Sökresultat:
1133 Uppsatser om Temperature response - Sida 13 av 76
Betongpelare och brand : En utvärdering av 500 °C isotermmetoden
At the beginning of 2011, Sweden started using the European rules for structural design, the Eurocodes, instead of the previous national rules. In both the previous rules and the Eurocodes, it is possible to dimension concrete columns using tabled values. However, the required cross section measurements have increased considerably. Moreover, it is possible to dimension concrete columns using calculations, however, this is unusual.The development of a fire in a fire cell can be divided into the growth stage, the fully developed fire and the cooling phase. The duration of each phase, as well as the temperature, is dependent on a number of factors, e.g.
?Det är böcker som är meningen med ett bibliotek?: Hur bibliotekarien i barn- och ungdomslitteraturen bemöter användare.
The aim of this Master?s thesis is to examine the librarians? perception of the users of children?s and young people?s literature. Questions posed in this study are: How are the librarians described according to appearance, personality and interaction with the users? How are the librarians described compared to former studies on the subject? Which perception can be seen, based on Douglas Rabers?s theory which describes the role the public libraries can take in the society? The study is based on content analysis. We have examined 15 descriptions of librarians in both picture books and literature for young adults, published between 1985 and 2006.
Cytokinuttryck vid vaccination med olika vaccinkoncept mot FIP :
Feline infectious peritonitis (FIP) is a feline viral disease with high mortality. There is no cure or any effective vaccine available today. Many questions are yet to be answered about this disease and the immune response in affected cats.
The aim of the study is to evaluate two different techniques for the study of cytokine profiles in cats vaccinated with a vaccine concept against FIPV. More information about the immune response in these cats could give valuable information to better understand the pathogenesis of the disease and the development of an effective vaccine.
Hanteringsmetoder av reptiler på djursjukhus med hänsyn till stress och skaderisker
It is popular to keep reptiles as pets in Swedish households. The number of households reporting reptile ownership is more than 15 000 (SCB, 2006). This means that a veterinary practice should consider how to take care of reptiles as patients.
The aim of this study was to examine literature and studies concerning safe handling and restraint of reptiles as well as the effects of acute and long term stress response and to suggest a simplified plan for handling reptiles in a veterinary practice.
The result of literary studies is that common recommendations for safe handling and restraint of reptiles is based on old techniques and experiences from safe handling of wild animals. The main concern is safety for the veterinary nurse and for the reptile.
Stress studies indicate that acute stress response is not harmful for the animal i long term. On the other hand studies of the effect of prolonged stress are not conclusive.
Effektivisering av lagringsplatser. Ett förbättringsprojekt på Mekpart AB
Aeroseum is an aviation museum located in an old military underground hangar. The ventilation system in the hangar is designed for the military purpose of the hangar. This design includes a solution with air flowing through the space between the construction of the hangar and the rock surface. The solution is intended to avoid a buildup of inflammable gases. This design leads too high humidity levels in the hangar.
Jämförelse av resultat mellan manuell gelkortsanalys och automatisk immunohematologisk gelkortsanalys vid utförande av blodgruppskontroll och antikroppsscreening (BAS-test)
Incompatibility between donors and recipients can cause fatal hemolytic transfusion reactions (HTR), kidney damage and death and immunization of the recipient. Antigens on the surface of erythrocytes in the ABO blood group system and regular natural antibodies against these in the patient?s plasma must be considered. An individual always has a corresponding antibody of IgM in their plasma. Irregular antibodies acquired by transfusion or pregnancy and active in body temperature also cause the HTR incompatibility.
Oljetemperaturens inverkan på motoroljans degradering i lastbil
The market for heavy duty engines is constantly requiring engines that should be more andmore powerful, while still maintaining low fuel consumption. As a result of increasing enginepower, the engine and coolant temperature increases as well due to insufficient coolingperformance (because of design issues, cost etc.).Also, emission legislations, both current and future, require more and more measures to betaken by engine manufacturers. One way of meeting the legislations is the use of cooled EGR(Exhaust Gas Recirculation), which also lead to increased coolant temperatures.Both these factors also naturally lead to increased engine oil temperatures, the consequencesof which are not thoroughly investigated.This thesis project aims to investigate effects of high temperatures on engine oil degradation,with focus on the greatest degradation process: oxidation. To do this several engine runs havebeen performed on a 310 hp engine with EGR to see what happens to the engine oil in a realengine when exposed to high temperatures. During the tests oil samples have been taken andanalysed for important parameters.As a complement to these engine tests some laboratory oxidation testing have also beenperformed, to be able to compare engine test data with laboratory tests.One goal of the project was to try to formulate an empirical oxidation model, which would beable to predict oil oxidation levels in an engine, given any running parameters.
Betydelsen av hästens hud och päls för reglering av kroppstemperatur i kyla ? vad händer vid klippning och täckning?
The horse is a homeothermic animal and to keep a constant body temperature in winter season is important. Acclimatisation is to provide means for a good thermal insulation consisting of skin, hair, and an outer air layer. The skin covers the horses body and it is composed of three main layers where the top layer of the epidermis consists of dead keratinized cells that are constantly being sheed. The dermis is composed of collagen connective tissue that give the skin its strength. The bottom layer with subcutaneous fat provides a thermal insulation and can be used as an energy reserve in cold weather.
