Sök:

Sökresultat:

227 Uppsatser om Thermal cracks - Sida 14 av 16

Uppvärmd konstgräsplan : Beräkning av utnyttjningstid för en uppvärmd konstgräplan med alternativa rörplaceringar

For Skattkärr IF a turf field with warming has been projected to increase field?s utilization hours and to have a longer period for athletes to perform their activities outdoors. The technique chosen to heat the plan is a type of a geothermal heating system without a heat pump. The brine, which is water with 30% ethanol, collects heat from the borehole and discharges it to a coil in the field. There is at position 11 boreholes but it is planned to increase the number to 31, which is the design for the facility.

Hydraulisk och termisk grundvattenmodellering av ett geoenergilager i Stockholmsåsen

Geothermal energy can be extracted from an aquifer, where the groundwater is used as heatexchange medium while heat and cold are stored in the surrounding material in the aquiferand to some extent in the groundwater. Application of aquifer storage for the use ofgeothermal energy is mainly used in large scale facilities and is limited to sites with suitableaquifers in the form of ridges, sandstone and limestone aquifers.Löwenströmska hospital in the municipality of Upplands Väsby, north of Stockholm, islocated nearby the northern part of the Stockholm esker. This means that it can be profitableand environmentally beneficial for the hospital to examine the possibilities of aquifer storagein the esker material next to its property.The purpose of this master thesis has been to investigate if geothermal energy storage with aseasonal storage of heat and cold can be applied within Löwenströmska hospital?s propertyarea using groundwater modeling. A hydraulic groundwater model was constructed inMODFLOW based on a simplified conceptual model of the groundwater system.

Inneklimatet på ett kontor : Undersökning av inneklimatet vån. G4 stadshuset samt kontor på Ånghammargatan

This report describes an investigation of the indoor climate in two different workspaces. Since we a big part of our lives are staying indoors in artificial environments, and more particularly in our workplaces, we think it would be interesting to do this investigation. The technical solutions for air treatment systems began with simple natural systems without fans and where the thermal rise of the air applied. In modern time is technical air treating systems used to take care of the fresh air supply. This type of units can supply filtered air with the right temperature to the building. Well-functioning ventilation is essential to bring clean fresh air to the room and effectively remove impurities without sound- or draught problems. The indoor climate is relevant for the output capacity.

Inventering och bedömning av förorenade områden inom division Energi, Tekniska Verken i Linköping

This thesis was commissioned by Tekniska verken, Energy Division with the overall aim to investigate the concept of environmental debt and what it means for a business. Furthermore, a sustainable risk and responsibility investigation shall be carried out on the concerned areas. Finally, the priority areas shall be highlighted and proposed actions presented. The Swedish Environmental debt concept was presented in 1992 by Arne Jarnelöv. Environmental debt is defined as restoration costs for environmental damage. In the early days the concept did not take into account who was responsible, but the environmental debts was regarded as a humanity debt to future generations.

ENERGIEFFEKTIVISERING? Av lamellhus byggt på sextiotalet

TitleEnergy-efficiency ? of slab blocks built in the sixtiesAuthorsRichard Sandahl and Kim SöderbergEducationHalmstad University, Section for economy and technique Construction Engineering 180 ECTSSupervisorMargaretha Borgström, Universitylector construction physics, Halmstad UniversityContact person at HFABUlf Johansson Heating, sanitation and energy co-ordinatorReportExamination paper at the construction engineering program is performed in cooperation with HFAB (Halmstad real estate concern Inc.)AimThis examinations work is done in cooperation with HFAB and there project on the block around the street Maratonvägen. HFAB:s dwelling stock on this area are going through a bigger renovation and in relation to this they are looking on the possibilities to make this building more energy efficient. That is why this examination paper has as purpose to answer the question if it is possible to make slab blocks built in the sixties more energy efficient. This is done by calculate energy efficient measures on a chosen apartment block at Maratonvägen in Halmstad, in an energy and expense perspective.MethodThe examination paper is based on different methods, mainly calculation but also qualitative conversation studies, economic calculations and literature studies.

Energi- och kostnadseffektiva klimatskal : För lager-, industri- och kontorsbyggnader

A study to optimize insulation thickness for stock-, industrial- and office-buildings for external walls and roof in an economical perspective has been conducted on behalf of DynaMate. DynaMate?s role is to maintain all Scania?s buildings. Analysis has also included other parts of the building envelope, such as windows, exterior doors and industrial doors. In this thesis, three different types of exterior wall constructions has been investigated, these are a sandwich design consisting of sheet metal and a another one consisting of concrete, as well as a wall of concrete with a coating of plasters.

Energianvändning för markkonstruktioner förlagda med ytvärme : En teknisk och ekonomisk utredning av fördelarna med att isolera under värmerören

The need for snow-free surfaces at squares, bus stops, platforms, car parks and sports facilities increases and at the same time energy price rise and the environment is becoming a hotter issue. The construction of the ground heating systems often lack thermal insulation under the heating pipes, which means that the heat from the pipes not only warm up the soil surface but also heats the surrounding soil. The insulation also has more features, by insulating the risk of frost damage is minimized. The goal of this report is to demonstrate the large heat loss and energy costs in the absence of insulation under the heating system.The report begins with a scientific way to study and treating the soil heating system uses, and the theory involved. Furthermore it also deals with different routing principles of heat pipes depending on the facility.All calculations are made with so called finite element method (FEM), in COMSOL Multiphysics 3,5a, where models are created with different conditions.

