Sökresultat:
9 Uppsatser om Intraoral - Sida 1 av 1
Normering av test av intraoral stereognosi och tvåpunktsdiskrimination : Hos barn i åldrarna 5;6 - 7;0 år
The oral sensory ability in children can be assessed through test of Intraoral stereognosis and two-point discrimination. Currently, these two tests are not frequently used in clinical settings, and normative data are not always available. The aim of this study was to establish normative data for these two tests in children aged 5;6 to 7;0 years. Further, intention was to compare the results with respect to age and gender. In total 103 children participated, 49 boys and 54 girls.
En ny metod för intraoral röntgenundersökning på häst :
A method for equine intra oral radiology has been tested. In the study, both a digital system with an Intraoral sensor connected to a laptop and a system utilizing image plates and digital developing was tested, initially on cadaver sculls and finally on sedated horses.
The digital sensor was not considered viable for this purpose, while the system with image plates and digital developing worked very well. Two different techniques, i.e. parallel and bisectris, are suggested for the best visualization of different parts of the teeth. Intra carious injections of Mixobar oesophaghus contrast fluid was found useful when evaluating the extent of carious lesions.
Compared to extra oral radiology, the new method had several advantages and can be used both in clinic and field practices..
Orthodontic diagnostics and measurements on digital study models made with an intraoral scanner
Introduktion:
Modellanalys har traditionellt gjorts på fysiska gipsmodeller. Idag finns ny teknik som möjliggör framställning av digitala modeller utan behov av konventionella avtryck. Syftet med den här studien är att undersöka tillförlitligheten hos digitala modeller framställda med en Intraoral scanner, patientupplevelsen och olika tidsaspekter förenade med tekniken.
Metod:
På ett urval av 20 vuxna personer gjordes både konventionell avtryckstagning och en Intraoral scanning (TRIOS, 3Shape) av bettet för framställning av gipsmodeller och digitala modeller. Den kliniska tidsåtgången mättes och personerna besvarade ett frågeformulär gällande sin upplevelse av metoderna. Fyra observatörer diagnostiserade bettrelationer och utförde ortodontiska mätningar på gipsmodeller med ett skjutmått och digitala modeller med OrthoAnalyzer Orthodontics (3Shape, Danmark).
A standardized method for evaluating trueness and precision of intraoral scanners ? in vitro accuracy
Bakgrund. En gyllene standard för att bestämma noggrannheten för Intraorala scannrar
existerar inte. Intraorala scannrars prestanda som ges av olika leverantörer är inte fullt
jämförbara. Det finns ett behov att standardisera och ta fram oberoende försöksupplägg för att kunna jämföra Intraorala scannrar.
Mål. Målet med studien var att beskriva och utvärdera en ny metod för att bestämma
noggrannheten av Intraorala scannrar genom ett standardiserat in vitro testförsök och att
använda metoden för att beräkna noggrannheten på en kommersiell Intraoral scanner.
Material och metod.
Fotografisk diagnostik av Molar Incisor Hypomineralization: Test av validitet och reliabilitet
Molar Incisor Hypomineralization definieras som ett specifikt tillstånd orsakat av störningar i den tidiga fasen av emaljbildning av en eller flera permanenta första molarer med eller utan involvering av permanenta incisiver. Tidigare studier har visat att standardiserad Intraoral fotograferingsteknik kan vara användbar för epidemiologiska studier av emaljdefekter. Denna studies syfte var att utveckla och utvärdera en fotografisk klassificering av allvarlighetsgraden av Molar Incisor Hypomineralization genom att studera metodens validitet och reliabilitet. 164, 10-12 åriga svenska barn granskades fotografiskt avseende prevalensen av Molar Incisor Hypomineralization. Först granskades endast första molarens ocklusalyta, därefter ocklusal- och buckalyta.
FORL : Feline Odontoclastic Resorptive Lesions
This report was written in an attempt to summarize old and new theories and scientific
results regarding FORL (Feline Odontoclastic Resorptive Lesions). Several different kinds
of treatment are presented in this study. Among them teeth extraction and crown
amputation seems to give the best long-term results. It seems clear that the domestic cat of today have no trouble digesting dry foods without their teeth. The most accurate way to diagnose FORL is by using Intraoral dental radiology technique.
Patientens upplevelse före och under behandling av obstruktiv sömnapné med intraoral apparatur
Syftet med studien var att undersöka patientupplevelsen vid behandling med sömnapnéskena hos patienter med diagnosen obstruktiv sömnapné utförda i allmän tandvårdspraxis. Studien genomfördes som en tvärsnittsundersökning i en av de större regionerna i Sverige, region Skåne. Undersökningen var retrospektiv i sin design och bestod av en enkät sänd till de patienter med en verifierad obstruktiv sömnapné som fått sin odontologiska behandling som ett led i sjukdomsbehandling. Behandlingen skulle ha pågått minst 6 månader. Enkäten skickades ut till 1148 patienter, varav 738 svarade (64 %).
Hur väl överensstämmer tandslitage på intra-orala foton med klinisk registrering?
Syftet: Målet med studien var att utvädera kliniska Intraorala foton som diagnostisk metod för att bedöma tandslitage (attrition, erosion och abrasion) och jämföra dessa bedömningar med kliniska registreringar.
Material och metod: Studien genomfördes på Tandvårdskolan i Malmö, där man slumpmässigt valde ut 30 vuxna patienter. Dessa patienter undersöktes med avseende på tandslitage (attrition, erosion och abrasion) och kliniska foton togs. En månad efter kliniska registreringen gjordes en bedömning av de kliniska fotona, utan att ha kännedom om resultatet av de kliniska registreringarna. Båda undersökarna har på samtliga patienter utfört klinisk registrering och fotobedömning oberoende av varandra. Intra- och interobservatör överensstämmelse uppskattades genom Cohen?s Kappa- koefficient.
Resultatet: Intraobservatör överensstämmelsen mellan bedömningar av foton och kliniska registreringar var måttligt-till-god med ett P-värde på 0,039-0,046.
Normativa data för samband mellan subglottalt tryck och ljudtrycksnivå
Syftet med föreliggande studie var att undersöka sambandet mellan subglottalt tryck och ljudtrycksnivå, och undersöka inverkan av kön och tonhöjd. Röststyrkan är starkt beroende av subglottalt tryck och sambandet har analyserats i ett flertal studier, som alla visar på ett linjärt förhållande mellan logaritmen av subglottala trycket och ljudtrycksnivån (SPL). Schutte (1980) analyserade sambandet för 21 kvinnor och 24 män som producerade ett stort antal mätdata med olika SPL och tonhöjd. Tryck mättes med ballong i esofagus. Tanaka & Gould (1982) analyserade 4 kvinnor och 6 män på tre ljudnivåer på bekväm tonhöjd; svag, normal och stark ljudstyrka.