Sök:

Sökresultat:

6 Uppsatser om Sveby - Sida 1 av 1

Standardisering av brukarrelaterade indata för energiberäkningar på kommersiella lokaler

In this thesis, input data for energy performance calculations on commercialpremises have been studied. In energy performance calculations, where internal heat gain parameters are unknown, template values that, in a reasonable way represent the activity in the room, are necessary. These values can be used as input data for whole-year calculations, or for calculations on shorter periods of time.The purpose of the Sveby project is to create standardized work practice in energy issues for the construction industry. The work in this thesis is conducted to correlate with the purpose of the Sveby project, with aims of contributing with information and guidelines for the continuing work with commercial premises.In this report, suggestions for template values for internal gains parameters, based on research and calculations in the field are presented. Suggestions on how these can be implemented in a user-friendly way for two energy performance calculation software are also given, VIP Energy and IDA ICE.

Energibalansberäkning för flerbostadshus : projekterad energianvändning jämfört med beräknad energianvändning med uppmätta värden för Gävle Strand Etapp 1

Den beräknad mängd energi en byggnad gör av med på ett år visar huruvida den bidrar till ett hållbart samhälle eller inte. AB Gavlegårdarna arbetar inte enbart med att projektera fram förslag till lösningar för framtidens bostäder utan riktar även in sig på sitt nuvarande bestånd när det kommer till energianvändning i flerbostadshus. Gävle Strand Etapp 1 stod klart 2008 med ett bestånd av tolv byggnader som är gestaltade på fyra olika sätt. Alla med olika förutsättningar där främst brukarnas beteende såsom förbrukad mängd tappvarmvatten och hushållsel varierar kraftigt.Under projekteringsfasen anlitades en konsult för att beräkna den köpta energin som dessa bostäder skulle använda och kom fram till en energianvändning på 92 kWh/m2,år. Gavlegårdarnas egna beräkningar som utgick ifrån de verkliga värden som uppmättes för varje lägenhet visade i september 2009 ett medelvärde för hela beståndet som låg på 114 kWh/m2,år.AB Gavlegårdarna vill gå till botten med de problem och den extra kostnad som Gävle Strand Etapp 1 har gett upphov till genom ökad energianvändning, vilket medför att de vill utföra exakta beräkningar på varje byggnads energianvändning.

Kv. Cirkusängen : Studie av installationsprojekteringen med fokus på byggnadens Energisignatur

För att uppnå Boverkets och Miljöbyggnads energi- och miljökrav finns ett intresse av att förstå fastigheters energianvändning. Fastighetsföretaget Humlegården har uppfört ett nytt huvudkontor för bankföretaget Swedbank: kv. Cirkusängen i Sundbyberg, Stockholm och Humlegården har ett intresse av långsiktig driftförvaltning och optimering av fastighetens energisystem.Detta examensarbete undersöker den manuella (statiska) och dynamiska energiberäkningen av kv. Cirkusängen med fokus på den dynamiska modellen i energi- och inomhusklimatsimuleringsprogrammet IDA ICE. Syftet med examensarbetet är att definiera kv.

Utredning av fastighetsel i ett äldre och ett ombyggt flerbostadshus i Gävle

The residential and service sector in Sweden accounts for approximately 38% of the total energy usage and Sweden has an aim to reduce the total energy use by 20% by 2020 compared to 2008, which means residential sector will have to improve energy efficiency. As part of that a law was instituted by the Swedish parliament that all properties must have an Energy Performance Certificate (EPC) to thereby give the property owners a greater insight into energy use in their buildings and propose recommendations for energy-efficiency measures. On the EPC, a value on the building's energy performance in terms of energy use in kWh / m2 per year is declared, of which electricity is a share of it. Instructions on what to include in the amount facility electricity for running the facilities is regulated by the authority for building, Boverket while Sveby has made an interpretation of the regulations in their report "Brukarindata bostäder" where they have a table on what should be included in the amount and what not to include.This report is a study of two similar apartment buildings, where one of the buildings recently underwent renovation, to see if the declared amount of energy for electricity, in the EPC, is consistent with the measured value, and whether there has been any reduction in facility electricity in the renovated building after the renovation.The result shows that the measured value of the building electricity was 2.6 kWh / m2 per year, 28,8 %, lower than the declared value in the building that have not undergone a renovation. Calculation of values from previous years (2011) by the same percentage of facility electricity as in the results of the measurements, 56.7%, it becomes clear that the declared value for facility electricity in the EPC of the renovated building do not correspond with reality and that there has been an increase in use of facility electricity after the renovation..

Analys av Termodeck som ett uppvärmningssystem : En jämförelse mellan uppmätt och simulerat värde samt analys om skillnaden för husets energianvändning

Ett passivhus är byggt av stomentreprenör företaget Strängbetong i Vara med ventilation och uppvärmning i samma system som kallas för Termodeck. Uppvärmningen sker genom att tilluft från ett FTX-aggregat förs igenom håldäcksbjälklag som värmer upp bjälklaget. Med det erhålls ett ?värmegolv och värmetak?. För ett sådant system behövs en byggnad med tung betongstomme.Energibalans beräkning har gjorts med IDA program och schablon värden från olika kravspecifikationer som visar simulerade värden.

Inverkan av värmesystem på termisk komfort i ett flerbostadshus med hänsyn till energianvändning

Inomhusklimatet har en avgörande roll för människans hälsa och välmående då människor befinner sig inomhus i nästan halva sitt liv. Det finns flera aspekter till hur det ska erhållas ett bra inomhusklimat men de mer betydelsefulla aspekterna är både god luftkvalitet och termisk komfort. Samtidigt som innebörden av reducering av energianvändning har en viktig roll i dagens utveckling. Då det ständigt arbetas med att försöka reducera energianvändningen i syfte till att underlätta för miljö- belastningen, väcker det frågor om hur den termiska komforten påverkas av detta.Rapportens syfte kommer därmed ligga i identifikation av uppvärmningssystem för ett givet flerbostadshus i Stockholmsområdet med fokus på termisk komfort och energianvändning. Utvärderingen baseras på olika typer av inverkan från diverse system som har utförts med beräkningssprogrammet IDA ICE.