Sökresultat:
3605 Uppsatser om Water treatment plant - Sida 2 av 241
Kraven på ägare till minireningsverk skiljer sig åt mellan olika kommuner
Discharge of inadequately treated waste water containing nutrients such as phosphorus and nitrogen as well as organic matter and bacteria is associated with a risk of eutrophication and contamination. The Swedish government has decided upon several Environmental Quality Objectives aiming to reduce the emissions of nutrients to water bodies.In Sweden, there are between 675 000 to 1 000 000 on-site sewage systems. Recent studies have shown that the function of small sewage treatment plants is in many cases insufficient. To prevent this regular service and supervision by a professional is needed. The focus of this study are small sewage treatment plants which use a technique where mechanical, chemical and/or biological reduction of pollutants is being used in the same facility to reduce nutrients in household wastewater.The aim of the study is to investigate how different municipalities ensure that small sewage treatment plants fulfill the requirements and reduce pollutants as efficient as the manufacturers claim.
Vattenkvalitet och risker vid ändrat intag för vattenförsörjning i Västerås
Water is the most essential resource for life. In cases where drinking water is processed from surface water it is important to ensure the raw water is of good quality, and is suitable for processing through the Water treatment plant.The drinking water for Västerås is sourced from Västeråsfjärden, in the western side of Lake Mälaren. The city itself is home to marinas, ports, a wasteWater treatment plant, the Svartån outlet, sewage pumping stations and stormwater outlets. Because of the negative effects these activities have on surface water quality, Mälarenergi AB is interested in relocating the raw water intake point to Granfjärden, 10 km east of Västeråsfjärden. At Granfjärden the intake point would be less exposed to the activities in Västerås, and could be placed at a greater depth, resulting in better water quality.In this Master?s thesis the water quality and the pollution risks at Västeråsfjärden and Granfjärden sites are compared.
Miljö- och hälsoskyddskontorets tillsynsarbete - ur verksamhetsövarens perspektiv
Nanofiltration is a proper way of preparation of drinking water. The process has a lot in common with reverse osmosis where a semipermeable membrane is used to separate a pure water flow from the remaining water. A pilot plant was used to ensure that nanofiltration is a suitable technology for a specific waterworks station in Glemmingebro, Ystad. The purpose was also to find out if a pH-adjustment is needed for feed water in a possible full scale plant. In this case nanofiltration is used mainly to remove sulphate and calcium since the raw water contains concentrations of these substances which exceed the limits for potable water. It is important to receive a high recovery (RC), otherwise the deliviery of water won?t be high enough.
Total organic carbon (TOC) and chemical oxygen demand (COD) - Monitoring of organic pollutants in wastewater
Total organic carbon (TOC) and chemical oxygen demand (COD) are two methods used for measuring organic pollutants in wastewater. Both methods are widely used but the COD method results in production of hazardous wastes, including mercury.The purpose of this study was to validate the method TOC that will replace COD and find a factor to convert TOC to COD. In this study 26 samples were analyzed from four sewage treatment plant in the municipality of Enköping.The results show that the COD method could be replaced by the TOC method.The factor for COD/TOC was between 3.1 - 3.3. Both methods will be used in parallel until 2013 when it will be forbidden to use the COD analysis..
Jämförelse mellan våtkompostering och andra VA-system i omvandlingsområden : en fallstudie i Norrtälje kommun.
Eutrophication of the Baltic Sea and Swedish lakes remains a major problem despite many years of effort to reduce the emissions of nutrients. One major source is waste water systems, especially private sewage systems. These sewages accounts for a very large share of nutrients per capita in comparison with citizens connected to larger sewage treatment plants. Norrtälje community has the greatest number of private sewage systems in Sweden. Discharges of nutrients, especially phosphorus, to the Baltic Sea from these sewage systems are significant.
Avloppsvattenbehandling med membranbioreaktor : En jämförande systemanalys avseende exergi, miljöpåverkan samt återföring av närsalter
In the pilot plant at Hammarby Sjöstad, Sjöstadsverket, several new methods are tested in order to achieve a good use of resources. When a new technique is considered it is often the performance of the technique itself, under given conditions, that is evaluated. However, in order to evaluate the overall function the whole picture is needed. With a system analysis it becomes possible to make a comparison where all the positive aspects are put up against the negative ones, for the technique itself as well as its requirements. In this way the influence that minor components have on an entire system can be considered.This report presents a system analysis of an anaerobic membrane reactor (MBR) with a VSEP-membrane (Vibratory Shear Enhanced Process).
Utredning av potentiella hälsorisker i samband med slagg- och slaggvattenhantering vid Hedenverket, Karlstad
In this study potential health risks for employees in connection with handling of bottom ash and bottom ash water at a Municipal Waste Incineration (MWI) plant have been investigated. Air surrounding the bottom ash and the bottom ash water has been examined. MWI is one of the primary ways to manage solid household waste, and bottom ash is the main solid residue produced by the incineration process. Bottom ash constitutes about 15-20% of the original waste. The bottom ash is extinguished in a water bath (bottom ash water).The study was carried out in a MWI plant in Karlstad, Sweden.
