Sök:

Mekanisk integration av en IR-detektor i en Stirlingkylare

The master thesis ?Mechanical Integration of an IR-detector in a Micro Cooler? has beenperformed at FLIR Systems AB in Danderyd. FLIR Systems is a world leader in the design,manufacture and marketing of thermal imaging camera systems.The thesis project is divided into to two areas, Production Method and Noise.The Production Method concerns the positioning of a detector on the cold finger within the IRcamera.The detector has to be positiond with very high accuracy at the center of the cold finger,so it can be placed in line with the optical axis to avoid movement of the picture during zooming.The positioning of the detector is at present done with the help of specially designed guides on aplate on top of the cold finger. The design workes well but the special machining needed for thisplate is very expensive.The goal concerning the production method was to derive a new more cost effective method forthe assembling and positioning of the detector on the cold finger by replacing the guides on theplate with a reusable equipment or some other alignement operation.Several concept ideas have been generated with the help of concept generation methods in theform of concept classification trees and concept combinational tables. Two of these conceptswere selected to be further refined. The selection was done with the help of a concept scoringmethod and a concept evaluation meeting. In the first concept the detector is positioned with thehelp of a microscope and in the second with the help of an external fixture. A prototype of thefixture has been manufactured and an evaluation was done concerning function and priceaspects. This showed that the positioning of the detector will be good and the assemblers werepositive towards the fixture and the handling of it. The investment of the fixture will be returnedcompared to the plate with the guides after only four assembled detectors.The Noise part of the thesis concerns a disturbance that sometimes can be seen in the picture.This disturbance, here called flicker, seem to be generated by the Stirling micro cooler since thefrequency of the flicker follows the frequency of the cooler. The cause of this flicker is unknowndespite numerous of studies. The goal concerning the noise was to do studies in order to confirmor refute some hypothesis. Experiments, simulations and calculations have been done to analysethe deformations in the detector caused by pressure pulsations and the effects on the detector byvibrations of the cold finger caused by the Stirling micro cooler. However these studies did notgive a clear conclution to the cause of the flicker and therefore further studies have to be done.

Författare

Camilla Gibson

Lärosäte och institution

KTH/Maskinkonstruktion (Inst.)

Nivå:

"Masteruppsats". Självständigt arbete (examensarbete) om 30 högskolepoäng (med vissa undantag) utfört för att erhålla masterexamen.

Läs mer..