Sök:

Sökresultat:

17 Uppsatser om Compressor - Sida 1 av 2

Provmetod för olje- och partikelöverdrag från kompressor till tryckluftssystem

Compressed air is an energy source that is widely used in today's trucks and buses.Compressor located next to the engine supplies the pneumatic system with the compressed air and is lubricated with the engine oil. Some of the oil follows the air flow in both liquid and solid phase. The solid phase, namely the carbon particles are created due to the high temperature in the compression chamber.Oil- and particles carryover softens and destroys the rubber material in the air valves and disturbs the mechanical function of various components in the pneumatic system. In order to reduce oil- and particles carryover is an Air Processing System (APS) set downstream the Compressor.No method for establishment of oil- and particles carryover from the Compressor exists at the moment. Therefore the filtration efficiency of APS is currently unknown.

Vibrationsdämpning av värmepump

Thermia Värme AB is one of the market leading manufactures of heat pumps. In order tomaintain this position, the company wants to improve the vibration characteristics of theirproducts. The aim of this thesis is to develop product design changes that lead to a reductionof vibrations in the heat pump Thermia Diplomat 8.The main cause for vibrations in the system is flow pulsation and mechanical forces inducedby the scroll Compressor. Vibration is transmitted through the Compressor piping and receivedby the heat exchangers, from where it is further transmitted to the connection points for theradiator and heat source circuits.A number of design changes in order to improve the vibration characteristics have beenevaluated through calculations and practical experiments. The changes have included theCompressor and heat exchanger mountings, the Compressor suction and discharge line pipingand also pulsation dampening.The results of the experiments show that the vibration levels in the connections for the heatingand brine circuits can be decreased strikingly through changes in suction and discharge linepiping.

Ljudreducering av värmepump

This degree project handles acoustic measurements of the heat pump EcoAir 107, made by Enertech CTC AB. The sound from the three sound sources of the heat pump, fan, Compressor and four way valve, have been measured to find out how they affect the total sound level of the product.Measures to attenuate the sound level have been developed and tested. By comparing these with the sound of the heat pump, in its original state, we have found out the measures which have best effects.The best attenuating measures came to be: taped openings and holes around the Compressor space, isolating the top and the bottom of the whole construction, support of the fan bottom part and shielding of the sound source with a screen at a distance of 110 mmThese measures have been tested together and an average attenuation of the total sound level with 3,9 dB have been accomplished. In the front of the fan where the continuous sound is the strongest, the attenuation was 4,7 dB.This project is meant to be used as a guide by Enertech CTC AB:s during their future developing process..

Skalkonstruktion : Med inriktning mot hållfasthet och dämpning av ljud

The sound part is mainly practical and is dependent on concepts that have been tested through measuring with a sound level meter. The design part is more theoretical and has been verified with CAD models and finite element analysis.With a sound damping hood on the Compressor the sound level is reduced with up to four dB. An optimized absorbent for the Compressor space gives a reduction with three dB. By using the insulation for the heat water tank as absorbent we can see a sound reduction on the lover octave bands. A reduction like this is elsewhere hard to achieve as at it requires thick absorbents.By changing the today?s insulation to the heat water tank to a form of polystyrene polymer insulation the weight from the heat pump above can be transferred to the stable heat water tank.

Utökning av mätområdet för turbinverkningsgraden på avgasturbo

The Goal with this Master of Science thesis is to expand the possible turbine efficiencymeasurements on an exhaust turbocharger. It was done as a part of the CICERO competencecentre. To feed the turbine with air a special flow rig has been used. Instead of loading theturbine by just restricting the Compressor flow a docking system for an electrical dynamometer isdesigned to use the dynamometer as an additional loading source. By using an electricaldynamometer as loading device for the turbine, measurements are not depending on Compressorperformance.A large part of the work consists in designing accessories for the dynamometer.

Effektivare energianvändning på Totebo AB

The main goal with this thesis report was to come up with ideas of how to make the use of energy more effective and thus save money for the company.First a survey was made to find out where and how the energy consumers were divided within the company. The results were then used in calculations to find out how much money that could be saved and how long it would take to get back the investments.There is a big potential in saving money by recovering heat from the UV-lamps with a heat exchanger. It would also even out the pressure in the factory which is a source to heat loss and a cause for discomfort amongst the employees. It?s possible to save 105 000 kr in a year and the money needed for the investments is 600 000 kr.By using the recovery air more effectively the company could save up to 250 000 kr a year in lowered heat purchases, but this would require the use of automatic dampers.If you reschedule the running times for the wood chipper and invest in some kind of load management, for example Sydkraft?s ?Energidirigent? you can save at least 42 000 kr.

Beredning av köldbärare för komfortändamål i kontorsverksamhet : En studie i produktionsslag

The real estate company Ihus is facing an expansion of its comfort cooling in Noatun,Uppsala, to provide the buildings in the block with cooling. The buildings in Noatunare mainly used for office premises, where the requirements for an accepted indoorclimate is great. However, it?s uncertain whether Ihus should continue, as currently,producing comfort cooling by themselves using a Compressor chiller, or if they shouldconnect themselves to Vattenfall?s district cooling net.The purpose of this report is to examine which technique of cooling is best suited forIhus and their buildings in Noatun. It should also work as a guideline for othercompanies facing the same problem as Ihus.

