Skalkonstruktion : Med inriktning mot hållfasthet och dämpning av ljud
The sound part is mainly practical and is dependent on concepts that have been tested through measuring with a sound level meter. The design part is more theoretical and has been verified with CAD models and finite element analysis.With a sound damping hood on the compressor the sound level is reduced with up to four dB. An optimized absorbent for the compressor space gives a reduction with three dB. By using the insulation for the heat water tank as absorbent we can see a sound reduction on the lover octave bands. A reduction like this is elsewhere hard to achieve as at it requires thick absorbents.By changing the today?s insulation to the heat water tank to a form of polystyrene polymer insulation the weight from the heat pump above can be transferred to the stable heat water tank.
Energianalys av fastighet Brynäs 12:1 : Energikartläggning med effektiviseringsåtgärder inriktning mot ventilation
Energianva?ndningen i Sverige och va?rlden fo?rva?ntas o?ka och bostads- och servicesektorn sta?r fo?r 40 % av va?rldens totala energibehov. Det a?r viktigt att energieffektivisera redan befintliga byggnader och optimera dess system da? en la?gre energianva?ndning gynnar ba?de miljo?n och ekonomin. En byggnads ventilationssystem sta?r fo?r en stor del av en fastighets energianva?ndning och det finns ofta stor potential fo?r systemet att optimeras och effektiviseras.En fastighetsa?gare vill inte ha fastigheter som sta?r outhyrda.
Spillvärmeåtervinning
SAPA´s resource of waste heat is the basis for this thesis to investigate the possibility of energy assets in their cooling water and possible uses for it. The energy in the waste water is greater than the current need which has three uses which are (1) heating the factory, (2) converting liquid propane to propane gas and (3) local domestic heating. The average energy load that is available is 1, 7 MW and the average temperature in the cooling water is 41°C. The total energy load at dimensioning out side temperature is approximately 1,6 MW for the three current uses. The temperature is currently too low to be used directly in the existing systems so an upgrade is needed.
MIKROVÄRMEKRAFTVERK för hemmabruk
My questions at issue for this report has it´s beginning in the growing problems of thenegative effects of burning fossile fuels and the rapidly growing energyprices.1. Is it possible to design a micro scale powerplant?2. Is it economically interesting for a potential customer to by such a product?The aim with this report is therefor, with the help of design work and calculations, to answerthese questions and to create a platform for building a fully functional micro scale powerplant.The material used in the report is mostly product catalogs from various industries but alsostudy course littrature about steam engines.The result of the report is that it is fully possible to design a fully functional micro scalepower plant.
Potentialen av värmebesparing i ett avlopps luftningsledning
This thesis aims at determining the heat losses in a property vent stack and its roof valve. Upon request of a company, the vent stack is analysed for possible heat recovering solutions to be implemented, while relining of the drain system is executed and with a suitable payback time for the economic investments. The heat loss calculations are based on data for properties that are located in the Stockholm region, but also easy to change depending on the situation. The calculations are done on pipes made out of cast iron, which still is the most common type of drain pipe in Sweden, and these are the pipes that relining is usually made on. The calculations that needed to take several variables into account have been done in MatlabR2014a and the thermos dynamical properties that were used in those calculations have been extracted from EES.Three different types of heat losses in the vent stack have been taken into consideration in this thesis.
Redesign of an existing apartment block in Kv Preussen to passive house
Passive houses are a relatively new concept in Sweden and by that it is meant a house without a traditional heating system. The most acknowledged passive house project is the terrace houses in Lindås, Gothenburg, which we have used as a reference. This project concerns a square apartment block. So far, no square apartment block has been built as a passive house in Sweden.The common opinion in the construction industry is that it is not economical to build extremely energy efficient houses. With Peab as commissioner our task was to investigate if that is true, if regarding the construction of a multi storey house as a passive houseMidroc, now owned by Peab, constructed in the block of Preussen in Jönköping during 2004-2005 four houses, with 132 apartments distributed on seven floors.
Att bli varse det ordlösa : Psykoterapeutstudenters upplevelse av momentet spädbarnsobservation
The objective of this study is to understand how people with psychiatric diseases who are enrolled at a psychiatric clinic experience the recovery process and which internal motivations and external factors influence the process. The study is based on interviews with five people who have been enrolled at a psychiatric clinic. Another aim of the study is to understand how the importance of the outpatient care for the personal recovery and the improvement opportunities of the support from the rehabilitation unit that the interviewees see. The study is qualitative and abductive approach was chosen. This means that the study is based on empirical data supported by established theories.
