Sök:

Sökresultat:

685 Uppsatser om Solar heat - Sida 6 av 46

Datormodellering av en värmelagrande betongväggs inverkan på det termiska klimatet i ett växthus

This report describes the building of a computer model that makes it possible to simulate the thermal climate in a greenhouse. The computer model is built on the physical theory of heat exchange that occur in a greenhouse, such as radiation and convective heat exchange. The model also includes the heat storage that is active in a greenhouse.The computer model is used to simulate the thermal climate in a greenhouse under three periods, winter, spring and summer. It also investigates which effect a concrete wall has on the thermal climate in a greenhouse. The purpose of putting a concrete wall in the greenhouse model is to investigate the possibility to store heat during the day and then use this heat when the temperature drops during the night.The result from the simulations shows that a concrete wall levels the big difference in temperature that normally occurs under a day in a greenhouse.

Värmepumpars inverkan på elkvaliten

Modern technology and fast development of heat pumps, the hunt for savings in energy consumption and the strive for environmentally friendly energy sources, convenience, and financial profit, have made heat pumps a reasonable alternative for the heating of houses.When the heat pump starts it will consume a considerable amount of current, which may result in a short-lived voltage-drop if the power grid is weak compared to the start-up current.The company Fortum Distribution which owns and administrates electrical network is interested in an investigation that deals with heat pumps affect on the quality of electricity.The purpose of this investigation is to study fast electrical fluctuations (flicker) as a result of start-up currents for single as well as multiple heat pumps on the same electrical station and from this evaluate whether there will be any problems installing heat pumps..

Värmestyrning I Handske

This rapport is result of a project. The purpose of which was to design a circuit that is used in a heat glove. The heat glove is the technical aid which provides heat inside a glove.It is specially suited for old people who have problems with cold hands because of decreased blood circulation.There already was an old circuit in the glove that gives a constant current which develops heat from battery to glove through a circuit. The temperature is between 32 and 34 degrees.The problem with the existing circuit was to regulate the temperature. There is only on/off switch and there is no way to adjust desirable value of the temperature.In order to solve the problem the old circuit was investigated.

Solel till Akademiska sjukhuset : möjlig genererad effekt och solcellers estetiska konsekvenser

Today many buildings and it´s nearby surroundings are designed to achieve some kind of environmental goal.The issue concerning energy consumption is currently at focus and it is relevant that we start increase the share of renewable energy. Solar energy is an infinite resource and should therefore be considered when selecting an energy supplier. Uppsala University hospital is facing major restructuring when parts of the existing buildings will be refurbished and a large new building will be constructed. White Architects have developed a study concerning the new building and for some of the existing buildings on the hospital campus. Uppsala County requires tough energy measures and wants the new building to be classified as an eco-building in Whites following work. The classifications will involve high energy source requirements. This work has been conducted to see if solar power can be envisaged as a supplementary energy source for the University hospital and also to investigate the aesthetic impact of solar cells on the new building.

Sveriges potential för elproduktion från takmonterade solceller : Teoretisk, teknisk och ekonomisk analys

The Swedish potential of electricity production from roof mounted solar panels has been determined in three steps: accessing the existing roof top areas, simulating the amount of electricity solar panels can produce on these areas and finally analyzing how large the necessary economical change is to make the solar cells profitable.The total existing amount of roof top areas are 319 square kilometers and the area distribution follows the distribution of people. This leads to an installed power of 47,9 GW which are expected to produce 49,0 TWh electricity per year. If the quality of the electricity is prioritized the highest the power is reduced to 3,7 GW, generating 3,8 TWh yearly, but if the hosting capacity is calculated from Sweden?s total electricity need, the capacity is 42 TWh per year.Today, solar panels are not profitable in Sweden for houses, even though there is a subsidy of 35 % of the investment costs, discounted in 25 years. The profitability is calculated with a cost of capital of 5 %, a price on electricity of 1 SEK/kWh and an investment cost of 20 SEK/Wp.

Bergkyla och bergvärmeutredning för industrilokalen Rödbergsmyran 5 i Umeå, Västerbotten.

Grubbe Ventilation AB is a sheet metal and ventilation company who provides design, installation, service, and repair of ventilation. The company is expanding their business by building a new facility in Umeå, Västerbotten. The property is designed to be used for both office and industrial work.Grubbe Ventelation AB has not yet decided upon wish system which is to be established to provide the building with heating and cooling. The consulting firm Umeå Projekt Team has therefore been asked to investigate the possibilities to invest in geothermal- heating and cooling.If the investigation of a geothermal heating- and cooling system would provide favorable results it would be a very appropriate alternative that provides energy at low costs and are an environmentally friendly option as the energy comes from stored solar energy in the ground is provided by stored solar energy in the ground.The facility ´s heating and cooling consumptions are calculated in the program BV2 and the result indicate a heating demand of 185 000 kWh per year due to thermal transmittance, transmission losses, heating of warm water and a cooling requirement of 5500 kWh.Three different systems of geothermal heating and cooling were tested in the computer program Energy Earth Design. The results show no difference in the dimensioning of the drill hole if merely heating were to be used or both heating and cooling were to be established.

