Sök:

Sökresultat:

2003 Uppsatser om Wastewater treatment - Sida 2 av 134

Industriella avloppsvatten i Chile : Identifiering av problem samt förslag på åtgärder

Chile and Santiago are struggling with heavy environmental problems as a consequence of urbanisation and industrialisation. In the Santiago region the air is seriously contaminated and most of the rivers are classified as heavily polluted.The aim of this thesis is to survey the industrial fluid waste situation in the Santiago region and to make suggestions on technological improvements or process changes. The purpose is also to study five different enterprises more closely and to give more detailed suggestions for improvement. Another purpose is to summarize relevant Chilean legislation.Information, provided by the supervisory authority, about the release of industrial wastewater to rivers has been analysed. Deep interviews have been made with authorities and consultants.

Cleaning process of abattoir wastewater with focus on bacterial pathogens

This study was conducted at the City Abattoir in Kampala, Uganda to evaluate the cleaning process, with focus on bacterial pathogens, in a pilot scale integrated bioprocess. This consisted of four steps: anaerobic sequencing batch reactors; aerobic/anoxic sequencing batch reactors; a high performance temperature controlled methanogenesis digester and a constructed wetland. The objective was to determine if this type of cleaning process could be used to clean wastewater from abattoirs in a satisfactory way. The indicator organisms for faecal contamination, Escherichia coli and Enterococcus spp. were used to investigate in what numbers bacteria could be found in the untreated wastewater and how much that was reduced in the different steps of the cleaning process. The water was analysed for Salmonella to see if human pathogens could be found and could survive the different steps of the treatment process.

Textilindustrins avloppsvatten och avloppsslam ur ett miljöperspektiv : Underlag för internationella riktlinjer inom projektet Sweden Textile Water Initiative

The aim of my thesis is to obtain knowledge of textile wastewater and textile sludge from an environmental perspective, which can be used as a basis for the  ?Sweden Textile Water Initiative? guidelines for a sustainable sludge management. In my study I have mainly focused on textile dyes, salts and metals and their routes during Wastewater treatment.This paper is partly a literature review, which I began by identifying the pollutants discharged from each textile process. Then I studied wastewater and sludge quality, environmental aspects, possible treatment and recycling methods. I have also tried to find existing type of guidelines in order to make comparisons.

Kemisk karaktärisering samt nedbrytning av process- och avloppsvatten vid SCA Ortvikens pappersbruk

During pulp and papermaking process a huge amount of water is used. The wastewater contains a large amount of pollutants and has to be treated before it reaches the recipient. In March 2004 a new bleaching plant was started up at SCA Graphic Sundsvall AB, Ortviken?s paper mill using peroxide. The production of bleached thermo mechanical pulp and thus the load to the wastewater plant increased.

Närsaltsdosering till luftad damm : en åtgärd för ökad TOC-reduktion hos Skoghalls Bruk luftade damm

In the process of making carton boards into Skoghall Mill, are great quantities of water being contaminated. This water has to be treated before it is possible to release into the recipient, Kattfjorden. One of the contaminations that is important to extract from the wastewater, is organic carbon (measured as TOC-total organic carbon) because microbiological breakdown can lead to the bottom becomig free of oxygen.The Wastewater treatment at Skoghall Mill is done through an external Wastewater treatment that is located at the factory. The biological treatment (aerated lagoon) is a 140 000 m3 water pool with surface aerator, which is give oxygen to the water. In the lagoon live microorganisms who performs the biggest part of the TOC-reduction.One problem with the lagoon is that the treatment of TOC is considerably worse during wintertime than during summertime.

Hydrolys av primärslam för förbättrande av biologisk fosforreduktion vid behandling av hushållsavloppsvatten [Hydrolysis of primary sludge for enhancement of biological phosphorus removal in household wastewater]

Hammarby Sjöstad is a new district of southern Stockholm built with focus on reduced environmental impact by recirculation of materials and sustainability. The environmental goals aim to cut the water consumption by half and a separate storm water treatment. Thus, the wastewater will be more concentrated and will originate from the households only. The Sjöstad project includes the idea of a local treatment plant for the household wastewater. To evaluate this possibility, Sjöstadsverket, an experimental treatment plant was constructed.

Kraven på ägare till minireningsverk skiljer sig åt mellan olika kommuner

Discharge of inadequately treated waste water containing nutrients such as phosphorus and nitrogen as well as organic matter and bacteria is associated with a risk of eutrophication and contamination. The Swedish government has decided upon several Environmental Quality Objectives aiming to reduce the emissions of nutrients to water bodies.In Sweden, there are between 675 000 to 1 000 000 on-site sewage systems. Recent studies have shown that the function of small sewage treatment plants is in many cases insufficient. To prevent this regular service and supervision by a professional is needed. The focus of this study are small sewage treatment plants which use a technique where mechanical, chemical and/or biological reduction of pollutants is being used in the same facility to reduce nutrients in household wastewater.The aim of the study is to investigate how different municipalities ensure that small sewage treatment plants fulfill the requirements and reduce pollutants as efficient as the manufacturers claim.