Tillämpning av en markprofilmodell för hydrologiska beräkningar i avrinningsområdesskala
There is a great need to reduce nutrient leaching from arable land into lakes and oceans. By using several different types of models it has previously been possible to describe nutrient losses in a catchment area with a minimum unit of sub-catchment level. At present, it is instead desirable to model a smaller catchment with an opportunity to re-connect the results to the corresponding fields in the catchment. Such models already exist but they are not fully able to properly describe Swedish conditions and land characteristics in our region.With the approach of creating such a model, SLU has developed a project with this work as its first stage. The model is expected to be created under the working name SWE-model which stands for Soil Water Environment and is in this first stage supposed to apply the SOIL model in catchment scale. During the procedure to describe the first step in the process of developing such a model adapted to Swedish conditions and which works in the catchment scale with an area of about 10-30 km2, focus has been set on calculating the transport of water flow from different hydrological response units. Regardless of the processes occurring in the soil after the water has been added, it is assumed that all the water which flows from each simulated unit is drained.In the first step the hydrologic response units were identified based on land use and soil type in the study area. With the help of a script with functions that retrieve and transform data, certain units were chosen for simulation. The script was also created in this project. Finally, the model results were aggregated and summarized for each unique unit, for each sub-catchment, and also for the whole catchment.From the results it is possible to see similarities in the flow dynamics between modeled and measured data. The efficiency coefficient has been calculated to correspond to the mean of the measured values for the whole simulation period. With an automated calibration process the model should be able to perform better. The volume error gives an indication of overestimation from the model..
Att spegla sin omvärld ? En exemplifierande fallstudie av Haninge kommuns biblioteksverksamhet
The purpose of this paper is to investigate in which aspects the public library is affected by its local community. This is re-searched by means of an exemplified case study of a Swedish public library in which we analyze governing documents and the library website with respect to environmental scanning and mar-keting of library services.The research questions are: How are the local community?s demands on the public li-brary being described in the governing document? How is the public library?s response to the demands of the local community being described in the operational plan? How are the demands of the local community, as shown in the governing document and the operational plan, re-flected in the marketing of library services on the library website?Our conclusions are that:The demands of the local community are described in a general fashion in the governing document, but there is a lack of concrete political guidelines.The public library's response to the demands of the local commu-nity is described to some length in the operational plan, but not with respect to economical factors.The demands of the local community are reflected to some length in the marketing of library services on the library website. Many of the overall themes that we identify in the governing document and the operational plan can be found in the marketing directed towards important target groups..
Utveckling och produktion av system fo?r ma?tning samt loggning av temperatur i roterande elektriska maskiner
The purpose of this thesis has been todesign an electric circuit that measurestemperature in three different ways. Asoftware was also designed to record andanalyse the measurments. The result of thecircuit was a PCB with inputs for 42sensors of both surface and non-surfacemeasurments. These all have a maximumerror of ±3°C..
Sjukvårdspersonals upplevelser av att använda bedömningsinstrument på barn (Pediatric Early Warning Score)
AbstractThe aim of the studie was to investigate if the Pediatric Early Warning Score system, PEWS, is an useful instrument on a children's inpatient ward, regarding the detecting of deterioration in children's vital signs. For this, a quantitative descriptive design with qualitative elements was used. Method: Study specific questionnaires were distributed to 86 persons (helpnurses, nurses and doctors). Of these, 36 answered and sent back the surveys. Results: Of 36 responses 25 felt experienced a faster detection of deterioration of vital signs in the child.
Analys av mätdata från nätstationer
Fortum has in a pilot project installed metering equipment with wireless communication in secondary substations in Stockholm. So far, the collected data are used only in specific projects.This master thesis was carried out at Fortum Distribution AB in Stockholm during 2013. The purpose of this study is to simplify and enhance the use of data in for example network planning process, by giving suggestions on how data can be managed and giving examples of analyzes that collected data can be used for.The electricity meter which Fortum has installed is a EDMI-Mk10A which is set to measure max/average/min values with a one hour time resolution of the following parameters: voltage (per phase), current (per phase) andactive power and active and reactive energy.In order to analyze the collected data an analysis tool is required. During this thesis two customized tools in Microsoft Excel have been developed, one for sorting data and one for analyzing.One aim of the thesis is to show examples of what collected measurement data can be used for. This work shows an example of analysis of active power, power factor, voltage, occurrence of interrupts and the relationship between outdoor temperature and power.This master thesis has among others resulted in the following advice: Expand the number of secondary substations with measuring equipment.
Luftfuktighetens påverkan på konstruktion och klimat i en berghangar
Aeroseum is an aviation museum located in an old military underground hangar. The ventilation system in the hangar is designed for the military purpose of the hangar. This design includes a solution with air flowing through the space between the construction of the hangar and the rock surface. The solution is intended to avoid a buildup of inflammable gases. This design leads too high humidity levels in the hangar.
Konstruktion av patientsimulator för anestesimaskiner
A patient simulator for testing anaesthesia machines has been developed at Maquet Critical Care AB, to reduce costly and time-consuming experiments on animals. The device simulates human lungs regarding lung dynamics and volume, uptake of anaesthetic agents and the production of carbon dioxide, heat and moisture. Further demands on the simulator are durability and size; the device shall be compact enough to be moveable.The resulting simulator fulfils the requirements and enables better repeatability and ability to test extreme cases than experiments on animals do.Uptake of the anaesthetic agent is achieved in a active carbon filter and controlled by regulating the flow. The flow is created by a regenerative blower and controlled using a proportional valve. The uptake can be set by the user or by a simple uptake model modified to recursively handle changes in the concentration of anaesthetic agent.Carbon dioxide is fed into the system from a tank by a mass flow regulator.