Sök:

Hur påverkar byggnadsmaterial av stål en induktiv hörslingas fältstyrka samt frekvensgång?


This research analyzed differences in measurements of magnetic field strength and frequency response in five audio induction loops installed in rooms of wooden construction materials and five audio inductive loops installed in rooms of steel reinforced concrete constructions. The inductive loops were installed at floor level and the measurements were made at the listening height of 1.2m. Measurements of background noise, field strength and frequency response were made at fifteen different measurement points across the room. The research measurements showed that there are differences in field strength and frequency response between these two conditions, whether the audio induction loop is installed in a wooden construction or the audio induction loop is installed in a reinforced concrete construction. The results had a significance level of p=0,05.

Författare

Fredrik Olofsson

Lärosäte och institution

Luleå/Institutionen för konst, kommunikation och lärande

Nivå:

"Kandidatuppsats". Självständigt arbete (examensarbete ) om minst 15 högskolepoäng utfört för att erhålla kandidatexamen.

Läs mer..