Smarta lokala energisystem, Vision-Teknik-Tillämpning

The energy sector is facing an impending paradigm shift. Today?s technology enables the end-user to generate their own energy locally at home. Furthermore, recently developed storage technologies make it possible to balance energy demand with stored energy and integrate district heating with the local power grid. This means that in the future heat and electric power will interact and energy flows is converted over energy boundaries.

Vedrötor i stadsträd : biologi, detektionsmetoder och förebyggande åtgärder

Urban trees have very little in common with trees on natural sites, such as forests or pastures. Trees in urban environments are often planted in packed soil and in small volumes. This can lead to decreased availability of water and oxygen, as well as deteriorated ability for the soil to store nutritional elements. Also above ground the tree usually have limited space in cities. Regulations on free height over roads and cycle tracks demands high stems at an early stage of their development.

Utredning av solenergi för drivning av sorptiv kylprocess för inomhusluften på Stockholmsarenan

Cooling down the indoor air can be done in several ways. One way is desiccantcooling which will be used at the Stockholm Arena. This method is used in airhandling units that use temperature changes and moisture fluctuations in the air. Oneof the steps is to add heat during the cooling process in order to reduce the relativehumidity of the exhaust air. The air passes thru an adsorptions rotor which thenabsorbs moisture from the supply air.

RENOVERING AV MILJONPROGRAMMET TILL PASSIVHUS : Implementering av tysk prefabteknik

Construction accounts for about 35 percent of the total Swedish energy consumption and most of the energy is used by the large housing stock from the so-called ?Million program?. In the national action plan the government has put forward in energy efficiency. It is mentioned that existing buildings account for more than 90 percent of what is expected to be the housing stock within the coming 50 years. In order to meet environmental objectives its required that the existing stock be reviewed for energy efficiency. The goverment is now initiating a national framework with a budget of SEK 300 million Swedish crowns per year for five years, starting in 2010 to achieve the goal on energy efficient buildings. Energy efficiency of buildings in both new construction and above all within the existing stock are addressed.

Salmonella prevalence in the poultry feed industry in Pakistan

Abstract One of the leading causes of food borne infections in the world is due to Salmonella by con-suming poultry products including eggs and meat. According to US Food and Drug Admin-istration (2009), 2 to 4 million cases of Salmonellosis in humans occur every year only in US. Salmonella causes wide range of diseases with enteric and typhoid fever, food poisoning, di-arrhea and gastro-enteritis. Many serotypes of Salmonella do not have host specificity and cause disease in all kinds of animals and humans. Salmonella has capability to modify accord-ing to the changing environment and it can develop resistance against routine elimination practices of sanitation, chemical treatments and antibacterial drugs. Newly established poultry industries in Pakistan are confronting various infectious diseases including Salmonellosis while in Sweden Salmonella prevalence in animal products con-sumed for humans is extremely low.

EN TOTALKOSTNADSJÄMFÖRELSE MELLAN CELL-, SKUM- OCH LECA-BETONG

This report provides a comparison between the products cellular concrete, foam concrete and LECA concrete. The questions to be answered during the work is how the cellular concrete stands up in cost terms to the existing competitors on the market, how the concrete products differ in design work, and in which situations the concrete varieties are preferred to use.Cellular concrete is a variant of ordinary concrete, with the difference that the ballast is exchanged from stone materials to expanded polystyrene beads (EPS). This substitution gives a product with higher insulation values but lower weight than ordinary concrete.The work was carried out by designing a survey which was sent to two hundred randomly chosen companies across Sweden, to see the building industry?s opinion of the product cellular concrete. The survey showed that cellular concrete was equals its competitors in terms of price, while the product was said to be more flexible, quicker and easier to cast.Then some of the companies, who participated in the survey, were interviewed to see more carefully, how the price, the workmanship and the time for casting and dehydration differed between the products.

Latent värmelagring i vattenburet uppvärmningssystem med elpanna för byggnadsapplikationer

Latent heat storage is a way to store thermal energy when a phase change material undergoes a phase change. The advantage of latent heat storage is the capability to store more energy per mass unit than other heat storage methods. The most commonly used phase change in latent heat storage is the transition between solid and liquid. Phase change materials can be divided into organics, inorganics and eutectics.In the Nordic electricity market the price of electricity is set every hour by Nordpool spot, which leads to price fluctuations because of changes in demand. The main goal of this report is to create a latent heat storage system in a single-family home and investigate the possibility to save money by charging the latent heat storage system when the price of electricity is low, and discharge when the price is high.The thermodynamic model consisted of a ?tube-in-tube? heat exchanger with phase change material in the outer tube and water as the heat transfer fluid in the inner tube.

COMSOL Multiphysics - Ett energitekniskt analysverktyg vid numerisk simulering av köldbryggor och analys av fukt i konstruktionesdetaljer

Berggren, O. (2014) COMSOL Multiphysics ? Ett energitekniskt analysverktyg vid numerisk simulering av köldbryggor och analys av fukt i konstruktionsdetaljer. Examensuppsats i ämnet energiteknik. Institutionen för tillämpad elektronik och fysik vid Umeå Universitet.Konsultföretaget Tyréns har vid sitt kontor i Umeå önskat att utvärdera tillämpningen av programvaran COMSOL Multiphysics.

<- Föregående sida 14 Nästa sida ->