Skillnader i vatten- och avloppshantering inom EU : En jämförelse mellan Slovakien och Sverige
The management of water resources and waste water varies between the countries of the EU. For many years, a large part of the water in Europe has been contaminated by, among other things, insufficiently treated waste water and emissions from agriculture. The EU Water Framework Directive 2000/60/EC and the Urban Waste Water Directive 91/271/EEC are intended to harmonize fresh-water management and waste water management within the whole EU, aiming at safeguarding drinking water of good quality and a high quality of all water within the EU today and in the future. There are however some problems concerning the waste-water directive. One problem is the huge investment needed in Slovakia to fulfil the demands of the waste-water directive for waste-water management in larger communities (with more than 2000 inhabitants).
Uthållig sanitet : en förstudie i staden Picota, Peru
The access to good sanitary facilities is an important factor that elevates the experienced living standard as it improves hygiene and reduces the transmission of deseases. The ratification of the millennium goals by 189 countries demonstrates that this is an important international issue. Together the countries have taken upon themselves that the proportion of the population that lacked access to sustainable safe drinking water and sanitary facilities in the year 2000 will have been reduced by half by the year 2015.
In Peru, the construction of sewage pipe networks to transport the sewage out of the direct human environment is progressing. The safety and sustainability of these systems can be questioned, since in Peru the sewage seldom receive any treatment before being emitted to a recipient. This is taking place in Picota and sorrunding villages as well.
In the last 25 years several systems implementing small-scale onsite treatment have been introduced throughout Latin America in an attempt to give more people access to sustainable and safe sanitary facilities, reducing water consumption and taking advantage of the agricultural values of the sewage fractions while protecting the environment from its negative impact.
In this study three different sanitary systems and the effects of different population growths were compared.
Vattenlogistik vid stubbehandling i slutavverkning
Water logistics has long been a problem in order to effectively carry out stump treatment in both thinning and final felling. It is important that the stump treatment?
equipment is configured as well as a sufficient amount of water is carried out on the harvester to get a cost? effective treatment. The flow control of the equipment has improved and water can be dispensed more efficient, but still the amount of water on the machine is a crucial factor in the total cost estimate.
The knowledge of the tools available to bring water as well as the internal logistics of loading and transport to the felling site is deficient. Increased focus on "smart" solutions to manage water cost is of great importance in order to combat Hetrobasidion spp in both thinning and final felling.
The purpose of the study is to describe and summarize different solutions of water logistics at stump treatment in final felling.
Ombyggnation, från sågverkslokal till restaurang. antonio ziakoulis
Pharmaceuticals that are found in marine ecosystems are a threatening environmental concern, which is known to harm both animal and plant life. One of the reasons for this problem is that the waste water treatment techniques are not optimized to clear waste water from its pharmaceuticals contain. In this master thesis four Swedish treatment wetlands were studied, and their ability to reduce numerous pharmaceuticals in waste water. The four treatment wetlands that were studied were those in Oxelösund, Trosa, Nynäshamn and Eskilstuna. Two ecotoxicological tests and chemical analysis were used.
Stump treatment with the root rot antagonist phlebiopsis gigantea : - sensitivity of P. gigantea spores to high pressure stress; - reduced water consumption for stump treatment
Stump treatment today requires large quantities of clean water mixed with the protective product Rotstop, to fully cover the stump surface. In order to reduce the
water consumption without reducing the coverage of the stump surface, the pressure in the stump treatment device can be increased. Therefore, the Phlebiopsis gigantea
(Fr.) Jül. suspension used as a biological control agent to prevent Heterobasidion annosum (Fr.) Bref. infection was pressure-tested.
Behandlingsvåtmarkers reningseffekt på aktiva läkemedelssubstanser under vinterförhållanden : En studie av fyra svenska våtmarker för avloppsrening
Pharmaceuticals that are found in marine ecosystems are a threatening environmental concern, which is known to harm both animal and plant life. One of the reasons for this problem is that the waste water treatment techniques are not optimized to clear waste water from its pharmaceuticals contain. In this master thesis four Swedish treatment wetlands were studied, and their ability to reduce numerous pharmaceuticals in waste water. The four treatment wetlands that were studied were those in Oxelösund, Trosa, Nynäshamn and Eskilstuna. Two ecotoxicological tests and chemical analysis were used.
Tjänligt vatten i kranen - Membranteknik gör det möjligt : En utredning av pilotförsök i Glemmingebro
Nanofiltration is a proper way of preparation of drinking water. The process has a lot in common with reverse osmosis where a semipermeable membrane is used to separate a pure water flow from the remaining water. A pilot plant was used to ensure that nanofiltration is a suitable technology for a specific waterworks station in Glemmingebro, Ystad. The purpose was also to find out if a pH-adjustment is needed for feed water in a possible full scale plant. In this case nanofiltration is used mainly to remove sulphate and calcium since the raw water contains concentrations of these substances which exceed the limits for potable water. It is important to receive a high recovery (RC), otherwise the deliviery of water won?t be high enough.
Energieffektivisering av färskvattensystemet på Skärblacka pappersbruk
The purpose of this master thesis was to study the water system for mechanically cleaned water at Skärblacka mill, in order to find and evaluate possibilities of using energy more efficiently. The thesis also includes an evaluation of the software tool ?Pumpanalys?Skärblacka mill produces pulp and paper. The large amount of water required is cleaned mechanically through filters and called mechanically cleaned water (MR0). The MR0 water is pumped out to the factory by four crude water pumps.