Fjärrvärme, vad annars? : Fjärrvärme och dess alternativ
AbstractBackgroundThe Swedish district heat market of today is a subject being discussed regarding the reasonableness of the heat district supplier?s price settings. The issue is currently on a government level where a new investigation is being executed at the time of writing. Many real estate owners are growing tired of the situation where the heat district suppliers are taking advantage of their monopoly position, thus feeling that the price of district heating has been increasing far too much for many years. The market can be described as a natural monopoly because the real estate owner has no possibility to choose another supplier if they are unsatisfied with the present.
Klimatsimulering av ett kontorsrum : Hur de termiska stigkrafterna påverkar ventilationseffektiviteten
AbstractIn urban societies people spend more and more time indoors, which put great demands on the indoor environment. If the ventilation is to manage the removal of unwanted substances in the indoor air, a good mixing of the air is required. The question arises that, whether the buoyancy forces will counteract a good mixing of the indoor air or not?This report aims to clear up the difficulties whether you need to consider the buoyancy forces or not, when adjusting a ventilation unit. For studying the indoor mixing of the air a two dimensional model is constructed in COMSOL Multiphysics.
Det energiproducerande huset
We are heading towards a huge switch of how energy is produced with fossil fuels being replaced by renewable energy sources. It is not difficult to replace the energy you use in the house and there is no need for futuristic technology. There are already many established products on the market such as high efficiency vacuum solar collectors, heat pumps & small wind power stations that can supply the energy being used in a house. The company Sol & Energiteknik SE AB in Huskvarna has many different products which can reduce the need for an outside energy distributor. An average house in Sweden uses 15 000 kWh for heating, 5000 kWh for tap water and 5000 kWh for electricity.
Termisk analys av kompakta jordvärmesystem - Sensitivitetsanalys och korrektions faktorer baserat på fältmätningar i referensanläggningar i Östergötland
Chapter 1 defines the aim of the project and gives a general orientation about ground heat extractors. In chapter 2 physical processes that could be expected to be involved in the heat transport around a ground heat exchanger are discussed. It is shown from a literature study what amount of moisture transport due to thermal gradients there could be expected in a ground heat exchanger. The conclusion is drawn that the moisture gradient (Sr) is of same magnitude as the driving temperature gradient (°C). At the expected amount of increased moisture around the pipes the moisture transport could be considered to have a little effect on the brine temperature.
X-heat, hanteringsutrustning för gipsrullar
En hanteringsutrustning för att underlätta förberedelser av gips på sjukhus.
Primärenergianvändning av passivhus i Sverige : Med fokus på Kvarteret Trettondagen
The building sector accounted for around a fourth of the total energy usage in Sweden in year 2010 (Energimyndigheten, 2012). Therefore it has become very interesting to achieve a lower energy usage in residential buildings. One way to achieve that is to build so called passive houses. By being very well insulated and have low leakage through the walls, they can reduce the energy usage for heating with a substantial amount. The first passive house was built during the 90?s in Germany; and in Sweden the first passive house was built in Gothenburg 2001.
Studie av Karlskogas fjärrvärmenät för att sänka returtemperaturen
A district heating plant has the advantage that it can take advantage of the waste heat from industries and use of cheap fuels to produce heat. But for the long term is competitive requires that energy is also saved in district heating plants. One way to save energy in a district heating system is to increasing cooling to the return temperature. This leads to less power needed to drive the distribution pumps, and that more energy could be extracted from the same amount of fuel by an improved flue gas condensation.In Karlskoga the return temperature into the district heating plant is high. They would therefore reduce the return temperature in order to extract more energy from the flue gases.
En flödesutjämnande driftstrategi för Uppsalas fjärrvärmesystem : En ändrad styrning av framtemperaturen
This thesis examines a possible control strategy to minimize flow fluctuations in Uppsala?s district heating system. High variations in flow rate may lead to complications caused by hydraulic constraints in the district heating system. These complications, such as inadequate pressure and temperature levels, increase the risk of heat delivery failures. It is therefore important to avoid such situations both for the producer and for the customers.Typically, the forward temperature is controlled by using a rough correlation with respect to the outdoor temperature.