Lomma, Sweden, has been designed but is not yet built. The house has no additional …
Examensarbete, grundnivå · Uppsala universitet
… to use less energy. Replacement of old windows and doors, using more insulation, replacement of old less efficient insulation with new improved materials, using a different heating system, and more. One factor, which is more important than all the others, is to insulate between …
Kandidatuppsats · KTH
… consumption. The second part of the work is a deeper study dealing with window insulation. With window insulation is meant removable and insulating constructions that are in use for instance on nights, but can be removed when the windows are needed for daylight and view. The …
Kandidatuppsats · SLU
… season is important. Acclimatisation is to provide means for a good thermal insulation consisting of skin, hair, and an outer air layer. The skin covers the horses body and it is composed of three main layers where the top layer of the epidermis consists of dead keratinized …
Högskoleuppsats · Högskolan i Halmstad
… Sa?tra. This study aims to investigate and evaluate proven methods for adding insulation in the four floor types. Also to look for solutions by designing additional insulation to treat damp problems and improve energy efficiency in an economical way. Existing flooring types are …
Chefsbostaden i Strömsholm, ett timmerhus från 1900-talets början
Examensarbete, avancerad nivå · Mälardalens högskola
… studies, interviews and inspections. Based on these findings, supplementary insulation on the inner side of the climate screen was decided on. The program IDA Indoor Climate and Energy was used to make computer simulations of the energy consumption of the building for five …
Kandidatuppsats · KTH
… valve on at the top of the vent stack, on the roof, varies from 3 to 13 W. If insulation is used around the vent stack, one is able to save around 4 to 15 W and between 2 and 6 W for the valve. In addition to this, there are losses due to heated air flowing out from the vent …
Examensarbete · SLU
… pigs. Different heights of the roof (opening area), and different amounts of insulation have been studied for the effect of differences in air temperature, outside the cottage compared to the inside of the hut, ?T. Roof heights between 400 mm and 700 mm have been studied. Roof …
Med inriktning mot hållfasthet och dämpning av ljud
Masteruppsats · KTH
… for the compressor space gives a reduction with three dB. By using the insulation for the heat water tank as absorbent we can see a sound reduction on the lover octave bands. A reduction like this is elsewhere hard to achieve as at it requires thick absorbents. By changing the …
Kandidatuppsats · Högskolan i Halmstad
… describes the amount of heat transfered through a building element, the more insulation, the smaller U-value. A typical passive house wall have a U-value of 0.10 W/m2,°C. The passive houses are primarily made as small family houses and not as a block of apartments. This is …
Kandidatuppsats · Högskolan i Jönköping
… polystyrene beads (EPS). This substitution gives a product with higher insulation values but lower weight than ordinary concrete. The work was carried out by designing a survey which was sent to two hundred randomly chosen companies across Sweden, to see the building industry’s …
Examensarbete, grundnivå · Chalmers tekniska högskola
… action packages that should be implemented. In the report the actions addinginsulation and window relacement have been deeply studied and a compilation havebeen done where the energy savings are set against the cost for each action. Thepurpose of the report is to invesigate …
Kandidatuppsats · KTH
… carbon dioxide emissions. A change of, for example the ventilation system, the insulation or windows might lead to energy savings and reduced carbon dioxide emissions. This report has examined a specific million program house and a specific house recently built to perform a life …
Högskoleuppsats · Högskolan i Gävle
… U-value of an exterior wall construction when airflow occurs in the thermal insulation layer. The concept of windproofness is in the current situation a word in the building sector which is rarely used. Instead, the word airproofness with the assumption that it is the same but …
Rekommenderade avsteg från IEC 60076 för att vid upphandling beskriva en robust enhet
Examensarbete, avancerad nivå · Uppsala universitet
… regarding mainly hot spot temperature rises; Type and properties of the insulation; Quality and performance of the manufacturing facility; Ability to withstand external short circuit; Loss evaluation, since the magnitude of the losses dictates the forces developed during …