Återvinning av näringsämnen från hushållsspillvatten med omvänd osmos

Hammarby Sjöstad is a new district in Stockholm with high environmental standard. Stockholm Water Company evaluates a local Wastewater treatment plant with cutting edge technology. The first step is an experimental treatment plant (Sjöstadsverket) with four parallel lines of treatment, each with a capacity to treat wastewater from 150 persons. Within the membrane technology subproject the possibility of using reverse osmosis (usually called RO) to regain nutrients is examined.Reverse osmosis separates the incoming water in a clean permeate and a concentrate that, as the name indicates, is a more concentrated version of the incoming water. Using this method in Wastewater treatment, a solution high in nutrients can be obtained without the use of chemical precipitation agent and with no production of sludge.

Optimering av biologisk fosfor och kvävereduktion i ett reningsverk för hushållsspillvatten

In connection with Henriksdals Wastewater treatment plant (WWTP) a smaller plant is situated called Sjöstadsverket where new methods for Wastewater treatment are tested and evaluated in different process lines. On one of the lines experiments with enhanced biological phosphorous removal (EBPR), have been carried out to evaluate if it is a good alternative to traditional chemical phosphorus removal. This thesis evaluates the results from the experiments conducted during fall 2005.The incoming water from Hammarby Sjöstad consists of only household wastewater, which gives a wastewater with high concentrations of nutrients and organic carbon. This is partly positive, because one of the limiting factors for effective biological phosphorus removal is the lack of easily biodegradable organic carbon. The high concentrations of ammonium and phosphorus demand a high reduction to achieve the requirements of outgoing concentration.To optimize the process experiments with different recirculations and different aeration techniques have been made.

Spårning av miljöstörande ämnen i Uppsala stads spillvattennät

To the sewer systems households, industries and other activities are connected. The wastewater is collected at treatment plants where a nutritious sludge is produced. The sludge does not only contain nutrients, but also hazardous substances originating from different activities in society. To reduce the flow of hazardous substances to treatment plants and to create a sustainable recycling of plant nutrients the Swedish Water & Wastewater Association has developed the certificate system REVAQ. This certificate requires a good quality of the sludge but also that the treatment plants maps the origin of the unwanted substances.

Källsorterade systems påverkan på avloppsreningsverk : växthusgaser, energi- och resursanvändning i modellstudie

The aim of this study was to evaluate the effects on a simulated wastewater plant regarding GHG emissions and use of energy and resources when implementing source separated wastewater systems. The effects were studied for different restrictions of effluent quality and for different temperatures on the influent. The simulation model BSM2G calibrated for Käppala Wastewater treatment plant was used. The task was executed by simulating nine different scenarios with an increase in influent load from new connections equivalent to 3, 10 and 30 % of the present connections. These new connections were served by conventional, urine separated or black water separated systems.

Avloppsvattenbehandling med membranbioreaktor : En jämförande systemanalys avseende exergi, miljöpåverkan samt återföring av närsalter

In the pilot plant at Hammarby Sjöstad, Sjöstadsverket, several new methods are tested in order to achieve a good use of resources. When a new technique is considered it is often the performance of the technique itself, under given conditions, that is evaluated. However, in order to evaluate the overall function the whole picture is needed. With a system analysis it becomes possible to make a comparison where all the positive aspects are put up against the negative ones, for the technique itself as well as its requirements. In this way the influence that minor components have on an entire system can be considered.This report presents a system analysis of an anaerobic membrane reactor (MBR) with a VSEP-membrane (Vibratory Shear Enhanced Process).

Små vatten- och avloppssystem : Möjligheter till inskränkning av verksamhtesområden

This study is focused on small scale water and wastewater handling in Sweden. The study is divided into two major parts; the first describes common methods for water- and wastewater handling and the second part is a case study on three small and expensive systems in Gällivare municipality, in the north of Sweden. In the case study, abilitys for the local government to hand over unwanted systems to the water users is investigated and found to be a plausible solution to cut costs for two out of the three studied systems. In the third case, water and wastewater systems is not recommended to be handed over but other ways of cutting costs are suggested..

Hydrauliken i Ångersjöns fosforfällor : bestämning av flödesvägar och åtgärdsförslag för optimal fosforbindning vid avloppsrening med reaktiva filter

Discharge of untreated wastewater leads to unnaturally high levels of nitrogen and phosphorus in rivers, lakes and the sea, which results in unbalanced ecosystems with eutrophication and lack of oxygen. Part of the phosphorus in surface waters is coming from on-site Wastewater treatment from scattered households with unsatisfactory purification. Blast furnace slag is a by-product from iron production, and has in laboratory trials showed good phosphorus binding capacity. To test blast furnace slag as a reactive filter media for phosphorus separation in a full scale experiment, a Wastewater treatment plant has been built behind the picnic area at Ångersjön alongside the road E4 in central-eastern Sweden. The plant contains two parallel lines, one with blast furnaces slag and the other with Filtralite-P as phosphorus sorbent. Both filters have showed decreasing phosphorus purification effect with time in spite of a low wastewater load.

Systemidentifiering och reglering av en luftningsbassäng på ett reningsverk

A Wastewater treatment plant has the task to refine the wastewater from substances that should not be released into the environment. The decomposition process can, in a simple way, be described as follows: micro-organisms breathe oxygen and eat unwanted substances. The environment in which the micro-organism lives is known as sludge and the correct amount of oxygen available in the sludge is important for the decomposition to be effective. The oxygenation of the sludge alone stands for about 30% of the plant?s energy consumption.

<- Föregående sida 2 Nästa sida ->