Energieffektivisering i ett verkstadsföretag : En analys av energibesparande åtgärder samt uppvärmnings- och kylsystems driftkostnader och koldioxidutsläpp

The energy use in a workshop company has been examined in this work in order to find areas for energy efficiency improvement. The combined oil and electricity heating in the company were compared with other alternative heating systems including cooling of the premises in following combinations:Ground source heat pump for heating and coolingDistrict heating and absorption coolingDistrict heating and low temperate surface water coolingEnergy use, operation costs and carbon dioxide emissions were calculated for the current heating systems and the three alternatives including cooling. The ground source heat pump for heating and cooling decreases bought energy with 34 MWh annually compared to current heating only. The district heating and low temperate surface water cooling has the largest reduction of operation cost and carbon dioxide. The operation cost decreases with 42 kSEK and the carbon dioxide with 43 metric ton CO2 annually.

Effektivisering av kylsystem på Utö värdshus

Energy consumption is at present a major political issue, and numerous projects that comprise many nations are currently in process to increase energy efficiency and bring down energy dependency. As a member state of the EU, Sweden now faces the challenge of implementing substantial energy-saving measures until the year 2016. One of these measures is the project ?Green Islands? financed by the EU that intend on creating sustainable islands in areas around the Baltic Sea. The Archipelago Foundation leads the project that concerns the Stockholm archipelago, where focus has been placed upon decreasing energy usage in businesses and services on Utö among other islands.

Kyla i Nyköping och Motala : Kartläggning av kylapotential för Vattenfall Värm

The Swedish energy company Vattenfall is currently the owner of the district heatingsystems in Nyköping and Motala. To be able to also offer cooling solutions tocustomers are becoming more and more important. This report describes the resultsof an investigation of the cooling market in the two cities and the potential needs forcooling today and in the coming 20 years. The total potential for the coming 20 yearsis estimated to be roughly 17 MW for Nyköping and 9 MW for Motala.Two possible district cooling systems for each of the two city centers was modeledand a comparison was made between different cooling techniques namely absorptionand Compressor chillers.Absorption chillers driven with district heating during the summer is one way ofincreasing the load in a combined heat and power plant and thereby the possibleelectricity generation. The cost of heat production must be low for absorption chillerto be able to compete as an alternative.

Potential för värmeåtervinning från mjölkkylanläggningar

The present climate discussion has made energy efficiency an interesting topic. Saving energy does not only help the climate but also saves money for the energy consumer. The purpose of this thesis was to examine the potential of heat recovering from milk cooling. Two milk farms, one with voluntary milking system, VMS, and the other with conventional milking system was used to measure interesting temperatures and electricity consumptions. The numbers were used both to do theoretical calculations and to construct a SIMULINK model. To calculate the potential for heat at milk farms theoretical calculations were made in MATLAB using a reference farm with different combinations of heat recovery and pre cooling. The farm was assumed to keep a dwelling house with the annual heat consumption 18165 kWh.

Energieffektivisering av färskvattensystemet på Skärblacka pappersbruk

The purpose of this master thesis was to study the water system for mechanically cleaned water at Skärblacka mill, in order to find and evaluate possibilities of using energy more efficiently. The thesis also includes an evaluation of the software tool ?Pumpanalys?Skärblacka mill produces pulp and paper. The large amount of water required is cleaned mechanically through filters and called mechanically cleaned water (MR0). The MR0 water is pumped out to the factory by four crude water pumps.

Att klona en klassiker: En undersökning av klonens kvalitet

I studien ja?mfo?rs de subjektivt upplevda ljudegenskaperna mellan Solid State Logics Console Mixbuss Compressor och en hemmabyggd klon av samma kompressor. Klonen a?r framtagen av Gyraf Audio och ga?r under namnet GSSL. Ja?mfo?relsen gjordes med data fra?n ett lyssningstest da?r syftet var att ta reda pa? om testdeltagarna upplevde na?gon skillnad mellan kompressorerna och i sa? fall vad som skiljer dem a?t.

Mätningar och analys av elnätet hos FHP, Basproduktion

This report is a degree project performed at Freudenberg Household Products AB, (FHP). The degree project comprises measurement and analysis of the power net at FHP Basproduction. The content is divided between one theory-part, one document- part with measurements and also conclusions and a list of measures to be taken. During the project the purpose and restriction change from a quality investigation to only concentrate on harmonics and finding the reason why they exist, and also to find a solution to the problem with harmonics. The measurements shows that the power net contains harmonics of different order and intensity.

Vitvarueffektivisering med hjälp av värmelagring : Simuleringsstudie kring energiförsörjning av vitvaror med hjälp av värmepump & ackumulatortank

The constant need of energy is something that affects us all no matter our current situation. Whether we are driving our car to work, taking the elevator or using the oven to cook dinner we end up relying on energy. Our whole society is continuously striving to achieve a higher grade of efficiency and the process of supplying ourselves with energy is no exception. The importance of appliances in our everyday life cannot be exaggerated and thus the importance of their high efficiency.Efficiency is already a keyword in the appliance industry with labels, stars and numbers helping us choosing the most suitable option for the task ahead. No matter how efficient appliances often use pure electricity as their energy source.

1 Nästa sida ->