Inventering av värmelager för kraftvärmesystem

When a combined heat and power plant produces heat and power it often faces a deficit of heat load during the summer or other periods of time. This heat is often unnecessarily cooled away or the power production has to be reduced or shut off. If it is possible to store heat from periods with low heat demand to periods with high heat demand one can get many benefits. Among these benefits are: increased power production, decreased operation with partial load, uniformly distributed load.To be able to store heat in situations like this long-term thermal heat storages are needed. In this thesis five different types of stores are presented: rock cavern storage, tank storage, pit water storage, borehole storage and aquifer storage.

Värmeåtervinning på förskolan Rymdattacken 1 : En jämförelse av värmeväxlare

In the spring of 2014 Sweco Systems AB were commissioned to design a ventilation system for a newly built preschool in Linköping. Terms from the client was that it cost efficiency would cope with the energy demands that are placed on the building. The unit chosen was a cross-flow heat exchanger, and this work is to compare it with two other heat exchangers to see if a more energy and cost efficient could have been chosen. The heat exchangers that was chosen for the comparison was a rotating- and a counterflow heat exchanger. Simulations have been made to the different heat exchangers by the manufacturers.

Enegiutredning Hotell Princess

This report will show the energy usage of Hotel Princess in Sandviken, Sweden. When the hotel changed owner an examination of the hotels heating, ventilation and sanitary systems were done. The report showed flaws in the ventilation system, and is why the new owner wanted a closer look at the energy use of the hotel. The original building was built in the 1930s and two major extensions have been built, one in the 1950s and the most recent in the 1980s. An assumption made is that the building parts were built to the restrictions during the time. Activities on the hotel include sleep over, conference, night club, massage and swimming in the hotels pool section.

Samkörning mellan värmepumpar och fjärrvärme : Bostadsrättsföreningen Bogården

This diploma work covers an investigation over the heat - and hot water systems of thetenant-owner's association, Bogården. The heat - and hot water needs of Bogården aresatisfied by both district heating as well as three heat pumps. Implemented investigationshows that the heat pumps are not used in a profitable way. Apart from that, the reservepossibilities are small. There is also a risk of the growth of Legionella bacterium in thehot water system.Since the heat pumps are already installed, HSB-Gävleborg (responsible for Bogården)has a wish to investigate possible proposed actions for optimization of existing plant.After completed investigation, a new proposed action is presented.

Systemlösningar för plus- eller passivhus : En studie med syftet att lösa energibehovet för ett specifikt hus.

The purpose of the house which is the basis of this report is to be able present itself on the market as a relatively cheap and at the same time a climate friendly choice. The house is supposed to be able to be built anywhere in Sweden and the rest of Scandinavia in a short period of time. This puts demand on what kind of heating system the house can have, since not all places have the geographic advantage of being able to use geothermal or district heating. Therefore the heating system choices will only include those that are not limited by their geographic location. The house will be built in modules which only require the groundwork to be done before the house can be erected. In this report "System solutions for plus or passive-housing" a comprehensive literature search has been conducted as well as a number of calculations.

Undersökning av solcellspotentialen för golfverksamheter i Sverige

Photovoltaic Systems in Sweden has longbeen heavily dependent on subsidies and grants to bring in a profit for the investor. Production of excess electricity is a major reason for this as the compensation for excess electricity today is low. However, there are businesses that have an electricityneed that are particularly suitable for solar electricity. These businesses have an electricity demand when the sun shines the brightest and if the Photovoltaic System is properly scaled, the excess electricity can be minimized. A golf club is that kind of a business and this thesis aims to examinate the solar power potential for golf businesses in Sweden.Nine golf clubs was selected from different locations in Sweden.

Upplevda barriärer för clean technology-företag - Fallstudier om kommersialisering av produkter på en internationell marknad för solenergi

Overall aim of this master?s thesis is to describe and identify perceived barriers in Swedish businesses within solar energy field and analyze, based on four theoretical viewpoints, how these barriers can be handled. In other words how can the barriers be overcome or eliminated to better succeed in the commercialization process? The method applied is qualitative in which data has been collected through phone interviews originated from seven Cleantech businesses which operate within solar energy. Furthermore this thesis has a descriptive- and an explorative purpose.

Lågtempererad fjärrvärme i Umeå

People in today?s society are becoming more and more aware of how important it is to use energy as efficiently as possible. This is clearly noticeable by an increase in home produced heat with e.g. solar panels or heat pumps heating systems. These changing customer demands forces district heating technology to be redesigned, which is why there is an ongoing research regarding the next generation of district heating - low temperature district heating (LTDH).

Asymptotiska egenskaper hos vissa kombinatoriska strukturer

In an attempt to develop a more cost-efficient material for solar   energy applications, nano-particles of nickel oxide composite in a silikatmatris manufactured with solar gelmethod and studied structurally by electron microscopy. Furthermore, the thin film optical properties characterized by Variable. Angel Spectroscopic Ellipsometry. Sol gelfilms suitability as a selective absorber surface is also analyzed by optical modeling..

<- Föregående sida 6 Nästa sida ->